Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors (Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증)

  • Oh, Se An;Yea, Ji Woon;Lee, Rena;Park, Heon Bo;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.218-224
    • /
    • 2014
  • The small field dosimetry is very important in modern radiotherapy because it has been frequently used to treat the tumor with high dose hypo-fractionated radiotherapy or high dose single fraction stereotactic radiosurgery (SRS) with small size target. But, the dosimetry of a small field (< $3{\times}3cm^2$) has been great challenges in radiotherapy. Small field dosimetry is difficult because of (a) a lack of lateral electronic equilibrium, (b) steep dose gradients, and (c) partial blocking of the source. The objectives of this study were to measure and verify with the various detectors the output factors in a small field (<3 cm) for the 6 MV photon beams. Output factors were measured using the CC13, CC01, EDGE detector, thermoluminescence dosimeters (TLDs), and Gafchromic EBT2 films at the sizes of field such as $0.5{\times}0.5$, $1{\times}1$, $2{\times}2$, $3{\times}3$, $5{\times}5$, and $10{\times}10cm^2$. The differences in the output factors with the various detectors increased with decreasing field size. Our study demonstrates that the dosimetry for a small photon beam (< $3{\times}3cm^2$) should use CC01 or EDGE detectors with a small active volume. And also, Output factors with the EDGE detectors in a small field (< $3{\times}3cm^2$) coincided well with the Gafchromic EBT2 films.

Buddhist Sculpture of Late Silla and Early Goryeo Period at Myeongju and the Gulsan School of Seon Buddhism (명주지역 나말여초 불교조각과 굴산선문)

  • Choe, Songeun
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.2
    • /
    • pp.54-71
    • /
    • 2012
  • This paper investigates Buddhist sculptures of the Gulsan-sa School of Seon Buddhism, which was established by the priest Beomil(梵日) at Myeongju(溟州), present-day Gangneung(江陵) area, and prospered until the late Goryeo period. There are very few surviving Buddhist images at Gulsan2 temple-site showing the Buddhist art when Beomil or his disciples, Gaecheong(開淸) and Haengjeok(行寂), were active, except a set of huge stone pillars for temple-banners and a stone monk stupa. It is therefore necessary to focus on pieces of artworks in Gangneung and nearby areas to explore the characteristics of Buddhist art of Gulsan-sa from the late Silla to early Goryeo period. For example, the stone relief seated Buddha image, one of Four Buddhas of Four Directions, and a stone relief of standing Guardian King both from the stone pagoda at Mujin temple-site(無盡寺址) can be compared with stupa reliefs at the capital Gyeongju area in their high quality of carving. The stone octagonal base showing seven lions on each of seven sides at Boheon-sa(普賢寺) demonstrates that it was made as a part of an octagonal lotus pedestal for a Vairocana Buddha now lost. Since Boheon-sa was erected by Gaechung, a disciple of Beomil as a branch of Gulsan-sa, it is fair to assume that the Vairocana image at Boheon-sa might have been closely related to the Buddhist images at Gulsan-sa in its style and iconography. The stone seated Bodhisattva from Hansong temple-site(寒松寺址) displays a benign face, exquisite necklace, and exotic iconography in its hand gesture and high cylindrical crown. The stone seated Buddha at Cheonghak-sa(靑鶴寺), brought from a temple-site where fragments of roof-tiles with the inscription of Heukam-sa(黑岩寺) were discovered, displays the late Silla and early Goryeo period. Heukam-sa seems to have been related to Gulsan-sa or have been one of the branches of Gulsan-sa. Extant fragments of artworks at Myeongju implicate the high quality of Buddhist art of Gulsan-sa in its iconography and style as well as unique features of Gulsan-sa Seon School.

Effects of $^{60}Co-gamma$ Radiation on Ricebran Oil (미강유에 대한 코발트 60-감마선의 영향에 관한 연구)

