• Title/Summary/Keyword: 막 오염 지수

Search Result 17, Processing Time 0.025 seconds

Characteristics of Membrane Permeability on the Separation of Solid in a Liquid Livestock Manure (축분액비의 고액분리에 있어서 분리막의 투과특성)

  • 황명구;차기철;이명규
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.175-184
    • /
    • 2000
  • A lab-scale MF membrane reactor was installed to investigate the membrane permeability, characteristics of membrane fouling at each conditions, and quality of permeate (liquid livestock manure) in the separation of solid-matters using membrane. Experiment was divided three filtration type such as follows; continuous filtration, gravity filtration, and intermittent filtration. As a result of experiment, flux 1 LMH was maintained for 7days, and trans-membrane pressure(TMP) was increased gradually under 10cmHg, but it was increased immediately after 10cmHg, respectively. However, the flux was increased, the Tmax was decreased exponential more and more. During the pure-flux test, most of the fouling of membrane was reversible. At the gravity filtration, permeate could be obtained as 1.75 LMH for 3.5days without any other electronic pressure. As an investigation of membrane surface, this study could be decided that the reason of fouling at the lower flux (Run 1 and 2) was attached matters in membrane surface, but at the higher flux (Run 4-6) was concentration polarization.

  • PDF

Study on liquified waste(NaOH) separation/recovery and reuse from textile mercerization process by combined membrane filtration technology (복합여과막 기술을 이용한 머서라이징공정에서 발생되는 가성소다 폐액의 분리회수 및 재활용에 관한 연구)

  • Ryu, Seung-Han;Lee, Sang-Hun;Shin, Dong-Hoon;Park, Joon-Hyung;Jo, Suk-Jin;Lee, Sun-Ho;Ryu, Choong-Ki;Park, Wan-Sik
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.119-119
    • /
    • 2012
  • 섬유염색산업 중 면섬유의 염색과정에서 발생되는 머서라이징 폐액은 폐수처리장의 pH(수소이온농도)를 올리는 주원인이 되고 있어, 높은 pH에 따른 폐수처리 부과금이나 황산을 이용한 폐수 중화에 사용되는 약품비용이 과다하게 소요되고 있으며, 머서라이징공정에 사용되는 약품인 가성소다 비용이 계속 증가하고 있어, 기업의 환경처리비용 및 약품소모비용에 대한 부담이 매우 큰 실정이다. 본 기술은 머서라이징 폐액에 멤브레인 공정에 적용하여 폐가성소다로부터 가성소다를 회수할 뿐만 아니라, 회수된 가성소다를 다시 머서라이징 공정에 재이용할 수 있도록 하여 약품 절감효과 뿐만 아니라 폐수의 발생량과 오염물질의 농도의 획기적인 저감이 가능한 것이다. 본 연구에서는 서로 다른 기공크기를 갖는 막을 적용하여 투과플럭스, 부피회수율, 부유물질 및 유기물 제거율, 가성소다회수율, 파울링지수 등을 고려하여 폐수 특성에 맞는 가장 적합한 막을 선정하고, 각각의 막에 대하여 온도조건, 압력조건, 화학세정 등의 운전변수를 최적화, 고효율 폐알카리 회수 장치의 경제성 및 기술적 타당성 평가를 통한 가성소다 회수공정을 구성하였다.

  • PDF

Study on Hydrate Kinetic of $CH_4+CO_2$ and $CH_4+CO_2+N_2$ System ($CH_4+CO_2$ System과 $CH_4+CO_2+N_2$ System의 Hydrate Kinetic 비교 연구)

  • Shin, Hyungjoon;Moon, Donghyun;Han, Kyuwon;Lee, Jaejung;Lee, Juho;Yoon, Jiho;Lee, Gangwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.219.1-219.1
    • /
    • 2010
  • 매립지에서 유기물의 분해로 발생되는 매립가스는 악취 등으로 인한 대기오염뿐만 아니라 온난화지수가 21인 메탄이 약 50vol% 포함되어 있어 지구온난화에 큰 영향을 미친다. 하지만 매립가스를 에너지원으로 활용하면 대기오염저감, 지구온난화 감소, 대체에너지원 확보뿐만 아니라 CDM사업 등과 연계하여 부가수익창출이 가능하다. 현재 국내에는 약 242개의 폐기물매립지가 있는데, 이중 매립가스를 활용하는 곳은 단지 14개소로 개별 경제성이 있는 대형매립지에서만 자원화시설을 설치하여 운영 중이며 그 외 매립지에서는 매립가스를 소각 또는 단순 대기 방출하여 대기오염유발과 동시에 대체에너지원 미활용으로 국가차원에서 큰 손실이므로 이를 활용할 수 있는 기술개발이 시급하다. 본 연구에서는 중소규모 매립지에서 발생하는 매립가스를 중심적환장으로 이송하여 경제성을 가지는 에너지원으로 활용할 수 있는 기술개발을 목표로 하이드레이트 기술을 접목한 기초연구를 수행하였다. 매립지에서 매립가스가 생성되는 과정에 표층부의 균열 및 차수막의 손상과 포집하는 공정에서 블로워 등의 사용으로 질소가 다량 포함되며 질소의 경우 상당히 높은 압력과 낮은 온도에서 하이드레이트를 형성하므로, 매립가스 하이드레이트 형성시 질소의 영향에 대해 알아보았다. $CH_4+CO_2$ System과 $CH_4+O_2+N$ System에 대하여 각각의 실험조건에서 Kinetic을 측정하였으며, 실험전후의 가스 조성을 Gas Chromatography로 정성, 정량 분석하였다. 실험결과 매립가스에 공기가 유입될 경우, 질소의 영향으로 하이드레이트 생성조건이 가압되었고 하이드레이트 내 메탄의 함량비율이 줄어들었다.

