• Title/Summary/Keyword: 모세관 한계

Search Result 23, Processing Time 0.018 seconds

Theoretical Analysis on the Heat Transport Limitation of a Sintered Metal Wick Heat Pipe (소결윅 히트파이프의 열수송 한계에 관한 이론적 해석)

  • Kim Keun-Bae;Kim Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.4
    • /
    • pp.16-25
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitation of a copper powder sintered wick heat pipe was performed. The heat pipe diameter was 8mm and water was used for working fluid. The particle diameter was classified by 5 different meshes, and each capillary pressures and heat transport limitations. thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius($r_c$), porosity($\varepsilon$), Permeability (K). The wick capillary limitation was increased according as the particle diameter and the wick thickness and the operating temperature were increased. As the porosity and the capillary radius were larger. then the heat transport limitation was higher. The thermal resistance was greatly increased according as the wick thickness was increased.

Comparison of the Heat transport Limitations for Screen Mesh Wick and Sintered Metal Wick Heat Pipes by Theoretical Analysis (이론적 해석에 의한 스크린 메쉬윅과 소결윅 히트파이프의 열수송 한계 비교)

  • Kim Keun-Bae;Kim Yoo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.267-274
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitations of screen mesh wick and sintered wick heat pipes was performed. The heat pipe diameter was 8mm and water was used for working fluid. For the 250 mesh, each capillary pressures and heat transport limitations, thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius (r$\_$c/), porosity ($\varepsilon$) and permeability (K). The wick capillary limitation was increased as the operating temperature and the wick thickness were increased, and generally the sintered wick showed higher heat transport limitations than that of the screen wick. The thermal resistance of the screen wick was higher than that of the sintered wick and both thermal resistances were linearly increased as the wick thickness was increased.

Analysis of Heat Transport Limitations of the Heat Pipe for Structural Characteristics of Sintered Metal Wick (소결윅의 구조적 특성에 따른 히트파이프의 열수송 한계 분석)

  • Kim, Keun-Bae;Kim, Yoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.97-103
    • /
    • 2005
  • In this paper, effects on the heat transport limitation of heat pipe by the wick structural factors were theoretically analyzed for the sintered-copper wick heat pipe. Uniformity of particle size and sintering process were acted as dominant factors on the pore distribution and wick porosity, and small deviations of the wick thickness and the pore size greatly affected the heat transport limitations of the heat pipe. Especially, slight variations of the wick thickness, mean particle radius and capillary radius along the vapor temperatures and inclination angles remarkably changed the capillary limitation of the heat pipe.

A Study on the Capillary Limitation in Copper-Water Heat Pipes with Screen Wicks (스크린 윅을 삽입한 동-물 히트파이프에서 모세관 한계에 관한 연구)

  • 박기호;이기우;노승용;이석호;유성연
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1023-1030
    • /
    • 2002
  • This paper is to research the heat transfer characteristic performance of the copper-water heat pipe with the screen wicks. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size has been much smaller. As a result, a high-performance cooling system is needed. Experimental variables are inclination angles, temperatures of cooling water and the mesh number of screen wicks. The distilled water was used for the working fluid. At the inclination angle $6^{\circ}$ in top heat mode, the two layers of the 100-mesh screen wick showed the best heat transfer performance. The thermal resistance of the two layers with the 100-mesh screen was 0.7~$0.8^{\circ}C$/W.

Effects of the Sintered Wick Characteristics on the Heat Transport Limitations of the Heat Pipes (소결윅 특성이 히트파이프의 열수송 한계에 미치는 영향)

  • Kim, Keun-Bae;Kim, Yoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.127-135
    • /
    • 2006
  • Experimental studies of the cylindrical sintered-copper wick heat pipes were carried out to investigate the capillary heat transfer characteristics. Six models of the sintered-copper wick heat pipes were manufactured and tested to evaluate the heat transport limitations and the thermal characteristics. Also the performance of the heat pipes was analyzed theoretically and compared with the test results. The heat pipe models are divided into two sintered-wick groups and the nominal particle sizes are $180{\mu}m$(wick #1) and $200{\mu}m$(wick #2) respectively The experimental results showed that, the porosity of wick #1 was higher than that of wick #2, and also the wick #1 was generally superior than the wick #2 for the heat transport capability. The maximum heat transport rates were increased as the wick thicknesses and the vapor temperatures were increased.

A Study on the Development of Electrolysis System with Vertically Circulating Mercury Capillary Bundle Electrode and its Characteristics (수직형 순환식 수은 모세관 다발체 전극 전해계의 개발과 그 특성 연구)

  • Kim, Kwang-Wook;Lee, Eil-Hee;Shin, Young-Joon;Yoo, Jae-Hyung;Park, Hyun-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.228-236
    • /
    • 1996
  • An electrolysis system with a vertically circulating mercury capillary bundle electrode was developed with a very large electrode area in a minimum space. This system was operated by forcedly feeding mercury and aqueous solution containing metal ion into a fiber bundle packed densely within a small porous glass tube. In order to test the characteristics and stability of the electrolysis system, the reduction voltammograms of uranyl and ferric ions were measured with changes of the mercury flow rate and the aqueous flow rate. The aqueous flow rate had a large effect on the electrochemical reaction of metal ion occurring at the interface between the mercury and the aqueous solution and had to be regulated as an appropriate value to have a good limiting current shape. The limiting current was linearly proportional to the aqueous flow rate, and complete reductions of uranyl and ferric ions were rapidly and continuously accomplished at the potential showing limiting current. With a mercury flow rate high enough to keep a capillary continuum of mercury in the fiber bundle, the mercury flow rate had almost no effect on the electrochemical reaction. This system was confirmed to be effective and stable enough to control rapidly and continuously the oxidation state of metal ions fed into the system under an appropriate aqueous flow rate.

  • PDF

A Sensitive Detection of Actinide Species in Solutions Using a Capillary Cell (모세관 셀을 이용한 수용액 내 악티나이드 화학종의 고감도 검출)

  • Cho, Hye-Ryun;Park, Kyuong-Kyun;Jung, Euo-Chang;Song, Kyu-Seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.109-114
    • /
    • 2009
  • Absorption spectra for a quantitative analysis of actinide elements such as U(VI) and Pu(V) were measured by using a liquid waveguide capillary cell (LWCC) which has an optical path length of 1.0 meter. In order to investigate radioactive elements, a LWCC is installed in a glove box and is coupled to a spectrophotometer with optical fibers. Limits of detection (LOD) for the system were determined as 0.74 and 0.35 M with molar absorption coefficients of 8.14${\pm}$0.07 (414 nm) and 17.00${\pm}$0.16 (569 nm) $M^{-1}cm^{-1}$ for U(VI) and Pu(V) ions, respectively. The measured LOD values are about 30 times more sensitive when compared to those achievable by using a conventional quartz cell with an optical path length of 1.0 cm. As an application with an enhanced sensitivity, a quantitative analysis for micromolar concentrations of Pu(V) has been performed to decrease the uncertainty in the formation constant of the Pu(VI)-OH complex.

  • PDF

Suspended Solid Removal using Capillary-syphon Phenomenon -Evaluation of Possibility for Adapting Water Supply Process- (모세관 사이폰 현상을 이용한 부유물질 제거 - 상수처리공정 적용 가능성 평가 -)

  • Park, Dong-keun;Kim, Su-jung;Lee, Hae-goon;Jang, Jung-kuk;Han, Kee-baek;Kim, Chang-won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1285-1294
    • /
    • 2000
  • In this study, we investigated the possibility of the elimination of suspended solid and the factors affecting effluent water quality, and the amount of treated water, using the SS removal equipment adapted capillary-syphon phenomenon. Treated water quantity decreased as the accumulation time and the increase of head of capillary syphon, whereas the effluent water quality was improved. At coagulant dosage 0, 0.45, $1.82mg/{\ell}$ (as $Al^{+3}$) and limiting flux $107{\ell}/m/day$. turbidity of treated water was 2, 1, 0.5 NTU in each case. During operating period 15~17 days, the amount of washing water was just used 0.5~0.7% of the amount of treating water. So it is expected that coagulation & sedimentation and rapid filtration process can be replaced with the SS removal equipment adapted capillary-syphon phenomenon in water purification process.

  • PDF

Operational Characteristics for a Miniature Heat Pipe with a V-shaped Groove Wick (V형 그루브윅을 갖는 소형 히트파이프의 작동특성)

  • 강환국;김철주;홍성은
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.197-205
    • /
    • 1999
  • 소형 히트파이프에서 ?을 구리망사 또는 그루브를 적용할 수 있고 그루브 형상은 U, V 등 다양하다. 망사?은 모세압이 큰 잇점이 있어나 제작 단가가 높다. 그루브?은 대량생산이 용이하나 전밀 가공 기술이 요구된다. 현재까지 국내에서는 노트북 PC의 CPU 냉각에 사용한 소형 히트파이프의 전량을 해외에서 구매하고 있다. 본 연구에서는 직경 7 mm U형 그루브 관을 인발하여 관직경을 축소한 결과 내경 3.6 mm의 외경 4mm 의 V형 그루브관을 얻을 수 있었다. 이 관을 이용하여 소형 히트파이프를 제작하고 열전달 성능 시험을 수행하였다. 열전달 한계는 40~6$0^{\circ}C$ 범위작동온도 경사각 0$^{\circ}$ 에서 3 W를 얻을 수 있었다. U형 그루브 히트파이프에 비하여 모세압 저하로 인하여 낮은 값을 나타내었다. 열저항을 약 0.7~l.3 $^{\circ}C$/W 로 U형 그루브와 유사하였다.

  • PDF

Theoretical Analysis of Heat Pipe Thermal Performance According to Nanofluid Properties (나노유체 특성에 따른 히트파이프 성능해석)

  • Lim, Seung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.599-607
    • /
    • 2015
  • In this study, we theoretically investigate the thermal performances of heat pipes that have different nano-fluid properties. Two different types of nano-particles have been used: $Al_2O_3$ and CuO. The thermal performances of the heat pipes are observed for varying nano-particle aggregations and volume fractions. Both the viscosity and the conductivity increase as the volume fraction and the aggregation increase, respectively. Increasing the volume fraction helps increase the capillary limit in the well-dispersed condition. Whereas, the capillary limit is decreased under the aggregate condition, when the volume fraction increases. The dependence of the heat pipe thermal resistance on the volume fraction, aggregation, and conductivity of the nano-particles is analyzed. The maximum thermal transfer of the heat pipe is highly dependent on the volume fraction because of the high permeability of the heat pipe. For the proposed heat pipe, the optimum volume fraction of the nano-particle can be seen through 3D graphics.