• Title/Summary/Keyword: 면진건물

Search Result 46, Processing Time 0.024 seconds

Performance Evaluation of Vibration Control of High-rise Buildings Connected by Sky-Bridge (스카이브릿지로 연결된 고층건물의 진동제어 성능평가)

  • Kim, Hyun-Su;Yang, Ah-Ram;Lee, Dong-Guen;Ahn, Sang-Kyung;Oh, Jung-Keun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.4
    • /
    • pp.91-100
    • /
    • 2008
  • In this study, the vibration control performance of high-rise building structures connected by a sky-bridge has been investigated. The philosophy of vibration control using sky-bridges is to allow structures with different dynamic characteristics to exert control forces upon one another through sky-bridges to reduce the overall responses of the system. The the high-rise building structure connected by sky-bridge with 49 and 42 stories was used in this study to investigate the displacement, acceleration, reaction of bearings and stress of sky-bridge by analytical methods. To this end, historical earthquakes, an artificial earthquake and wind force time histories obtained from wind tunnel tests were used. Based on the analytial results, the use of sky-bridge can be effective in reducing the structural responses of high-rise buildings against wind and seismic loads.

  • PDF

Application of Seismic Isolation Technique in Residential-Commercial Building (주상복합건물에 대한 면진기술의 적용)

  • 이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.465-472
    • /
    • 2000
  • Seismic isolation technique has been applied mainly in low rise buildings and its seismic performance was satisfactory during Kobe Earthquake. However, in the case of medium and/or high-rise buildings, mid-story isolation could be more technically feasible than base isolation to reduce earthquake forces. In this paper, the seismic effectiveness of mid-story isolation in medium and/or high-rise shear building as well as low rise shear building was evaluated analytically. After verifying the effectiveness of mid-story isolation technique, this method also applied in residential-commercial building. It was found that mid-story isolation, that is isolation between upper residential area and lower commercial area, could reduce inter-story drift and floor shear forces comparing to the conventional fixed base.

  • PDF

Characteristics of Earthquake Responses of an Isolated Containment Building in Nuclear Power Plants According to Natural Frequency of Soil (지반의 고유진동수에 따른 면진 원전 격납건물의 지진응답 특성)

  • Lee, Jin Ho;Kim, Jae Kwan;Hong, Kee Jeung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.245-255
    • /
    • 2013
  • According to natural frequency of soil, characteristics of earthquake responses of an isolated containment building in nuclear power plants are examined. For this, earthquake response analysis of seismically isolated containment buildings in nuclear power plants is carried out by strictly considering soil-structure interactions. The structure and near-field soil are modeled by the finite element method while far-field soil by consistent transmitting boundary. The equation of motion of a soil-structure interaction system under incident seismic wave is derived. The derived equations of motion are solved to carry out earthquake analysis of a seismically isolated soil-structure system. Generally, the results of this analysis show that seismic isolation significantly reduces the responses of the soil-structure system. However, if the natural frequency of the soil is similar to that of the soil-structure system, the responses of the containment buildings in nuclear power plants rather increases due to interactions in the system.

An Experimental Study on the Dynamic Behavior of the Seismic Isolator for Telecommunication Equipment Installed in a 15-Story Reinforced Concrete Building (15층 철근콘크리트 건물에 설치된 통신설비 면진장치 동적 거동에 대한 실험적 연구)

  • Choi, Hyoung Suk;Jung, Donghyuk;Seo, Young Deuk;Baek, Eun Rim
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.241-249
    • /
    • 2021
  • Communication facilities play an essential role in disaster situations. Therefore, communication facilities need to have structural and functional safety during and after earthquakes. Recently, technology for partial seismic isolation has been increasing to protect data facilities and communication equipment installed in buildings from earthquakes. However, excessive displacement may occur in the seismic isolator during an earthquake due to the resonance between the building and the seismic isolator having long-period characteristics, which may cause overturning and separation of the installed equipment. In this study, analytical and experimental studies were conducted to evaluate the safety of seismic isolators installed in high-rise buildings. It was confirmed that damages might occur in buildings' seismic isolator, with resonance characteristics of less than 1 Hz.

Seismic Response Evaluation of High-Rise Buildings Considering Installation Story of the Mid-Story Isolation System (중간층 면진시스템 설치 위치에 따른 고층건물의 지진응답 분석)

  • Kim, Ka-Yeong;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.85-92
    • /
    • 2017
  • Base isolation system is generally used for low-rise buildings. For high-rise buildings subjected to earthquake loads, a mid-story isolation system was proposed and applied to practical engineering. In this study, seismic responses of high-rise buildings considering the installation story of the mid-story isolation system were evaluated. To do this, the 20-story and 30-story building were used as example structures. Historical earthquakes such as Kobe (1995), Northridge (1994) and Loma Prieta (1989) earthquakes were employed applied as earthquake excitations. The installation location of the mid-story isolation system was changed from the bottom of the $1^{st}$ floor to the bottom of the top floor. The seismic responses of the example building were investigated by changing the location of the isolation layer. Based on the analytical results, when the seismic isolation system is applied, story drift ratio and acceleration response are reduced compared to the case without the isolation system. When the isolation layer is located on the lower part of the building, it is most effective. However, in that case, the possibility that the structure is unstable increases. Therefore, an engineer should consider both structural efficiency and safety when a mid-story isolation system for a high-rise building is designed.

Analysis of Seismic Response According to Installation Location of Seismic Isolation System Applied to High-Rise Building (고층 건물에 적용한 면진 시스템의 설치 위치에 따른 지진 응답 분석)

  • Kim, Min-Ju;Kim, Dong-Uk;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.81-88
    • /
    • 2018
  • Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.