  • PDF

Comparison and application method of seawater desalination pre-treatment process (해수담수화 전처리공정 비교 및 적용 방법)

  • Lim, Hwankyu;Kim, Seunghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.437-446
    • /
    • 2019
  • Reverse osmosis seawater desalination facilities can extend the cleaning cycle and replacement time of the reverse osmosis membrane by pretreatment process. Selection of pretreatment process depends on water quality. It was attempted in this study to select approriate pretreatment process for the Masan bay, which was high in particles and organic content. For this purpose, performances of pretreatment processes such as filter adsorber (FA), pore controllable fiber (PCF), and ultrafiltration (UF) were compared based on the silt density index (SDI). The SDI value of the filtrate should be less than 3. The study results showed that UF can produce the filtrate quality satisfying the requirement. However, the transmembrane pressure (TMP) of UF increased quickly, reaching 0.6 bar within 4 days. In order to secure stable operation, FA and PCF were combined with UF. The study results showed that combination of PCF and UF was able to extend the filtration duration (more than 2 months) until to reach TMP of 0.6 bar.

Meta-Analysis of Risk Factors for Contamination of Environmental Waters by Legionella (환경수계 레지오넬라균 오염 지표의 메타분석)

  • Zo, Young-Gun
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.424-428
    • /
    • 2013
  • To identify risk factors for Legionella contamination, water quality variables routinely measured in examination of natural and city waters were meta-analyzed for significance of correlation to Legionella incidences. For evaluation of abundance of Escherichia coli as a risk factor, which is currently used as an indicator of Legionella contamination in an official guideline in Korea, odds ratio (OR) of above-cutoff total coliform counts for Legionella presence/absence was used as the effect size in the meta-analysis. The OR was estimated as 1.05 (0.36-3.12, 95% CI), and the probability of having identical odds reached 0.92. Also, ORs from individual studies showed significant heterogeneity (P=0.008), which contributed to 63% of total variance of the ORs. In the case of heterotrophic plate count (HPC), the OR for Legionella presence/absence was 2.72 (2.04-3.63) with highly significant deviation from identical odds (P<0.0001). ORs from different studies were seemingly homogeneous ($Q_{df=8}$=12.7, P=0.12). Turbidity and concentrations of chlorine, iron ion and cupper ion were other routine variables that could be considered as risk factors. However, statistical measures from different studies were not uniform enough to develop an appropriate effect size while the number of studies reporting the variables was also small (3-5). In conclusion, HPC appeared to be appropriate as indicator of Legionella contamination, rather than fecal bacteria contamination. HPC may imply abundance of habitats (amoebas and biofilms) of Legionella in water. This result warrants further studies for standardizing protocols and cutoff values to infer Legionella risks from HPC.

Relationship Between Standardized Precipitation Index and Groundwater Levels: A Proposal for Establishment of Drought Index Wells (표준강수지수와 지하수위의 상관성 평가 및 가뭄관측정 설치 방안 고찰)

  • Kim Gyoo-Bum;Yun Han-Heum;Kim Dae-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.3
    • /
    • pp.31-42
    • /
    • 2006
  • Drought indices, such as PDSI (palmer Drought Severity Index), SWSI (Surface Water Supply Index) and SPI (Standardized Precipitation Index), have been developed to assess and forecast an intensity of drought. To find the applicability of groundwater level data to a drought assessment, a correlation analysis between SPI and groundwater levels was conducted for each time series at a drought season in 2001. The comparative results between SPI and groundwater levels of shallow wells of three national groundwater monitoring stations, Chungju Gageum, Yangpyung Gaegun, and Yeongju Munjeong, show that these two factors are highly correlated. In case of SPI with a duration of 1 month, cross-correlation coefficients between two factors are 0.843 at Chungju Gageum, 0.825 at Yangpyung Gaegun, and 0.737 at Yeongju Munjeong. The time lag between peak values of two factors is nearly zero in case of SPI with a duration of 1 month, which means that groundwater level fluctuation is similar to SPI values. Moreover, in case of SPI with a duration of 3 month, it is found that groundwater level can be a leading indicator to predict the SPI values I week later. Some of the national groundwater monitoring stations can be designated as DIW (Drought Index Well) based on the detailed survey of site characteristics and also new DIWs need to be drilled to assess and forecast the drought in this country.

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF