• Title/Summary/Keyword: 매트리스

Search Result 89, Processing Time 0.019 seconds

Dispersing Stress under Geogrid-Mattress Foundation (지오그리드 매트리스기호의 전파듣력에 관한 연구)

  • Ju, Jae-U;Jang, Yong-Chae;Park, Jong-Beom
    • Geotechnical Engineering
    • /
    • v.14 no.4
    • /
    • pp.117-128
    • /
    • 1998
  • Solid mattress foundation using geogrid has often been used on soft grounds to increase the bearing capacity, and its effect has received much recognition. Geogrid-mattress system is the method of construction which increases the bearing capacity and the effect of controlling settlement by dispersing load to wider foundation through its stiffness. But ifs mechanism has not been examined exactly yet. considered to be influential factors in the experiments. As a result of the experiments, the characteristic of dispersing stress under mattress foundations was understood and the way of calculating the bearing capacity in designing the mattress foundations was suggested.

  • PDF

Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table (전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가)

  • Jeon, Sang-Won;Pak, Jae-Yun;Suh, Tae-Suk
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.819-825
    • /
    • 2020
  • The purpose of this study was to evaluate the usefulness of the developed air mattress for reducing the deterioration of image quality due to the scattered radiation generated on the computed tomography equipment table. 5 cm and 10 cm thick air mattresses were developed and the image quality was measured by scanning the AAPM phantom according to thickness and thickness. Statistical significance was confirmed by One Way Analysis of Variance(ANOVA) Compared with the AAPM phantom scanned in the standard method, the image with the air mattress did not show any difference, but when the air mattress was not applied, the CT number and uniformity were low and the noise was high, and the spatial resolution Respectively. The developed air mattress has no harmful effect on the diagnostic image, it is very effective in improving the image quality and can increase the CT image quality by simply applying Air Mattress to existing equipment without using the technology applied to the latest and high-cost equipment.

Study on Critical_Allowable Shear Stress of Filling Rocks With Mattress Revetment (호안용 매트리스내 채움재의 한계_허용 전단응력에 관한 연구)

  • Bae, Sang-Soo;Lee, Seung-Yoon;Jee, Hong-Kee
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Critical and allowable shear stress acting on the mattress revetment, is presented in this study. First of all, shear stress at each spot is computed when the hydraulic power act on the waterway. Secondly, median diameter of the filling rocks is computed using shear stress and Shields coefficient which are used to decide the critical motion of the particle. Finally, the range of critical and allowable shear stress is estimated which meet the particle stability and indicated that the mattress is a stable hydraulic structure in comparison with the riprap. Therefore the required median diameter of riprap is three times higher than that of mattress. Contrarily, this study also analyzed that resisting power of mattress to shear stress is three times higher than that of riprap on the same size.

Analysis of Suitability for Mattresses by Using Psycho-Physiological Measures (심리생리적 지표를 사용한 매트리스 적합도 분석)

  • Yu, Suk-Won;Kim, Jung-Yong;Min, Seung-Nam;Sung, Si-Hoon
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.05a
    • /
    • pp.63-66
    • /
    • 2009
  • 본 연구의 목표는 사용자에게 적합한 매트리스를 선택하는데 도움을 주는 신체적, 심리적 지표를 개발하고, 이를 분석하여 개인의 주관적 만족도와의 상관성을 알아보는 것이다. 시중에 판매되고 있는 5개의 매트리스의 강도를 2개씩 짝지어진 매트리스별 pared t-test를 통하여 강도별 순위를 5등급으로 분류하였다. 10명의 실험 참가자들의 신체적 지표(근전도, 심박수, 산소포화도 측정), 심리적 지표(개인 특성 설문 조사), 체압 및 주관적 만족도 측정을 실시하고, 상관분석을 통해서 이 측정결과와 개인간 주관적 만족도(선호하는 침대의 탄성)와도 일관성이 있는지 조사하였다. 연구 결과, 압력집중도(r=0.818)과 허리근육이완도(r=0.766) 그리고 심박수(r=0.670)가 주관적 만족도와 유의한 상관관계를 가지는 것으로 나타났다.

  • PDF

Comparative Effects of Mattress Type on Subjective and Objective Sleep Quality : A Preliminary Study (매트리스의 종류가 건강한 성인의 주관적, 객관적 수면의 질에 미치는 영향에 대한 탐색적 연구)

  • Choi, Jae-Won;Lee, Yu Jin;Kim, Soohyun;Lee, Joonki;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.2
    • /
    • pp.61-67
    • /
    • 2016
  • Objectives: We aimed to evaluate the effects of mattress type on both objective and subjective sleep quality in healthy good sleepers. Methods: Fifteen healthy good sleepers with a mean age of 30.8 years participated in this study. A randomized crossover trial was carried out using two different mattress types: a standard mattress and a contour coil mattress. After a night of adaptation, all participants were randomized to either a standard mattress or a contour coil mattress. Then, nocturnal polysomnography was conducted for two consecutive nights. Subjective evaluations were obtained using a self-report questionnaire before and after the polysomnographic recording sessions. Results: The polysomnographic showed no differences in total sleep time, sleep stage, or wake time after sleep onset between the two mattress conditions. Of the polysomnographic variables, only sleep onset latency was significantly reduced for the contour coil mattress. Additionally, participants reported better subjective sleep quality when sleeping on the contour coil mattress, according to the questionnaires. Conclusion: The type of mattress might affect not only subjective, but also objective sleep quality, including sleep onset latency.