  • Han, Deok-Bong;Suck, Han-Gyun;Yoo, Young-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.129-135
    • /
    • 1973
  • The accumulation of peroxides, acid values, and carbonyl values during irradiation and post-irradiation storage of the ricebran oil has been studied. The rice bran oils were irradiated two doses of 2 and 7 megarads (300 rads/sec) at $23^{\circ}C$ atmospheric circumstance. The acid values, peroxide values and carbonyl values were measured at regular intervals of one week during the storage at $5^{\circ}C$ and $25^{\circ}C$. 1) During the storage, the acid values of the irradiated rice bran oils increased or decreased insignificantly regardless of the addition of antioxidants and storage temperature. 2) The peroxide values were not increased continuously but increased zigzag. The result was indicated that the composition and decomposition of peroxides occurred continuously throughout the storage. 3) As the peroxide values increased, carbonyl values decreased and changed quite differently, but, especially in 7th week, they were constant or insignificant. 4) Dibutylhydroxytoluene is more effective than caffeic acid in retarding the formation of peroxides during irradiation of rice bran oils and post-irradiation storage. The effect of antioxidant is more efficient at 2 megarads than at 7 megarads irradiation. When we store the rice bran oil, the addition of antioxidants of post-irradiation is more desirable than that of preirradiation. 5) In spite of changing conditions such as storage temperature and addition of antioxidants, the peroxide values of rice bran oils irradiated at 2 megarads were always greater than those at 7 megarads during the storage. Peroxide values of samples at high temperature $(25^{\circ}C)$ storage increased as twice as those of low temperature $(5^{\circ}C)$ storage samples. At low temperature, peroxide values in the first week increased twice during the period of 8th weeks storage, but those did from three to four times at higher temperature in the same period Therefore, the low temperature storage is recommandable too.

  • PDF

A Study on the Neutron in Radiation Treatment System and Related Facility (방사선치료 장치 및 관련시설에서의 산란 중성자에 관한 연구)

  • Kim Dae-Sup;Kim Jeong-Man;Lee Hee-Seok;Lim Ra-Seung;Kim You-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • Purpose : It is known that the neutron is generally generated from the photon, its energy is larger than 10 MV. The neutron is leaked in the container inspection system installed at the customs though its energy is below 9 MV. It is needed that the spacial effect of the neutrons released from radiation treatment machine, linac, installed in the medical canter. Materials and Methods : The medical linear accelerator(Clinac 1800, varian, USA) was used in the experiment. Measuring neutron was used bubble detector(Bubble detector, BDPND type, BTI, Canada) which was created bubble by neutron. The bubble detector is located on the medical linear accelerator outskirt in three different distance, 30, 50, 120 cm and upper, lower four point from the iso-center. In addition, for effect on protect material we have measured eight points which are 50 cm distance from iso-center. The SAD(source-axis-distance), distance from photon source to iso-center, is adjusted to 100 cm and the field size is adjusted to $15{\times}15cm^2$. Irradiate 20 MU and calculate the dose rate in mrem/MU by measuring the number of bubble. Results : The neutron is more detected at 5 position in 30, 50 cm, 7 position in 120 cm and with wedge, and 2 position without mount. Conclusion : Though detection position is laid in the same distance in neutron measurement, the different value is shown in measuring results. Also, neutron dose is affected by the additional structure, the different value is obtained in each measurement positions. So, it is needed to measure and evaluate the neutron dose in the whole space considering the effect of the distance, angular distribution and additional structure.

  • PDF

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

The Pattern of Pusan Station Shopping District( I ) (부산역(釜山驛) 상점가(商店街)의 패턴( I ))

  • Kim, Won-Kyung
    • Journal of the Korean association of regional geographers
    • /
    • v.5 no.1
    • /
    • pp.25-75
    • /
    • 1999
  • This study concern with the pattern of Pusan Station Shopping District within Pusan City, Korea, one of the third ranked centers within Pusan-the first ranked is CBD, the second is subCBD, the third are Spa Shopping district, Tongnae shopping district, Jobang-Ap shopping district and Yangjeong shopping district. This paper serves as a part of series studies which attempt to clarify the internal structure of Pusan as a whole. Part(I) of this study deals with the pattern of functions including information & culture, business, recreation and retailing. The results are as follows. 1. Pusan Station is one of higher ranked class of central places within Pusan City. But the ratio of dwelling houses is the highest in Pusan Station among the 9 higher ranked central places within Pusan. It means that the residential areas still remain along the maze type of narrower streets inner part of the blocks, especially western belt of this shopping district. 2. Business functions are one of the important criteria which classified the central places within the city and Pusan Station is the first ranked shopping districts in terms of these criteria among the 9 higher ranked central places including CBD within Pusan City. It suggests that Pusan Station is the miniature of the CBD, SubCBD is not the miniature of CBD in the view point of business function. It also means that Pusan Station Shopping District has been developed as a special shopping district or as a special central place. It has not been evolved as a center of the hierarchy of central places within the city by the natural or organic growth. 3. Pusan Station as 'the third space or drinking place' and it's characteristics as a amusement center presents at so called the 'Texas Town'-free tax area- whose customers are mainly U. S. soldiers and foreign sailors. But from the 1990s, this 'Town' changed to 'Russian Town', You can easy to meet many Russians and Russian lettered signboards-not English- along the street. 4. Convenient stores distribute mainly at back streets or along the narrower streets. It means that this kinds of stores have a residential oriented character. And a certain convenient stores locate with almost same distances. It suggests that it's hinterland is limited in nearer neighborhoods.

  • PDF

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF