• Title/Summary/Keyword: 모니터링 계측시스템

Search Result 444, Processing Time 0.033 seconds

Measuring Deformation of Cable in the Tensegrity Structure by Optical FBG Sensor (FBG센서를 이용한 텐서그리티 구조의 변형 계측)

  • Lee, Seung-Jae;Lee, Chang-Woo;Ju, Gi-Su
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.189-194
    • /
    • 2008
  • The main object of this paper is that it's possible to monitoring the deformation of cable in the tensegrity structure. always monitoring system of Fiber Bragg Grating(FBG)Sensor is described. The measurement of parts on the cable is very important. We make an experiment with measuring deformation of cable in the tensegrity structure to the pressure conditions. In the result of experiment, the fiber sensors showed good response to the pressure conditions. Therefore, We could calculate the deformation of cable structure and be possible health monitoring of the tensegrity structure.

  • PDF

Monitoring non-point source pollution loadings in irrigated rice paddy fields (저수지 관개논 비점오염부하 모니터링 기법 연구)

  • Kang, Moon-Seong;Song, In-Hong;Choi, Jin-Yong;Lee, Kyong-Do;Jang, Jeong-Ryeol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.475-475
    • /
    • 2011
  • 우리나라 토지계 비점오염부하에서 농촌계 발생오염부하 비중은 질소와 인이 가각 74%와 55%로 보고되고 있다. 이러한 농촌계 오염부하에서 저수지 관개논에서의 오염부하 비중은 질소와 인이 각각 29%와 44%이며, 전체 논 대비 저수지 관개논 비중은 45%에 달하고 있다. 따라서 하천 및 호소의 수질향상을 위해서는 저수지 관개논의 비점오염배출에 대한 효과적/체계적인 관리가 필요하다. 본 연구의 목적은 저수지 관개논에서의 비점오염부하를 정량화하기 위하여, 저수지 관개논 비점오염부하 모니터링 기법 정립 및 계측시스템을 구축하고, 비점오염부하의 종합적인 모니터링을 통하여 비점오염원 주요 관리인자의 상호관련성을 정량적으로 분석/평가하는 데 있다. 대상지구는 이동저수지 하류에 위치한 관개논을 선정하고, 수문수질 계측망을 구성하였다. 강수량, 증발산량, 담수심, 침투수량, 관개수량, 배수량 등의 수문/수질인자와 토양 인자 및 작물생육특성 등에 대한 모니터링을 통하여 관개논에서의 비점오염부하를 정량적으로 산정하였다. 이를 바탕으로 각각의 비점오염부하에 영향을 미치는 주요 인자 상호 관련성을 정량적으로 평가하였다. 본 연구는 현재 초기 연구에 해당되며 향후 지속적인 모니터링 및 정량적 평가가 이루어져야 하며, 농업비점오염에 의한 수체에 미치는 영향을 분석함으로서 지속가능한 농업, 수계의 수질보전대책 수립, 그리고 물환경 정책 도출 및 수립에 활용이 가능할 것으로 기대된다.

  • PDF

Structural Health Monitoring System for Large-Bridge-Based LoRa LPWAN (LoRa LPWAN 기반의 대형 교량 구조건전성 모니터링 시스템)

  • Jin-Oh Park;Ki-Don Kim;Kyung-soo Kim;Sang-Heon Park
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.1
    • /
    • pp.49-56
    • /
    • 2023
  • With the development of technology worldwide, bridges are becoming larger, and the number of old bridges is also rapidly increasing. Monitoring the structural health of large, aging bridges is essential to preventing large-scale accidents. In this study, the application of a LoRa low-power wide-area network (LPWAN)-based wireless measurement system was investigated, and a LoRa wireless measurement system was established in the cable-stayed bridge section of Cheonsa Bridge, located in Shinan-gun, Jeollanam-do, Korea. The applicability of the LoRa LPWAN-based wireless monitoring system to large marine bridges was reviewed by comparing the performance and economic feasibility with wire-based monitoring systems that were built and operated by establishing a measurement system for the pylons, cables, and reinforcing girders of the bridge.

Monitoring System Construction of Bricks Manufacture Process Using RFID (RFID를 이용한 벽돌제조 공정 모니터링 시스템 설계)

  • Kim, Gui-Jug
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.447-450
    • /
    • 2006
  • 본 연구는 국내에서 발생되는 소각재를 재활용하여 벽돌 생산을 하는 공장에서의 이원화된 작업현황을 일원화 할 수 있는 데이터 모니터링 시스템 구축을 목적으로 한다. 이를 위하여 RFID 센싱 기술을 생산 공정에 도입하여 공정관리 시스템을 획기적으로 개선할 수 있도록 하였다. 각종 계측기 및 센서의 신호를 데이터 수집 장치인 IDMC-Net8842를 이용하여 실시간으로 수집하고 유/무선 통신 모듈을 이용한 TCP/IP 연결을 통하여 모니터링 서버에 접속하여 실시간으로 현장의 상황을 확인하여 제어할 수 있는 시스템을 구축하고자 한다.

