• 제목/요약/키워드: 말뚝지지력

검색결과 523건 처리시간 0.024초

현장타설 팽이말뚝기초공법의 지지력 증대효과에 관한 모형실험 연구 (Model Test on the Effect of Bearing Capacity for In-situ Top Base Method in sand)

  • 강홍규;김찬국;이봉열;김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.597-602
    • /
    • 2005
  • The present precast top-base method create many problems of requiring it plant facilities, transportation and installation, due to the heavy weight of and it takes too long time to set it up on site. In order to improve and solve these problems, in-situ Top-Base method is developed. It include processes that install Top-Base mold made of poly-ethylene into ground, then pouring concrete into the mold, and fill the rest gaps with broken stones. Considerable advantages can be obtained by applying in-situ Top-Base method in aspects of the stability, economical and construction efficiency. In this research, model tests for in-situ Top-Base system are carried out in other to the investigate the load delivering mechanism and the effect of bearing capacity.

  • PDF

현장정재하시험 결과를 통한 타입말뚝 지지력 판정법 비교 연구 (A Comparative Study on the Evaluation of Bearing Capacity for Driven Pile in Static Load Test)

  • 천병식;서덕동;최헌길;윤환호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.677-686
    • /
    • 2005
  • The allowable bearing capacity of a pile, the most important factor in stability estimation, is determined by applying safety factor to the ultimate load or yield load. There are several but contradictory methods available in current design codes to estimate the allowable bearing capacity and the safety factor. This paper analyzes load-settlement curves obtained from 19 static load tests measured from 11 sites. At all tests, the load is applied until apparent failure is observed. The validity of the ultimate and yield load estimation method and load caculated from the settlement criterion is investigated through comparison with the measured data. In addition, a new procedure to estimate allowable load and safety factor is proposed. Additional data from field static load tests, such as those incorporated in this study, are needed to more reliably apply the proposed method in design practice.

  • PDF

전기동역학을 이용한 해성 점토 지반내의 말뚝 마찰지지력 향상에 관한 연구 (A Study of Improvement Pile friction in Marine Clay using Electrokinetics Treatment)

  • 이광열;구태곤;;현재덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.211-218
    • /
    • 2004
  • The objective of this study is to enhance the ultimate bearing capacity of piles embedded in marine clay by electrokinetic(EK). The focus of improvement is at interlace between soil and pile. A series laboratory test was performed in EK cell. In each of test, the pile in the centre as anode is surrounded by cathode and it was installed in the vicinity of pile with triangular layout. The pile was made by stainless and embedded with 30cm of depth. Afterward, the DC voltage was applied to electrode over period of time. It caused flowing water from anode to cathode, thus the soil in the center of box has higher bearing capacity value than in the side of box has. It is shown by increasing of un-drained shear strength(Cu) near the pile and also ultimate bearing capacity of pile increase after EK treatment. In the future work, the continuous of this study is finding the effective DC voltage and makes EK treatment more applicable in the field.

  • PDF

탑다운 기초 현장타설말뚝의 지지력 평가 (Bearing Capacity Evaluation of Drilled Shaft for Top & Down Method)

  • 조천환;김홍묵;김웅규;권세오;성병완
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.58-65
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a Quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method.However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. It may be a small scale test pile could be an alternative as a quality assurance for the drilled shaft with high capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

  • PDF

정재하시험 결과를 통한 타입말뚝 지지력 공식의 타당성 분석 (A Study on the Applicability of Bearing Capacity Formulas of Driven Pile by Comparison with the Results of Static Loading Tests)

  • 천병식;이승범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.544-551
    • /
    • 2004
  • Piles are structural elements made of steel, concrete or timber, and utilize as pile foundation which is one of deep foundations. Driven pile among them, which drives pile into the ground, is fast-constructable, less expensive and it supplies much bearing capacity. For these reasons, its demand is steady. In this study, by selecting the cases which reached ultimate failure during in-situ static loading tests, bearing capacities acquired from these tests were compared with those computed by existing theories and formula. As the results of the analysis, ultimate bearing capacity computed by theoretic formula were less or similar to those of test results in most cases, but lower ground water level and more dense layer where end of piles were reached remarkably high bearing capacity in theoretical methods. ${\beta}-method$ and Korean structure foundation design standard were sensitive to ground physical properties. Meyerhof metbod and API code were relatively independent from site condition.

  • PDF

단일 쇄석다짐말뚝의 지지력 특성과 주요 설계 파라미터에 관한 고찰 (The study on the Characteristics of Ultimate Bearing Capacity and Major Design Parameters for Single Stone Column)

  • 천병식;김원철;조양운
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.552-560
    • /
    • 2004
  • Stone column is a soil improvement method and can be applicable for loose sand or weak cohesive soil. Since the lack of sand in Korea, stone column seems one of the most adaptable approach for poor ground as a soil improvement method. However, this method was not studied for practical application. In this paper, the most effective design parameters for the being capacity of stone column were studied. The parametric study of major design factors for single stone column was carried out under the bulging and general shear failure condition, respectively. Especially, a test result of single stone column by static load was compared with the bearing capacity values of suggested formulas. The analysis result showed that the ultimate bearing capacity by the formula was much less than the measured value by the static load test. Especially, the result of the parametric study under general shear failure condition showed that the bearing capacity has apparent difference between each suggested formulas with the variation of the major design parameters. Therefore, the result of this study can be a suggestion which is applicable for the field test and the future research.

