• Title/Summary/Keyword: 먹는물

Search Result 124, Processing Time 0.03 seconds

International Trends for Radionuclides Management in Drinking water (선진 외국에서의 먹는물 중 방사성물질 관리동향)

  • Park, Sun-Ku;Son, Ji-Hwan
    • Journal of Environmental Policy
    • /
    • v.5 no.2
    • /
    • pp.49-67
    • /
    • 2006
  • The radionuclides in drinking water have been regulated in many countries. In USA, the regulation has been revised for over 30 years since radionuclides have been regulated under Safe Drinking Water Act(SDWA) from 1974. Today, USEPA is finalizing maximum contaminant level goal(MCLG) of zero for radionuclides, maximum contaminant level(MCL) and alternative maximum contaminant level(AMCL) of 300pCi/L and 4,000pCi/L for radon respectively, MCLs of $30{\mu}g/L$ for uranium, and MCLs of 5pCi/L for combined radium 226 and 228. In Canada, Maximum Acceptable Concentration(MAC) value for uranium is $20{\mu}g/L$. WHO revised the guideline value of uranium and radon to $15{\mu}g/L$ and 100Bq/L in september 2004, respectively. On this survey, it has been found that international regulations for radionuclides in drinking water have been established and improved steadily on the knowledge basis from the past decades' studies.

  • PDF

오염방지 시설을 이용한 지하수 환경성 복원 연구

  • 이병대;조병욱;성익환;함세영;정상용;윤성택
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.155-158
    • /
    • 2002
  • 질산성질소 및 탁도로 오염된 지하수공에 대하여 환경성 복원을 위한 오염방지 시설을 시범 설치하였다. 지하수공에 대한 오염 정도를 조사한 결과 PS-1, CW-1, 그리고 CW-2 공이 질산성질소로 오염되어 먹는물 수질기준을 초과하였고, CW-3 공은 탁도가 먹는물 수질기준을 초과하였다. 오염원은 지하수공 개발시 수량 확보를 위하여 그라우팅을 제대로 하지 않은 불량시공으로 인한 오염된 지표수의 유입으로 기인되었다. 금번 연구는 오염된 지하수의 환경성 복원을 위한 것으로, 오염원과 지하수를 격리시켜 오염물질의 지하수 내 유입을 방지할 수 있도록 패커 그라우팅을 완벽하게 다시 실시하였으며, 오염방지시설을 설치하였다. 이 연구를 위하여 먼저 대수층의 분포 및 특성팍악, 지하수공내 지표수의 유입구간 규명, 지하수 오염원, 오염실태, 오염경로 등을 파악하였다 오염방지시설을 설치한 후, 설치 전,후의 질산성질소와 탁도의 함량을 비교하기 위하여 수질 분석을 실시하였다. PS-1의 경우, 오염방지시설 설치전의 질산성질소 함량은 16.1 mg/L 이었으나, 설치후에는 8.1 mg/L, 7.9 mg/L로써 설치전에 비하여 51% 감소되었으며, CW-1은 10.3 mg/L에서 6.3mg/L으로 39%, 그리고 CW-2는 14.9 mg/L에서 9.0 mg/L 으로 40% 감소되었다. CW-3 공의 탁도는 157 NTU에서 0.97 NTU로 완벽하게 복원되었다.

  • PDF

Detection of Enterococci and their Vancomycin Resistance in Drinking Spring-Water (먹는물 약수터 장구균의 검출 특성과 반코마이신 내성 현황)

  • Yoon, Tae-Ho;Lee, Hyang;Lee, Seung-Joo;Yeo, In-Hak;Eom, Seok-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.979-985
    • /
    • 2010
  • This study was performed to detect enterococci strain as an indicator of faecal contamination, to identify of 16S rDNA sequence and vancomycin resistance by MIC (Minimum Inhibitory Concentration) test from drinking spring-water samples in Seoul. The detection frequency of enterococci was 42 (19.8%) among 212 samples, and its concentration was ranged from 0 to 110 CFU/100 mL. These results were confirmed the possibility as an indicator microorganisms that similar to the frequency of E. coli detection (t test p-value 0.268, significant level 0.05). Isolated 56 enterococci samples were identified by 16S rDNA sequence data and their NCBI BLAST searching. They were identified to Enterococcus faecalis of 24 samples, E. faecium (10), E. casseliflavus (10), E. gallinarum (3), E. hirae (2), E. durans (2), E. sanguinicola (1). E. faecalis was dominant species that clinical case report of a domestic was similar. Vancomycin resistant enterococci (VRE) of 53 samples showed that vanB and vanC1/C2 type with 2 and 12 case, respectively. These results indicated that the drinking spring-water quarantined to fecal pollution for block out outbreak of gastrointestinal symptom with using such as disinfection process.