  • PDF

Application of Resistivity/SP Monitoring Technique to Maintenance of Water Utilization Facilities (수리시설물의 유지관리를 위한 비저항/SP 모니터링기법 연구)

  • Park, Sam-Gyu;Kim, Jung-Ho;Seo, Goo-Won;Won, Jong-Geun;Kim, Byung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.71-76
    • /
    • 2005
  • The subject of this paper is research into the application of resistivity/SP monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity/SP measurement, inclinometer, piezometer, and water gauge at an embankment, Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and SP variations that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variations of resistivity and SP at the embankment were provided from the monitoring data and we could accurately locate the portions of which resistivities and SP have sharply changed, Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity and SP, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity and SP data would be much more preferable to performing the just one-time measurements.

  • PDF

Application of Electrical Resistivity Monitoring Technique to Maintenance of Embankments (저수지의 유지관리를 위한 전기비저항모니터링 기법 응용)

  • Park Sam Gyu;Kim Jung-Ho;Seo Goo Won
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The subject of this paper is research into the application of electrical resistivity monitoring to detecting the water leakage of water utilization facilities. For this purpose, we installed a comprehensive monitoring system consisting of resistivity measurement, inclinometer, piezometer, and water gauge at an embankment. Using this monitoring system, we monitored the various kinds of measurement data and compared the resistivity structures and that of hydrological and engineering data in order to investigate the water leakage and stability of the embankment. The variant images of electrical resistivity at the embankment were provided from the monitoring data and we could accurately locate the portion of which resistivities have sharply changed. Furthermore, we could estimate the stability of the embankment more effectively and quantitatively by jointly interpreting the monitoring data of resistivity, water level, pore water pressure, and subsurface displacement. The monitoring experiments in this study led us to the conclusion that for the efficient maintenance of the water utilization facilities, monitoring the resistivity data and hydrological data would be much more preferable to performing the just one-time measurements.

The Real-time Health Monitoring System of a Cable-stayed Bridge Based on Non-destruction Measurement (비파괴계측에 의한 사장교의 공용간 상시안전감시시스템)

  • Choi, Man-Yong;Kang, Kyung-Koo;Kim, Jong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.239-245
    • /
    • 2002
  • Many civil and infrastructures continue to be used despite aging and the associated potential for damage accumulation. Therefore, the ability to monitor the health of these systems is becoming increasingly important. The purpose of this paper is to propose a real-time health monitoring system of cable-stayed bridge, based-on non-destructive measurement. And also this paper focuses on the safety assessment for bridge from health monitoring system to accomplish this safety assesment. Using the proposed health monitoring system, it helps bridge maintenance and reduces the economic cost of a life-cycle costs. Also it give important data to develop the design and analysis method for cable-stayed bridges.

Implementation of the Portable ECG System Using Moving Average Filter and Adaptive Signal Processing (이동평균필터와 적응신호처리를 이용한 휴대형 ECG 시스템 구현)

  • Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.989-993
    • /
    • 2008
  • 본 연구에서는 생체신호 중 비침습적으로 측정이 가능하고 많은 건강정보를 포함하고 있는 ECG(electrocardiogram)신호를 일상생활 중 보다 편리하게 모니터링 할 수 있는 시스템을 구현하고자 하였다. 이를 위하여 벨트형 ECG전극 시스템을 개발하였으며, 배터리로 구동 가능한 초소형 저전력 ECG측정시스템을 구현하였다. 또한 측정된 ECG신호의 무선전송을 위하여 Zigbee호환 무선센서노드를 이용하여 초저전력 무선데이터 통신부를 구성하였고 PC상에서 ECG신호를 모니터링하기 위한 프로그램을 구현하였다. 그리고 ECG측정 시 움직임에 따라 발생하는 동잡음의 제거를 위하여 이동평균필터(moving average filter)를 이용하여 기저선 변화를 추출하였고 이를 적응필터의 참조신호로 사용하여 동잡음을 제거하였다. 실험 결과 본 연구에 의해 구현된 ECG전극 및 계측시스템을 통해 활동상태 에서도 ECG계측 가능성을 확인하였으며, 제안한 적응신호처리기법을 통해 활동 중 ECG측정에서 동잡음의 최소화가 가능함을 확인하였다.

  • PDF

User-centric Scalability Measurement System of Large-Scale Measurement Data for 400km/h High-Speed Railway (400km/h 고속철도 대규모 계측데이터 사용자 중심 확장성 계측시스템)

  • Hwang, Kyung-Hun;Park, Sun-Kyu;Song, Byung-Keun;Yang, OK-Yul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1157-1163
    • /
    • 2014
  • Needs for a new technologies of infrastructure systems arose, following the development of next generation EMU(Electric Multiple Unit) train with maximum speed over 400km/h. For high-speed operation tests of the new EMU, a high-speed railway infrastructure test-bed was constructed in a 28km long section of the Honam High-speed Railway. Diverse sensors and monitoring system was installed for continuous monitoring of the railway. Due to such effort, further demands and needs of the integrated monitoring system was derived in a more comprehensive and long-term perspective.