  • PDF

접합요소를 도입한 기초지반의 유한요소해석 (The Finite Element Analysis of Foundation Layer by Introducing Interface Element)

  • 양극영;이대재
    • 한국전산구조공학회논문집
    • /
    • 제15권1호
    • /
    • pp.9-20
    • /
    • 2002
  • 본 연구의 목적은 비선형 흙-구조물 상호 작용문제를 연구하기 위한 계산 절차를 개발하는 것이다. 흙-구조물 상호 작용 거동을 연구하기 위하여 연직과 수평하중을 동시에 받은 대상기초와 강널말뚝으로 보강된 기초지반에 대한 유한 요소 수치해석을 하였으며 흙과 기초구조물 사이의 상호작용 거동을 모델하기 위하여 접합요소를 사용하였다 주 해석 결과는 다음과 같다. 1. 침하와 측방변위의 예측에 대해서는, 접합요소를 사용한 결과가 더 큰 값을 얻었다. 2. 극한지지력 결정에 대해서는 접합요소를 사용한 경우가 약 12%정도 더 작게 나타났다 3. 대상기초의 수평과 연직변위는 접합요소의 영향을 받았다.

동재하시험에 의한 모래자갈층에 근입된 매입말뚝의 지지력 산정 (The Estimation of Bearing Capacity of Auger-drilled Pile in Sand-Gravel by Dynamic Load Test)

  • 최기철;문유호;오원근;천병식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1819-1826
    • /
    • 2007
  • This study results of performed field load test in order to estimate the best pile length assessment and allowable bearing capacity of the pile foundation. End of initial driving(EOID) and restrike of pile dynamic loading tests were performed to calculate allowable bearing capacity of the experimental pile side and results were compared with the allowable bearing capacity estimated by theory. The results of allowable bearing capacity by EOID test is $1.08{\sim}1.21$ in the range of compared to the capacity calculated by the Structure Foundation Design Criterion. Allowable bearing Capacity by restrike of pile dynamic loading test is $1.32{\sim}1.48$ in the range of compared to the Structure Foundation Design Criterion. The Foundation Design Criterion underestimated the pile capacity. If the bearing capacity calculated by Structure Foundation Design Criterion is 100, EOID of pile dynamic loading test is 116, restrike of pile dynamic loading test is 138 for 20m pile used in this experimental.

  • PDF

사질토지반에서 짧은 쇄석다짐말뚝의 배치형태에 따른 지지력특성에 관한 연구 (A Study on the Characteristics of Bearing Capacity for Rammed Aggregate Pier in Sand)

  • 천병식;김영훈;류우현;김종환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.195-198
    • /
    • 2009
  • Rammed Aggregate Pier method is intermediate foundation of deep and shallow foundation, it has been built on world wide. But the investigation and research in domestic is not accomplished. In this paper, examined details of different spacing of piles, bearing capacities, respectively, conclude with recommendations on how RAP can be used in future needs. This documentation further provides comparisons of the laboratory test results which were obtained from differenciate the spacing of piles, namely installed rammed aggregate pier. Strain control test was conducted to determine the bearing capacities of the piers; 20mm, 30mm and 40mm diameter drilling equipment to drill holes were installed in sand at initial relative densities of 40%. By comparing different spacing of piles, in this experiment, piles are spaced structually span, form a ring shape, narrowing the distance of each other, to the center. the result shows that as diameter of pier is bigger in diameter, bearing capacity also dramatically increased due to raised stiffness. Also, the space between each piers narrowed, settlement rate of soil was decreased significantly. From the test results, as the space between each piles were getting closer, allows greater chances to have resistance to deformation, shows improved stability of structures.

  • PDF

조립질 입자크기가 전단강도에 미치는 영향 (A Study on Shear Strength of Granular Due to The Various Particle Size)

  • 이승호;서현길
    • 한국지반환경공학회 논문집
    • /
    • 제13권4호
    • /
    • pp.71-76
    • /
    • 2012
  • 흙의 전단강도는 흙 속의 임의의 면을 따라 발생하는 파괴와 활동에 저항하는 힘으로 흙의 공학적 특성 중에 가장 중요한 요소 중의 하나이다. 전단강도는 앝은 기초나 말뚝의 지지력 해석방법과 같은 기초공학의 문제나 댐 및 절 성토 후의 사면안정, 그리고 토류 구조물의 횡토압과 같은 흙의 안정 문제 해석 등에 이용된다. 본 연구는 화강풍화토에서 점성토 성분을 제거하고 건조시킨 후, 2 00mm(10번체)와 0 85mm(20번체), 0 475mm(40번체)로 분류한 시료로 직접전단시험기를 이용하여 전단강도 변화를 파악하고자 하였으며, 또한 산호모래를 선정하여 비교 시험을 실시하였다. 따라서 본 연구는 입자의 크기에 따른 전단강도 특성을 비교한 연구에 도움이 될 것으로 판단된다.