• Title/Summary/Keyword: 매연농도

Search Result 50, Processing Time 0.022 seconds

Practical Study of The Phenomenon and Removal of White Smoke for JBR FGD Plant (JBR FGD Plant에 있어서의 가시매연 발생원인 및 제거 방안 연구)

  • 전상기;조승원;황영호;이병규
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.273-273
    • /
    • 2000
  • 우리나라 대기환경기준은 이미 선진국 수준으로 강화되었거나 강화될 계획으로 있어 이에 따른 대기오염 방지시설의 설치 또는 보완이 요구되고 있다. 특히, 배기가스 중 황산화물 배출농도 강화로 황산화물 저감을 위한 배연탈황설비 설치ㆍ가동중에 있으나 황산 Mist가 주요원인으로 추정되는 Plume Opacity가 발생되어 대기 중에서 색깔을 띄게됨에 따라 오염물질 배출농도는 법적 규제기준 이내로 배출되더라도 인간의 심리적 불안감을 유발할 수 있어, 그 발생원인을 규명함과 동시에 현장여건에 적합한 최적의 황산 Mist 저감방법을 연구하고자 하였다. (중략)

  • PDF

Soot Concentration and Temperature Measurements in Laminar Ethylene Jet Double-concentric Diffusion Flames (동축 이중 에틸렌 확산화염의 매연 농도분포 및 온도 측정)

  • Lee, Gyo-U;Jeong, Jong-Su;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.402-409
    • /
    • 2002
  • Experiments were performed with double-concentric diffusion flame(DDF) in order to investigate the characteristics of soot formation and temperature distributions. The flame size and shape of the DDF are similar to those of the well-known normal co-flow diffusion flame(WF), except the formation of a tiny inverse flame near the central tube exit. A laser light extinction technique was used to measure the soot volume fractions. The temperature distributions in the flame were measured by rapid insertion of a R-type thermocouple. Soot concentrations along the flame axis of the DDF were higher than those of the NDF. However, the maximum soot volume fraction of the DDF along the periphery of the flame was lower than that of the NDF. It is mainly due to the effect of nitrogen-dilution from the inner air. Measured temperature distribution explains these trends of soot concentration. The temperature along the flame axis was also higher in DDF than that of the NDF. However, the flame temperatures at the flame front of the two flames were almost same regardless of the inner flame. This phenomenon means that the inverse flame inside the DDF did not affect on the flame structure including the temperature and soot concentration, except the region around the flame axis.

Some Considerations for Performance of D.I. Diesel Engine Using Auxiliary Fuel Such as Alcohol (알코올을 보조적으로 사용한 직접분사식 디젤기관의 성능에 관한 고찰)

  • 이형곤;방중철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.28-35
    • /
    • 2002
  • The objective of this paper is to quantitatively investigate the effects of alcohol mixture on the combustion improvement of main fuel in supplying alcohol to direct injection diesel engine by auxiliary injection method and blend method. If alcohol is supplied, engine performance greatly improves in high load range. In case of supplying ethanol, BSFC improves, the emission of smoke and NO decreases by delaying main fuel injection timing 5$\^{C}$A. The maximum delivery quantity of alcohol is limited to approximately 50% of total fuel delivery due to misfire and knocking. The limit quantity of main fuel injection that does not accompany misfire and the deterioration of BSFC was approximately 15∼18.5mg/st.

Vegetable oils for diesel fuel substitutes (디젤기관의 대체연료로서의 식물유)

  • 오영택
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.72-92
    • /
    • 1996
  • 식물유, 어유 및 축산 폐기물을 포함한 동식물성 기름은 어느 연료든지 기관의 연료로서 사용 가능하지만, 이들 연료는 점도가 높고, 저휘발성이어서 착화지연기간동안에 가연성혼합기 생성이 어려워 저 NOx이며, 정숙한 운전이 사능할 뿐 아니라 경유정도의 열소비율 및 배기 매연농도로 디젤기관의 대체 연료로서의 충분한 가능성이 있는 연료임을 확인하였다. 그러나, 고점도에 의한 분무 특성의 악화에 기인한 분무입자의 증대로 미연소분에 의한 carbon deposit 및 piston ring stick 등이 문제점으로 지적되었다. 그러나, 이같은 문제점의 해결책으로 경질유와의 혼합, 에스테르 변환 및 연료의 가열등 여러 해결책을 제시하였고, 배기가스분석결과도 양호함을 확인하였다. 이같은 biomass 연료 일종인 식물유가 아무런 변화없이 이용되기 위해서는 고과급화, 단열 및 연소실의 적절한 설계가 필요할 것으로 생각된다. 따라서, 현재의 실황을 생각한다면 기존기관을 특별하게 개조함이 없이 사용을 전제로 할 때 식물유의 이용은 local 에너지로서, 생산, 전환 또는 이용기술의 개발과 동시에 화석에너지의 보충적인 에너지로 고려하는 것이 유효할 것으로 생각된다.

