• Title/Summary/Keyword: 모루

Search Result 13, Processing Time 0.024 seconds

Rod Energy Ratio Measurement of SPT (표준관입시험의 동적효율 측정)

  • Lee, Ho-Chun;Kim, Byeong-Il;Park, Yong-Won
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.169-182
    • /
    • 1997
  • It is known that some amount of loss in impact energy takes place due to some limitations and problems during the performance of the field SPT. Actual energy level tractsferred to the rod should be measured to correct the SPT-N values tested in the field In this paper, the ratio of energy transferred to the rod through the anvil to impact energy is measured by using sharpy impact test equipment and also analysed by using GRL-WEAP This result is certified and compared with that of field SPT As the results of this study, the average rod energy ratio of the R-P hammer and the Trip hammer is calculated at 0.726 and 0.728 respectively, but it is suggested that 0.72 should be used. By using the hammer energy ratio 64.2% and 75.0% obtained from field measurement, the average energy ratio of the SPT for the R-P hammer is calculated at 46.7% and 54.5% for the Trip hammer.

  • PDF

On the Relation Between Cloud-to-Ground Lightning and Rainfall During 2006 and 2007 Summer Cases (2006-2007년 여름 사례로 본 구름-지면 낙뢰와 강우의 관계)

  • Oh, Seok-Geun;Suh, Myoung-Seok;Lee, Yun-Jeong
    • Journal of the Korean earth science society
    • /
    • v.31 no.7
    • /
    • pp.749-761
    • /
    • 2010
  • A relationship between cloud-to-ground lightning and rainfall was investigated by using the two-years (2006-2007) summer lightning data and the automatic weather stations (AWSs) data of the Korea Meteorological Administration. The negative lightning occurred at the core of highly concentrated convection, which is often accompanied with heavy rains. Whereas most positive lightning occurred at the anvil cloud with low density and light rains. The rainfall intensity is strongest when the negative and positive lightning occurred concurrently, and one with lightning is much stronger than that without lightning. A portion of the positive lightning of the total lightning was less than 10% during summer seasons, and the lightning without rains was about 34%. The rain rate was strongly correlated with the negative flash rate, and the correlation coefficients varied between 0.87 and 0.94 according to the co-location radius (5-15 km) of AWSs. Most of the lightning occurred 10 minutes before and/or concurrently occurred with rains. A portion of the convective rainfalls of the total rainfalls was at least 20% when we define the rainfalls with lightning as convective. The convective rainfall was greater during August than in June and July. In general, the portion of convective rainfalls showed a maximum diurnal variation during late afternoon as in the rains and lightning.

Characteristics of Brightness Temperature of Geostationary Satellite on Lightning Events during Summer over South Korea (여름철 낙뢰 발생 시 정지궤도 위성의 휘도온도 특성)

  • Lee, Yun-Jeong;Suh, Myoung-Seok;Eom, Hyo-Sik;Seo, Eun-Kyoung
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.744-758
    • /
    • 2009
  • The characteristics of brightness temperature (BT) of infrared and water vapor channels from MTSAT-1R have been investigated using 12 persistent and frequent lightning cases selected from the summer lightnings of 2006-2008. The infrared (IR1, 10.3-11.3 ${\mu}M$) and water vapor (WV, 6.5-7.0 ${\mu}M$) channels from the MTSAT-1R and the lightning observation data from Korea Meteorological Administration are used. When there is no lightning, the BTs of the IR1 and WV channels show the largest frequency at around 290-295K and 245K, respectively. On the other hand, the BTs of two channels show the largest frequency at 215K caused by strong convection when there is lightning. As a result, the WV-IR1 difference (BTDWI) sharply increases from -50K to 0K. Although it depends on the evolution stage of thunderstorms, the lightning mainly occurs at the core of circular convection in the mesoscale convective complex (MCC), whereas the lightning occurs by concentrated line-shape in the squall line. A strong positive correlation exists between the lightning frequency and the BT in the MCC regardless of the BT, but only at the very cold BT in the squall line. In general, the characteristics of BT are well defined for the lightning occurring in the concentrated line, but they are not well defined in the MCC, especially during the decaying stage of MCC. When they are defined well, the lightning occurs when the BTs of IR1 and WV are lower than 215K, BTDWI is near -3 to 1K, and local standard deviation of IR1 decreases to around 1K.