Effects of Mattress Material Change on Sleep Quality: An Exploratory Study (매트리스 소재변화가 수면의 질에 미치는 영향: 탐색적 연구)

  • Su-Eun Lim;Ki-Hyun Park;Young-Hwa Baek;Si-Woo Lee;Se-Jin Park;Ho-Ryong Yoo;Kwang-Ho Bae
    • Science of Emotion and Sensibility
    • /
    • v.25 no.4
    • /
    • pp.95-106
    • /
    • 2022
  • This study evaluated the effects of latex mattresses on sleep quality and comfort. The participants were 11 healthy adults (five males, six females, mean age 37.7 years, mean height 167.8 cm, and mean weight 67.0 kg) without severe insomnia or other disease that could affect sleep, examined by a clinician. In their personal living space, participants slept on a spring mattress for 7 days, with their sleep registered using a wearable device (Fitbit), a sleep log, the Pittsburgh Sleep Quality Index (PSQI), the Insomnia Severity Index (ISI), and a satisfaction survey. The mattresses were then replaced with latex mattresses, which were used for 14 days. As a result, sleep time increased by 62.9 min on weekdays and 53.2 min on weekends after using the latex mattress, and a significant decrease, of 3.8, as seen on the ISI. As measured by the PSQI, the poor sleepers decreased from 10 to 7, but this was not statistically significant, and in the satisfaction survey, the comfort of the low back, neck, and shoulders was significantly increased. This suggests that changes to latex mattresses may positively affect objective and subjective sleep quality.

Study on the Fire Behavior of Spring Bed Mattress with and Without a Cooling Frame (냉각프레임 설치 유무에 따른 스프링 침대 매트리스의 화재성상에 관한 연구)

  • Seo, Bo-Youl;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.24-29
    • /
    • 2018
  • To improve the fire safety of spring bed mattress, a cooling frame including cooling material (water) was made and a cooling frame was installed under the bed mattress or between the bed mattress and bed mattress base; fire tests (real scale) were conducted with or without a cooling frame. Similar fire behavior was observed at the beginning of the test (approximately 3 minutes). Subsequently, rapid fire growth in the mattress without a cooling frame, but with a cooling frame, the decline progressed without growth. The flame spread on the top surface of the bed mattress was similar in the semicircular direction, and the average flame speed velocity was analyzed at approximately 0.005 m/s. The maximum flame height was found to be approximately 2.7 m without a cooling frame, and approximately 1.8 m with a cooling frame installed. In addition, the maximum heat release rate was measured to be approximately 740 kW without a cooling frame, and approximately 400 kW with a cooling frame installed. As a result, the flame height and heat release rate were reduced when the bed mattress was fired through the installed cooling frame.

A Study on the Hydraulic Characteristics for River Bed Revetments using Mattress (하상보호용 매트리스의 수리학적 특성 연구)

  • Bae, Sang-Su;Heo, Chang-Hwan;Ji, Hong-Gi;Lee, Sun-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.77-90
    • /
    • 2002
  • The condition of initial movement for the river bed revetment using rip rap is a limit condition beyond which the lining is progressively destroyed as the separate elements are removed by the flow. In the case of the river bed revetment using mattress, however, after the initial movement the containment offered by the mesh remains. A new situation of equilibrium with a deformed river bed revetment using mattress is obtained, allowing it to withstand more severe conditions without compromising the resistance and without further bed deformation. Shield's coefficient for the river bed revetment using mattress is twice the value of that for the river bed revetment using rip rap. This means that with the same hydraulic behavior conditions, the average dimension of the rocks to be used in the river bed revetment using mattress is half that of the river bed revetment using rip rap rock. When the same size rocks are used the allowable velocity for the river bed revetment using mattress is more than twice, even as much as 3 or 4 times that for the river bed revetment using rip rap.

Development of Variable Air Mattresses for Shelter based on Disaster Prevention Design (방재디자인기반 구호소 가변식 에어매트 개발)

  • Noh, Hwang-Woo;Chung, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.2
    • /
    • pp.80-87
    • /
    • 2022
  • Most of the disaster relief items provided to sufferers and temporary evacuees that are supposed to be victims in Korea are not suitable for the shelter environment of temporary housing facilities, and are not satisfactory because they do not have the functions, proper size and types. The purpose of this study is to analyze the user needs of emergency rescue relief items by presenting problems about the use environment and to develop the variable air mattresses which are based on disaster prevention design. In order to secure objectivity such as usability, convenience, and durability, research data are limited. However, the difficulty of mass spreading of conventional fiber mat and the functional disadvantages of foam plastic mat are solved by adopting variable air mattresses. The variable air mattresses are expected to help rehabilitate people by helping victims of physical tiredness, illness worsening, poor sleep, and life instability that can happen during long-term shelter life.

Design and Construction of Cellular Foundation Mattress as Foundations of Building Structures (건축구조물 기초로서 셀룰러 기초 매트리스의 설계 및 시공)

  • Jeong Young Lee;Jong Gon Ko;Nguyen Ngoc Son;Jae Hak Park;Doo Kie Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.25-37
    • /
    • 2023
  • Cellular Foundation Mattress made of new materials such as high density polyethylene, are not currently use for the foundation of small and medium-sized buildings in Korea. Therefore, they need to be developed and verified based on domestic ground and field conditions. This study presents the basic design and construction method of Cellular Foundation Mattress. Since the foundation reinforcement effect of Cellular Foundation Mattress should be evaluated and verified for soft ground, a performance comparison evaluation was conducted using the Soilbag method, which is commonly used for the foundation of small and medium-sized buildings in Korea. After the mattress reinforcement, the settlement amount decreased by 38.4% compared to the original ground and the bearing capacity increased by 159%, confirming the same ground reinforcement effect and ground stability as the Soilbag method.