  • PDF

A Study on the Effects of Recirculated Exhaust Gas on Soot Emissions in Diesel Engines (디젤기관 매연 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Bae, M.W.;Lim, J.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.142-154
    • /
    • 1998
  • The effects of recirculated exhaust gas on the characteristic of soot emissions have been investigated by using an eight-cylinder, four-stroke, direct injection and water-cooled diesel engine operating at several loads and speeds. The experiments in this study are carried out at the fixed fuel injection timing of $38^{\circ}$ BTDC regardless of experimental conditions. The intake oxygen concentration and the mean equivalence ratio calculated by the intake air flow and fuel consumption rate are used to analyze and discuss the influences of EGR rate on soot emissions. Results of this study indicate that soot emissions increase owing to the drop of intake oxygen concentration and the rise of equivalence ratio as the EGR rate increases at a given engine load and speed, especially the high load.

  • PDF

Measurements of sooting in single droplet combustion under the normal-gravity condition (정상 중력장하의 단일 액적연소에 있어서 매연 농도의 측정)

  • Lee, Gyeong-Uk;Lee, Chang-Eon;O, Su-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.468-480
    • /
    • 1998
  • The temporal and spatial distributions of soot volume fractions were measured for single toluene droplet flames as a function of pressure under the normal-gravity condition. In order to characterize the transient nature of the flame and sooting regions, a full-field light extinction and subsequent tomographic inversion technique was used. The reduction in sooting as a function of pressure was assessed by comparison of the maximum soot volume fractions at several vertical positions along the axis above the droplet. The maximum soot volume fraction was reduced by 70% when the pressure was reduced by 60% from 1 atm to 0.4 atm. The reduction in sooting is attributed to variation of the geometric configuration of flame which reduces the system Grashof number as well as only the change in the adiabatic flame temperature as the pressure decreases. The gravimetrically-measured total soot yield was also compared to the optically-measured soot volume fraction to obtain a correlation between the two measurements. As a result, the total soot yield was linearly proportional to the optically-measured maximum soot volume fraction and linearly reduced as the pressure decreased. Accordingly, the non-intrusive full-field light extinction-measurements were able to be calibrated not only to measure soot volume fraction, but to simultaneously evaluate the total soot yield emitted from the toluene droplet flame (which is useful in the practical application).

Smoke Characteristics of a Small Scale Pool Eire (작은 풀화재에서의 연기 특성)

  • Lee Eui-Ju;Ahn Chan-Sol;Shin Hyun-Joon;Oh Kwang-Chul;Lee Uen-Do
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.58-63
    • /
    • 2005
  • Experimental measurements of flames and the product properties were performed for small kerosene pool fires. which is widely used as a fire source of laboratory scale experiments with scaling modeling. The flame length and flickering frequency were investigated for the flame structures, and compared with the theory. Three measurement methods were introduced to clarify the smoke characteristics, i.e. various gas concentrations, smoke density and thermophoretic sampling with transmission electron microscopy (TEM). The yield of carbon dioxide and the consumption of oxygen were proportional to the heat release rate of pool fires, but there is no trend on carbon monoxide emission. Smoke density of turbulent flames was exponentially increased with the heat release rate. The morphology of the soot particle was investigated to address the degree of soot maturing. The results show that the similar smoke morphology between an inverse jet flame and a pool fire exists despite of different combustion controlling mechanisms.

Soot Temperature and Concentration Measurement Using Emission/Transmission Tomography in Laminar Diffusion Flame (방사와 투과를 이용한 층류확산화염내 매연입자의 온도 및 농도 측정)

  • 송상종;박성호;김상수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2563-2573
    • /
    • 1993
  • The measurements of monochromatic line-of-sight flame emission and light transmission in the same path having small spatial resolution were performed in an axisymmetric laminar propane $C_{3}H_{8}$ diffusion flame. The light wavelengthes of 632 nm, 800nm, 900nm were used. From these measurements, local point soot radiances (by Kirchhoff's law) and absorption coefficients were reconstructed by tomography. Thus local point soot temperatures and concentrations were obtained. The reconstructed soot temperatures and concentrations of local points have no differences between the case of visible range (632 nm) and the case of infrared range (800 nm and 900 nm). In these ranges, the scattering coefficient is much lower than the absorption coefficient. Soot mean temperature over the path also matches well with local soot temperature in outer region of the flame. Temperature measurement by thermocouple with different bead diameters $(222{\mu}m and 308{\mu}m)$ was carried in the same flame. Rapid insertion technique was used and radiation effect was considered. Radiation correction in the sooting region was carried out and the corrected result was in good agreement with the local soot temperature.

Measurement of soot concentration in flames using laser-induced incandescence method (레이저 가열 측정법을 이용한 화염 내 매연 농도 측정)

  • Jurng, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.75-82
    • /
    • 1996
  • Laser induced incandescence, LII, recently developed technique for measuring soot concentration in flames, can overcome most of limitations of conventional laser extinction measurement. In this study, experiments were performed to investigate the effect of laser intensity, detection wavelength, and also laser beam quality on both LII signal at a particular position and peak-to-centerline LII signal ratio. The results of LII signal with increasing laser intensity shows its near-independence of laser intensity once threshold level of laser intensity has been reached. However, this near-independence depends on laser beam quality and the incident optical setup. The peak-to-centerline LII signal ratio slowly but continuously increases with laser power. This fact is due to the dependence of LII signal on particle mean diameter. LII signal is attenuated during it passes through the flame containing soot particles. The attenuation rate is inversely proportional to detection wavelength. In this study, LII signal at 680 nm band is 10% greater than the signal at 400 nm band.

  • PDF