• 제목/요약/키워드: 모멘트골조

검색결과 271건 처리시간 0.023초

철골 모멘트골조로 보강된 철근콘크리트 건물의 내진성능 평가 (Seismic Performance Evaluation of Non-Seismic Reinforced Concrete Buildings Strengthened by Perimeter Steel Moment Frame)

  • 김선웅
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.233-241
    • /
    • 2020
  • This paper is to investigate the retrofitting effect for a non-seismic reinforced concrete frame strengthened by perimeter steel moment frames with indirect integrity, which ameliorates the problems of the direct integrity method. To achieve this, first, full-scale tests were conducted to address the structural behavior of a two-story non-seismic reinforced concrete frame and a strengthened frame. The non-seismic frame showed a maximum strength of 185 kN because the flexural-shear failure at the bottom end of columns on the first floor was governed, and shear cracks were concentrated at the beam-column joints on the second floor. The strengthened frame possessed a maximum strength of 338 kN, which is more than 1.8 times that of the non-seismic specimen. A considerable decrease in the quantity of cracks for the strengthened frame was observed compared with the non-seismic frame, while there was the obvious appearance of the failure pattern due to the shear crack. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be reasonably determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The proposed method had an error of about 2.2% for the non-seismic details and about 4.4% for the strengthened frame based on the closed results versus the experimental results.

합성반강접 접합부를 갖는 2차원 8층 비가새 철골골조의 동적거동 (Dynamic Behavior of 2D 8-Story Unbraced Steel Frame with Partially Restrained Composite Connection)

  • 강석봉;이경택
    • 한국강구조학회 논문집
    • /
    • 제19권5호
    • /
    • pp.503-513
    • /
    • 2007
  • 구조물의 지진응답은 구조물의 강성도에 영향을 미치는 접합부의 특성에 영향을 받는다. 본 연구에서는 합성반강접 접합부를 갖는 2차원 8층 비가새 철골구조물에 대하여 동적 비선형 해석 프로그램을 이용한 푸쉬오버 해석과 시간이력해석을 실시하여 구조물의 거동을 예측하였다. 접합부 비선형 모멘트-회전 특성, 합성보 및 철골기둥의 재료 비선형 특성을 고려하여 구조해석을 실시하였다. 합성반강접 접합부를 완전 강접합부로 이상화하면 푸쉬오버 해석에서 구조물의 초기강성도와 종국강도가 증가되었고 시간이력해석에서는 밑면전단력, 최대층간변위, 보 및 기둥에 발생되는 최대 휨모멘트가 접합부 강성 및 이력거동의 영향을 받았다. 최대지반가속도가 0.4g인 지진파에 대하여 합성반강접 구조물에서는 FEMA 273의 최대 층간변위에 대한 인명손상방지 기준을 만족하였으며 보와 기둥이 비탄성 거동을 경험하지 않은 반면 완전 강접합부로 이상화한 구조물에서는 보 및 기둥이 비탄성 거동을 경험하였다.

강구조 성능기반설계를 위한 접합부의 내진성능평가치 제안 (The Suggestion of Seismic Performance Values on Connections for Performance Based Design of Steel Structures)

  • 오상훈;오영석;홍순조;이진우
    • 한국강구조학회 논문집
    • /
    • 제23권2호
    • /
    • pp.147-158
    • /
    • 2011
  • 본 연구의 목적은 국내 강구조 성능기반설계를 위한 접합부의 내진성능평가치를 제안하는 것에 있다. 최근 성능설계에 대한 기초연구가 국내, 외에서 증가하고 있으며, 본 연구에서는 외국의 성능설계기법을 조사, 분석하여 강구조 건축물의 성능한계분류를 제안하였다. 제안된 성능한계분류에 따라 강구조에 적합한 공학량으로서 내진성능규정치를 제시할 필요가 있다. 그 첫 번째 단계로 강구조 실대형 실험을 통한 접합부의 실험결과를 중심으로 기초자료를 조사하여 작성하였다. 모멘트 골조 접합부의 실험 데이터에서 얻은 모멘트-회전각 관계를 이용하여 항복하중 이하에 존재할 것으로 판단되는 기능한계와 손상한계는 층간변형각으로 구분하였다. 또한 항복하중과 최대하중 사이에 존재할 것으로 판단되는 복구한계와 안전한계는 소성율과 누적소성변형배율을 조사하여 구분하였다.

깊이 1200mm급 변단면보의 중간모멘트골조용 내진접합부 개발 (Beam-Column Connection with 1200mm Deep Multi-Reduced Taper Beam for Intermediate Moment Frame)

  • 정시화;알미아이유 로벨 원디므;박만우;주영규
    • 대한건축학회논문집:구조계
    • /
    • 제35권4호
    • /
    • pp.135-146
    • /
    • 2019
  • Deep beam has high section modules compared with shallow beam of the same weight. However, deep beam has low rotational capacity and high possibility of brittle failure so it is not possible to apply deep beams with a long span to intermediate moment frames, which should exhibit a ductility of 0.02rad of a story drift angle of steel moment frames. Accordingly, KBC and AISC limit the beam depth for intermediate and special moment frame to 750mm and 920mm respectively. The purpose of this paper is to improve the seismic performance of intermediate moment frame with 1200mm depth beam. In order to enhance vulnerability of plastic deformation capacity of deeper beam, Multi-Reduced Taper Beam(MRTB) shape that thickness of beam flange is reinforced and at the same time some part of the beam flange width is weakened are proposed. Based on concept of multiple plastic hinge, MRTB is intended to satisfy the rotation requirement for intermediate moment frame by dividing total story drift into each hinge and to prevent the collapse of the main members by inducing local buckling and fracture at the plastic hinge location far away from connection. The seismic performance of MRTB is evaluated by cyclic load test with conventional connections type WUF-W, RBS and Haunch. Some of the proposed MRTB connection satisfies connection requirements for intermediate moment frame and shows improved the seismic performance compared to conventional connections.

비내력벽을 가진 RC모멘트저항골조의 취약도 해석 (Fragility Analysis of RC Moment Resisting Frame with Masonry Infill Walls)

  • 고현;박용구;이동근
    • 한국전산구조공학회논문집
    • /
    • 제22권4호
    • /
    • pp.355-362
    • /
    • 2009
  • 국내에 많이 건설되고 있는 빌라형 주택은 건축적인 요구를 위하여 저층부에 필로티를 두고 있는 경우가 많다. 구조물 상층부의 비내력벽에 의하여 저층에 연약층을 유발하고 따라서 지진에 매우 취약하다. 그러나 설계시 일반적인 설계방법과 동일하게 상부층의 칸막이벽은 비구조체로 간주되어 무시된다. 그러므로 설계단계에서 무시되는 비내력벽의 유무에 따라서 건축물이 어떠한 지진거동의 차이점을 보이는지 살펴볼 필요가 있다. 본 연구에서는 대상 건축물의 지진취약도 해석을 통하여 비내력벽의 유무에 따른 건축물의 지진거동을 평가하였다. 비내력벽의 유무에 따른 동일한 골조를 가지는 저층 철근콘크리트 건축물을 적용하여 지진거동에서 비내력벽의 영향을 평가하였다. 비내력벽은 보편화된 모형화 방법인 등가의 대각 압축 스트럿으로 고려하였다. 골조만 있는 모델과 연약층이 있는 모델의 취약도곡선을 비교하였다. 해석 결과로 연약층이 있는 RC 건물의 내진성능은 설계기준에서 제시하고 있는 성능수준을 만족하지 못하며 지진에 취약함을 보여준다.

토글 가새-고집적 마찰댐퍼를 설치한 철근콘크리트 모멘트 골조의 성능 평가 (Seismic Behavior of Reinforced Concrete Moment Frames Retrofitted by Toggle Bracing System with High Density Friction Damper)

  • 한상환;김지영;문기훈;이창석;김형준;이강석
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.133-140
    • /
    • 2014
  • The friction damper can be used for improving the seismic resistance of existing buildings. The damper is often installed in bracing members. The energy dissipation capacity of the damping systems depends on the type of the structure, the configuration of the bracing members, and the property of dampers. In Korea, there are numerous low- to mid-rise reinforced concrete moment frames that were constructed considering only gravity loads. Those frames may be vulnerable for future earthquakes. To resolve the problem, this study developed a toggle bracing system with a high density friction damper. To investigate the improvement of reinforced concrete frames after retrofit using the developed damped system, experimental tests were conducted on frame specimens with and without the damped system. The results showed that the maximum strength, initial stiffness and energy dissipation capacity of the framed with the damped system were much larger than those of the frame without the damped system.

다자유도 철근 콘크리트 모멘트 골조의 Steel Jacket보강 내진성능개선 (Seismic Performance Improvement of MDOF Reinforced Concrete Moment Frame Retrofitted Steel Jacket)

  • 김준영;정인규;박순응
    • 한국공간구조학회논문집
    • /
    • 제13권1호
    • /
    • pp.69-77
    • /
    • 2013
  • This study is the research appling the representative Displacement-Based Design which is the basic concept of Direct Displacement Based Design proposed by Chopra and Goel to original Reinforced Concrete moment frame and determining the thickness of retrofit Steel Jacket about the Maximum design ground acceleration, and developing the more improved Algorithm as well as program by the Retrofit Design method and Nonlinear analysis by the Performance design method before and after reinforcement appling the determined retrofit thickness. It also shows the result of the seismic performance improvement which is the ratio of seismic performance appreciation result yield displacement 19%, yield strength ratio 24%, displace ductility ratio the maximum 27% comparing Multi degree of freedom, column member of Reinforced Concrete with the performance improvement column member considering the thickness of the determined Steel Jacket. The developed Algorithm and program are easy to apply seismic design and application to the original Reinforced Concrete building, at the same time, it applicate to display well the design result of Target displacement performance level about nonlinear behavior.

철골 구조물의 제진 및 면진성능 (Damping and Isolation Performance of Steel Structure)

  • 윤현도;박완신;한병찬;황선경;이규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.221-230
    • /
    • 2004
  • 본 논문에서는 지진하중 작용시, 점탄성 감쇠기 및 면진장치를 설치한 다층 철골 모멘트 저항 골조의 동적응답을 해석적으로 규명하였다. 본 연구의 목적은 구조해석을 수행하여 최대 층간변위 및 최대응력법에 의해 효율적인 점탄성 감쇠기의 위치를 결정하는 것이다. 또한, 효율적인 진동 제어방법을 모색하기 위하여 점탄성 감쇠기 및 납삽입고무베어링형 면진장치에 의한 제어효과를 부재력, 조합응력, 그리고 구조물의 고유주기 등을 이용하여 상호 비교 분석하였다.

비좌굴가새의 보강 전과 후의 철골 특수모멘트저항골조 건물의 R계수 평가 (Evaluation of Response Modification Factor of Steel Special Resisting Frame Building Before and After Retrofitted with Buckling Restrained Brace)

  • 신지욱;이기학;조영욱
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.11-19
    • /
    • 2013
  • This research presents that seismic performance of steel moment resisting frame building designed by past provision(UBC, Uniform Building Code) before and after retrofitted with BRB (Buckling-Restrained Brace) was evaluated using response modification factor (R-factor). In addition, the seismic performance of the retrofitted past building was compared with that specified in current provision. The past building considered two different connections: bilinear connection, which was used by structural engineer for building design, and brittle connection observed in past earthquakes. The nonlinear pushover analysis and time history analysis were performed for the analytical models considered in this study. The R-factor was calculated based on the analytical results. When comparing the R-factor of the current provision with the calculated R-factor, the results were different due to the hysteresis characteristics of the connection types. After retrofitted with BRBs, the past buildings with the bilinear connection were satisfied with the seismic performance of the current provision. However, the past buildings with the brittle connection was significantly different with the R-factor of the current provision.

내진 보강된 철골모멘트골조의 취약성 등고선을 통한 성능평가 (Performance Evaluation of Steel Moment Resisting Frames with Seismic Retrofit Using Fragility Contour Method)

  • 김수동;이기학;정성훈;김도현
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.33-41
    • /
    • 2013
  • Due to a high level of system ductility, steel moment resisting frames have been widely used for lateral force resisting structural systems in high seismic zones. Earthquake field investigations after Northridge earthquake in 1994 and Kobe earthquake in 1995 have reported that many steel moment resisting frames designed before 1990's had suffered significant damages and structural collapse. In this research, seismic performance assessment of steel moment resisting frames designed in accordance with the previous seismic provisions before 1990's was performed. Buckling-restrained braces and shear walls are considered for seismic retrofit of the reference buildings. Increasing stiffness and strength of the buildings using buckling-restrained braces and shear walls are considered as options to rehabilitate the damaged buildings. Probabilistic seismic performance assessment using fragility analysis results is used for the criteria for determining an appropriate seismic retrofit strategy. The fragility contour method can be used to provide an intial guideline to structural engineers when various structural retrofit options for the damaged buildings are available.