• Title/Summary/Keyword: 면거즈

Search Result 7, Processing Time 0.02 seconds

The Comparison of Methods Processing Cells Recovered by Bronchoalveloar Lavage (기관지폐포세척액에서 세포수 측정을 위한 처리방법의 비교)

  • Park, Jae-Seuk;Kim, Jae-Yeal;Lee, Gwi-Lae;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Young-Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.176-183
    • /
    • 1998
  • Background: The total and differential cell count of bronchoalveolar lavage(BAL) fluid are useful assessing activity, prognosis and response to therapy in diffuse interstitial lung disease. But controversy exist as to the appropriate method in processing BAL fluid. Therefore we investigated the effect of gauze filtration, centrifugation and different storage time of BAL fluid on the total and differential cell count. Methods: We obtained BAL fluid from 6 persons with no active lung lesion and divided pooled BAL fluid into several siliconized glass tubes and filtered through 0, 1, 2, 4 folds of cotton guaze(pore size: 1mm), and compared total cell count using hemocytometer after trypan blue staining and differential cell count after Wright-Giemsa staining of cytocentrifuged preparations. And we also counted total and differential cell count after centrifugation(400g for 30 min) and various storage time(2hr, 24hr, and 48hr). Results: There was no difference in total and differential cell count according to folds of gauze filtraion. But without gauze filtration, mucus threads that hampered total and differential cell count were found in 2 cases (33%). Centrifugation resulted in loss of total cell count($24{\pm}18%$) without change in differential cell count. There was no change in total cell count after 2hr storage but significant cell loss was found after 24hr storage time(24hr : $28{\pm}21%$, 48hr : $41{\pm}24%$). However there was no change in differential cell count with 48hr storage time. Conclusion: Total and differential cell count of BAL fluid may be best performed after cotton gauze filtration without centrifugation and within 2 hours.

  • PDF

Study on Fashion Design Applying Felt (펠트(Felt)를 이용한 의상 디자인 연구)

  • Oh Yean-Ok
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.8 no.1
    • /
    • pp.59-67
    • /
    • 2006
  • In textile industry of $21^{st}$ century, to develop materials and designs in fashion industry is being recognized widely as an urgent problem. In other words, the reality is that we must offer scarcity value and unique materials, and make a positive effort in a time when consumers' individuality appeals and an interest in fashion becomes higher. Felt is not only the oldest material in human history, but also a technique, and its applications are being handed down broadly. I have made various materials based mainly on a traditional felt technique using merino wool and nuno felt technique felting merino wool to cotton gauze. In nuno felt thing, I could observe that as wool and cotton was created as a single composite material, each material's aesthetic, sensuous, functional and emotional description became much more diversified. The purpose of this study is to produce fashion materials using materials with rich texture to meet the consumers' preference and diversity which are increasingly individualized, to design them and to seek possibility of developing differentiated wool materials which can satisfy the consumers' individuality demand and preference.

  • PDF

EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS (상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향)

  • Yoon, Sung-Young;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.113-119
    • /
    • 2009
  • The purpose of this study was to compare the tensile bond strength of several self-adhesive resin cements bonded to dentin surfaces with different wet conditions. Three self-adhesive resin cements: Rely-X Unicem (3M ESPE, St. Paul, MN. USA). Embrace Wetbond (Pulpdent. Oakland. MA. USA). Maxcem (Kerr. Orange. CA. USA) were used. Extracted sixty human molars were used. Each self-adhesive resin cement was adhered to the dentin specimens (two rectangular sticks from each molar) in different wet conditions. Tensile bond strength were measured using universal testing machine (EZ Test. Shimadzu corporation. Kyoto. Japan) at a crosshead speed of 1.0mm/min. After the testing. bonding failures of specimens were observed by Operative microscope (OPMI pro, Carl Zeiss. Oberkochen, Germany). T-test was used to evaluate the effect of dentin surface wetness. One-way ANOVA test was used to evaluate the tensile bond strength of self-adhesive resin cements in the same condition. Scheffe's test was used for statistical analyzing at the 95% level of confidence. The result showed that wetness of dentin surface didn't affect tensile bond strength of self-adhesive resin cements and Maxcem showed the lowest tensile bond strength.

EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN (수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향)

  • Kim, Hak-Geun;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of increasing application time of single bottle adhesives (SBA) to microtensile bond strength (MTBS) of dried dentin. To expose the superficial dentin surfaces, human molars were sectioned perpendicular to the long axis of tooth. $32\%$ phosphoric acid gels were applied for 15s and rinsed. The teeth were randomly assigned to 3 groups ; S group (Single Bond), O group (One-Step), P group (Prime & Bond NT). Each group was divided to 3 subgroups (W: dentin wipe with wet gauge and light cured immediately, D, dentin dried for 30s and light cured immediately, 30: dentin dried for 30s and light cured after applying SBA for 30s). Composite resin was built up on the dentin surface and sectioned to obtain 20 specimens with $1mm^2$ cross sectional area and the MTBS was measured. For Single Bond, the mean MTBS of S-W and S-30 group were higher than that of S-D group statistically (P<0.05). For One-Step, the mean MTBS of O-D group was statistically lower than that of O-W group (P<0.05). For Prime & Bond NT, the mean MTBS of P-30 group was statistically lower than that of P-D group (P<0.05).

Exposure and Risk Assessment for Operator Exposure to Insecticide Acetamiprid during Water Melon Cultivation in Greenhouse using Whole Body Dosimetry (수박 시설재배에서 살충제 Acetamiprid 사용 시 전신노출법에 의한 농작업자의 노출 및 위해성평가)

  • Kim, Eunhye;Lee, Jiho;Sung, Jeonghee;Lee, Jonghwa;Shin, Yongho;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.247-257
    • /
    • 2014
  • Assessment for operator's dermal and inhalation exposure to acetamiprid during cultivation of water melon in greenhouse was carried out. For dermal exposure measurement, whole body dosimetry (WBD) was performed as the first trial in Korea. WBD consists of cotton/polyester outer clothes and cotton inner clothes. Hand exposure was measured by washing of nitrile gloves and hands while head exposure was monitored by face/neck wipe technique. Inhalation exposure was monitored with personal air sampling pumps and IOM sampler (glass fiber filter). Analytical limit of quantitation was 2.5 ng/mL. Good reproducibility (C.V < 8.7%), linearity ($R^2$ > 0.99) and recovery (70~119%) were obtained. Field recovery of acetamiprid was 77~95%. During mixing/loading, hand exposure of acetamiprid was about 10 times ($229.7{\mu}g$) more than that of application case ($20.9{\mu}g$). During application, total dermal exposure was $1207.4{\mu}g$. Exposure of lower legs was $1132.1{\mu}g$, which is 93.8% of the total dermal exposure. Inhalation exposure during mixing/loading and application was not detected. Margin of safety (MOS) was calculated for risk assessment using male Korean average body weight (70 kg) and acceptable operator exposure level ($124{\mu}g/kg/day$) to give 140, suggesting that health risk of operator during treatment of acetamiprid for water melon in greenhouse could be safe.

THE INFLUENCE OF THE VITAL BLEACHING AGENTS ON TRANSLUCENCY OF THE BOVINE ENAMEL (생활치 미백제가 우치 법랑질의 투명도에 미치는 영향)

  • Kim, Dong-Jun;Kim, Young-Ju;Kim, Hak-Geun;Park, Eun-Jong;Seo, Eun-Ju;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.178-183
    • /
    • 2005
  • This study was done to evaluate whether vital bleaching agents could influence on the translucency of the bovine enamel. The anterior bovine teeth that were extracted one day before and without any gross discoloration were obtained and then were preserved in physiologic saline. 6 mm cylindrical tooth specimens were fabricated with diamond puncher perpendicularly on labial surface of bovine tooth. After embedded in transparent acrylic resin with labial surface being exposed, they were cut to a thickness of 1.2 mm with low speed diamond saw (Isomat, Buehler Co., Lake Bluff, IL, USA). They were smoothly ground to 1 mm thickness of enamel with sandpaper. 24 specimens were randomly divided into 3 groups and control group respectively. Opalescence (10% carbamide peroxide, Ultradent, South Jordan, USA), Rembrandt (10% carbamide peroxide, DenMat, USA) and Opalescence F (15% carbamide peroxide with fluoride, Ultradent, USA) were applied on labial sides of the bovine enamel for 7 days (bleaching agents were reapplied every 24 hours) and the opposite surface was contacted to cotton that soaked in distilled water. The control group was soaked in distilled water. Three stimulus value X, Y and Z were evaluated with colorimeter (Color ' Color Differencerneter, Model TC-6FX, Tokyo Denshoku Co., Japan) on the labial surface of all specimen three times on white and black background plate before the bleaching agents were applied and on 3rd, 5th and 7th day after applied. The degree of translucency was normally assessed by measuring the inverse property, opacity (contrast ratio). 10% Opalescence, 15% Opalescence-F, and control group showed no significant variation in the translucency of bovine enamel, However Rembrandt decreased the translucency of it (p < 0.01).

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF