• Title/Summary/Keyword: 모서리각

Search Result 126, Processing Time 0.026 seconds

Analysis of Electromagnetic Scattering by a Perfectly Conducting Strip Grating on Dielectric Multilayers (다층 유전체 위의 조기적인 도체 스트립 구조에 의한 전자파산란 해석)

  • 윤의중;양승인
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.2
    • /
    • pp.161-172
    • /
    • 1997
  • In this paper, electromagnetic scattering by a perfectly conducting strip grating on dielectric multilayers is analyzed for the normalized reflected and transmitted power by applying the Fourier-Galeakin moment method. The induced current density is expanded in a series of multiplication of chebyshev polynomials of the first kind and functions with appropriate edge boundary condition, the continuous condition of electromagnetic field is applied in the boundary planes. The confirm the validity of the proposed method, the nor- malized reflected and transmitted power obtained by varying the relative permittivity and thickness of each dielectric layers are evaluated and compared with those of the existing numerical method and a paper, and then the numerical results in this paper are in good agreement with those of the existing numerical method and the paper. The sharp variation position in the geometrically normalized reflected and transmitted power can be moved by the incident angle, grating period, and the relative permittivity and thickness of the dielectric multilayers, these sharp variation points which are called the Wood's anomaly of the Geome- trically normalized reflected power are observed as a main factor when the reflected powers of the higher order mode are transitted between propagating and evanescent modes, and the local minimum positions are slightly moved to the left hand direction in which grating period is getting small according to the increase of the relative permittivity of dielectric layers.

  • PDF

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

A Study on the Behavior Characteristics of Large Deep Foundations (대형 깊은 기초의 지지거동 특성에 관한 연구)

  • Park, Choon-Sik;Jung, Kwang-Min
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.83-91
    • /
    • 2020
  • In this study, the characteristics of support behavior according to the change of ground condition of the cast-in-place pile and the large Caisson foundation, which are increasingly used as foundations of large structures and bridges. the allowable bearing capacity calculated using the yield load analysis method was analyzed to calculate similar allowable bearing capacity for each method. In addition, the allowable bearing capacity calculated by the ultimate load analysis method was found to have a large difference in bearing capacity for each method. Through this point, it can be usefully used as an empirical formula for evaluating the settlement characteristics of piles in future design and construction. In addition, as a result of examining the ground force distribution during sedimentation of large caissons, the section of the weathered rock layer showed almost constant ground force distribution as ground forces decreased after yield occurred at the base corner. And in the bed rock layer section, the foundation's center was transformed into a ground force in the form of a convex downward due to an increase in the ground resistance of the central part. Using these results, the theory previously presented by Fang (1991) and Kőgler (1936) was proved.

Evaluation of the Stability of Ipseok-dae Columnar Joints in Mudeungsan National Park Using 3DEC (3DEC을 이용한 무등산국립공원 입석대 주상절리대의 안정성 평가)

  • Noh, Jeongdu;Kang, Seong Sueng
    • The Journal of Engineering Geology
    • /
    • v.32 no.3
    • /
    • pp.351-361
    • /
    • 2022
  • Numerical analysis performed to predict the behavior of Ipseok-dae columnar joints in Mudeungsan National Park to understand their stability and movement. The numerical analysis technique, 3DEC, is based on the discrete element method that can analysis discontinuities. The analysis used data for material properties derived from laboratory tests, which found that average density was 2.68 kN/m3, average normal stiffness was 3.15 GPa/m, average shear stiffness was 1.00 GPa/m, average cohesion was 0.51 MPa, and the average friction angle was 33°. The Ipseok-dae columnar joints were modeled on the basis of the field survey data for 15 joints located between the observation platform and the hiking trail. The numerical analysis assessed the behavior of each columnar joint by interpreting the displacement of the edges of its upper and lower surfaces. The greatest maximum displacement was found in columnar joint No. 6, and the greatest minimum displacement was found in joint No. 11. Analyzing the movements of five discontinuities in joint No. 11 indicated that the maximum displacement occurred at the 2nd level. The other levels were ordered 5th, 4th, 1st, and 3rd in terms of subsequent greatest displacements. Considering the total displacement in the 15 studied joints, the Ipseok-dae columnar joints are judged to be stable. However, considering the cultural and historical value of Mudeungsan National Park, it is regarded that the currents slope stability should be maintained by monitoring the individual rock blocks of the joints.

Experimental Study on Two-Seam Cold Formed Square CFT Column to Beam Connections with Asymmetric Diaphragms (상하 이형 다이아프램으로 보강된 2심 냉간성형 각형 CFT 기둥-보 접합부의 실험적 연구)

  • Oh, Heon Keun;Kim, Sun Hee;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.35-45
    • /
    • 2013
  • The concrete-filled tube column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. It suggests that pipe should be produced by welding two sides together where two shapes are joined after a channel is pre-welded onto the three sides in order to form an internal diaphragm. The upper diaphragm of the connection used the horizontal plate and the lower diaphragm used the Vertical plate. This research performed 6 monotonic tension experiments describing the connection upside and downside in order to evaluate the structural capability of the offered connection. And the cyclic loading experiment was performed about 2 T-Type column to beam connections. As to the experimental result edge cutting geometry, there was no big effect. An increase in the number of holes of the plate ultimate strength was increased by 5% and The thickness of the plate increases, the maximum strength was increased by 4%. T-Type connections until it reaches the plastic moment showed a stable behavior.

A Miniaturized and Band Rejection Characteristic of Bow-Tie Monopole UWB Antenna (보우-타이 모노폴 UWB 안테나의 소형화 및 대역 저지 특성)

  • Choi, Hyung-Seok;Choi, Kyoung;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.300-305
    • /
    • 2012
  • In this paper, a miniaturized bow-tie monopole UWB antenna with band rejection characteristic is proposed. To miniaturize the proposed antenna, a perfect magnetic wall(PMW) condition is applied to primitive bow-tie monopole antenna. An uneven ground patch, a tapered feeding structure and a edge-chopped main patch are adapted for impedance matching. A quater-lambda slot resonator is inserted at main patch to prevent interference in UWB band from another band. The proposed antenna is fabricated on Taconic RF60-A substrate with relative permittivity of 6.15. The size of the proposed antenna is $30.0{\times}39.7mm^2$, which is only 45 % of the conventional bow-tie monopole antenna. The proposed antenna covers full UWB band with return losses less than -10 dB and has band stop characteristic in 5 GHz WLAN band. The maximum gains are within -1.0~5.0 dBi, the group delay variations are within 1.0 ns and the radiation patterns show directivity characteristics in x-y plane.

Characteristics of Edgetones by Jet-Cylinder Interaction (분류와 원통에 의해 발생하는 쐐기소리의 특성)

  • 한희갑;김승덕;안진우;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.235-239
    • /
    • 1996
  • 분류가 모서리에 충돌할 때 발생하는 순음성 소리인 쐐기소리(edgetone)는 공력음향의 대표적인 현상으로서 지금까지 수많은 연구가 있어 왔으며 그 대부분의 특성이 규명되었다고 할 수 있다. 쐐기소리의 발생기구인 되먹임(feedback) 이론을 처음으로 제안한 이는 Powell로서 그는 되먹임사이클의 위상조건에 의하여 주파수특성에 관한 모델을 제안하였으며, 최근 그 모델의 위상인자에 관하여 Kwon은 새로운 값을 제안한 바 있다. 그런데, 쐐기소리의 이론은 주로 분류가 쐐기나 벽에 충돌할 경우에 집중되어 왔으며 분류가 원통에 충돌하여 발생하는 경우에 관한 연구는 Krothapalli의 초음속분류에 관한 연구와 Mochizuki등의 아음속분류에서 원통지름의 영향에 관한 연구를 들 수 있을 뿐이다. Mochizuki등은 원통의 지름이 노즐의 높이보다 작은 경우에 쐐기 소리의 주파수가 원통의 와류이탈(vortex shedding) 주파수와 같은 것을 관찰하였다. 그러나 분류와 원통이 작용하여 발생하는 쐐기소리의 주파수 특성에 관한 이론적 해석을 시도한 연구는 없으며 또한 방사음장의 특성에 관하여도 Han과 Kwon에 의한 모델이 발표된 바 있으나 실험적으로 입증되지 못하였다. 따라서, 본 연구의 목적은 2 fig.1과 같이 2차원 분류가 원통에 충돌할 때 발생하는 쐐기소리의 주파수특성의 정량적인 모델을 세우고 방사음장의 지향특성의 이론 모델을 확립하는 것이다. 먼저 주파수특성을 실험하고 되먹임이론을 적용하여 분석하므로써 유효음원의 위치를 구하고 또한, 수직벽에 작용하여 발생하는 충돌음(impinging tone)의 경우를 실험하여 주파수특성을 비교 고찰하므로써 유효음원의 위치에 관한 이론을 입증한다. 아울러 원통과 평면벽의 각 경우에 방사음장의 지향특성을 측정하고 고찰한다.2,5,6]을 단계별로 고찰하여, 점점 까다로워져 가는 선박 진동규제[3,4]에 대처하고 승무원의 안락성에 대한 욕구, 구조물의 안전성, 장비의 성능보존이 만족되는 저진동 선박의 건조를 위해 향후 해결해야할 과제들을 도출하여 선박진동분야이 연구개발 방향을 제시하고자 한다. 하는 것은 진단의 정밀도에 문제가 있을 것으로 생각된다. 따라서 언어적진리치가 도입되어 [상당히 확실], [확실], [약간 확실] 등의 언어적인 표현을 이용하여 애매성을 표현하게 되었다. 본 논문에서는 간이진단 결과로부터 추출된 애매한 진단결과중에서 가장 가능성이 높은 이상원인을 복수로 선정하고, 여러 종류의 수치화할 수 없는 언어적(linguistic)인 정보ㄷㄹ을 if-then 형식의 퍼지추론으로 종합하는 회전기계의 이상진단을 위한 정밀진단 알고리즘을 제안하고 그 유용성을 검토한다. 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both

  • PDF

A Study on the Design Parameters of the Static Ring in the Ultra-high Voltage Non-uniform Electric Field (초고압 불평등 전계에서 정전링 설계변수에 대한 연구)

  • Kim, Jin-Sung;Seo, Min-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.577-582
    • /
    • 2020
  • Electricity produced at power plants is distributed to consumers through several stages of substations. At this time, an ultra-high voltage transformer is needed in the initial transmission stage to transmit a voltage suitable for each consumer. A high voltage, non-uniform electric field is formed at the end of the winding of the ultra-high voltage transformer, which carries a risk of dielectric breakdown. The winding of the ultra-high voltage transformer is an electrode, which is the key to converting the magnitude of the voltage. A non-uniform electric field is formed along the shape of the winding end, resulting in high electrical stress. The static ring installed at the upper and lower ends of the winding is used to disperse the stress at the winding end. Several variables should be considered when designing a static ring. Among them, this study examined how the curvature of the static ring, the thickness of the insulating paper, the number of barriers, and barrier thickness affect the electrical stress of the static ring using the Finite Element Method. Suggestions to be considered when designing the static ring are proposed through the FEM results.

Real-Time 3-D Ultrasound Imaging Method using a 2-D Curved Array (이차원 곡면 어레이를 이용한 실시간 3차원 초음파 영상화 기법)

  • 김강식;한호산;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.351-364
    • /
    • 2002
  • Conventional 3D ultrasound imaging using mechanical ID arrays suffers from poor elevation resolution due to the limited depth-of-focus (DOF). On the other hand, 3D imaging systems using 2D phased arrays have a large number of active channels and hence require a very expensive and bulky beamforming hardware. To overcome these limitations, a new real-time volumetric imaging method using curved 2-D arrays is presented, in which a small subaperture, consisting of 256 elements, moves across the array surface to scan a volume of interest. For this purpose, a 2-D curved array is designed which consists of 90$\times$46 elements with 1.5λ inter-element spacing and has the same view angles along both the lateral and elevation directions as those of a commercial mechanical 1-D array. In the proposed method, transmit and receive subapertures are constructed by cutting the four corners of a rectangular aperture to obtain a required image qualify with a small number of active channels. In addition the receive subaperture size is increased by using a sparse array scheme that uses every other elements in both directions. To suppress the grating lobes elevated due to the increase in clement spacing, fold-over array scheme is adopted in transmit, which doubles the effective size of a transmit aperture in each direction. Computer simulation results show that the proposed method can provide almost the same and greatly improved resolutions in the lateral and elevation directions, respectively compared with the conventional 3D imaging with a mechanical 1-D array.

Discrimination between Earthquakes and Explosions Recorded by the KSRS Seismic Array in Wonju, Korea (원주 KSRS 지진 관측망에 기록된 지진과 폭발 식별 연구)

  • Jeong, Seong Ju;Che, Il-Young;Kang, Tae-Seob
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.3
    • /
    • pp.137-146
    • /
    • 2014
  • This study presents a procedure for discrimination of artificial events from earthquakes occurred in and around the Korean Peninsula using data set in the Wonju KSRS seismograph network, Korea. Two training sets representing natural and artificial earthquakes were constructed with 150 and 56 events, respectively, with high signal to noise ratio. A frequency band, Pg(4-6 Hz)/Lg(5-7 Hz), which is optimal for the discrimination of seismic sources was derived from the two-dimensional grid of Pg/Lg spectral amplitude ratio. The corrections for the effects of earthquake magnitude and hypocentral distance were carried out for improvement of discrimination capability. For correcting the effect of magnitude dependence due to the inverse proportionality of corner frequency to seismic moment, the Brune's source spectrum was subtracted from the observation spectrum. The spectrum was corrected using the optimal damping coefficient to remove damping effect with the hypocentral distance. The effect of locally varying spectrum ratio was cancelled correcting variation of wave propagation along the ray path. The performance in discrimination between training sets of natural and artificial events was compared using the Mahalanobis distance in each step of correction. The procedure of magnitude, distance, and path corrections show clear improvements of the discrimination results with increasing Mahalanobis distance, from 1.98 to 3.01, between two training sets.