• Title/Summary/Keyword: 막오염 저항

Search Result 94, Processing Time 0.02 seconds

Analysis of Hydrophobic Membrane Fouling on the COD Loading Rates at the State of Passive Adsorption in Membrane Bioreactor (생물학적 막분리 공정에서 수동흡착 상태에서의 유기물 유입 부하에 따른 소수성 막의 오염도 분석)

  • Park, Tae-Young;Choi, Changkyoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.152-158
    • /
    • 2015
  • This paper investigated the membrane fouling potential at the state of passive adsorption which is no permeation with the test modules on COD (Chemical oxygen demand) loading rates, examined the recovery rate and resistance on membrane fouling by three cleaning manners of hydrophobic membrane in a bioreactor. The results showed that high COD loading led to the increase of extra-cellular polymeric substances and filtration resistance. The permeability resistance from 1st day to 63rd day was getting increased, however, the value of permeability resistance after 63th day during the operation period was almost same level at three COD loading rates, it was due that the biomass adhesion on membrane surface at the state of passive adsorption reached to the critical state. Also, the final recovery rates after three cleaning manners were 78%, 72% and 69% at the COD loading concentrations of 250 mg/L, 500 mg/L and 750 mg/L respectively, and then recovery rate by physical cleaning at Run 2 and Run 3 was decreased after 40th day, it proved that biomass cake, which is not easily removed, was formed on the membrane surface because of high COD loading rate and EPS concentration.

Characterization of the Nano-material U Membranes with Excellent Fouling Resistance (막 오염 저항성이 우수한 나노 소재 정밀 여과막의 특성 연구)

  • Choi Jeong Hwan;Lee Jeong Bin;Kim In-chul
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.289-296
    • /
    • 2005
  • In the MBR process, the membrane fouling occurs seriously on the membrane surface. In general, the membrane fouling is attributed to factors such as deposition or adhesion of sludge floc. The occurrence of fouling is a main cause of a decrease in membrane module fluk. At this study, our MBR membrane is manufactured by nano-particle with excellent anti-fouling character. The fine nano-material which can repel the sludge Hoc from the membrane surface is distributed in the membrane surface. We confirm anti-fouling effect, test continuously in the pilot site.

마찰계수에 관하여

  • 신효철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1986.11a
    • /
    • pp.29-41
    • /
    • 1986
  • 마찰계수는 서로 접촉하여 운동하는 두 물체간의 특성으로 간주되며 일반적으로 상대속도나 작용하중에 별로 영향을 받지 않는 것으로 알려져 있다. 화학적으로나 물리적으로 오염되지 않은 깨끗한 금속간의 마찰실험의 경우, 이 실험이 불활성 가스나 진공내에서 행해질 경우 상당히 큰 마찰저항을 경험하게 되나, 공기중에서의 실험에서는 작은 마찰저항이 기록되어 산화막이나 다른 오염물에 의해 형성된 막이 마찰저항을 감소시킨다고 보고 있다.

  • PDF

Liquid Velocity and Local Fouling in Coagulation-submerged Microfiltration Module for Drinking Water Treatment (정수처리를 위한 응집-침지식 정밀여과 모듈의 유체유속 및 국부오염)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.268-275
    • /
    • 2015
  • Effects of aeration intensity on local fouling were investigated in submerged membrane modules. Higher liquid velocities were observed at the section with the lower fiber packing density. The liquid velocity is increased with increasing the gas-liquid injection factor. The high shear stress coincided with the high liquid velocity. The shear stress increases with the increasing of gas-liquid injection factor and the liquid velocity improves with the increasing of gas-liquid injection factor. Irreversible fouling resistance ($R_{ir}$) of the fiber position is significant in a local region of high suction pressure near the suction point of the fiber (position 1). The ratio of $R_{ir}/R_m$ and $R_{ir}/R_r$ of position 1 was highest compared to the position 2 and 3. Irreversible fouling resistances results confirmed the preferential deposition of foulants near the suction part of the fiber where the local suction pressure is the highest and correspondingly, more particles are accumulated to the membrane surface. The effects of local fouling along the fiber length are significant factors to optimize the design of submerged modules.

The Effect of Support Material of Ceramic MF Membrane on the Fouling and backwashing Efficiency (세라믹 정밀여과막의 지지체 재질이 막오염과 역세척 효율에 미치는 영향)

  • 김재홍;이호상;이정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04b
    • /
    • pp.39-39
    • /
    • 1997
  • 김치산업에서 원재료의 염적공정중에 발생하는 폐염적수를 처리하여 염적공정에 재사용하는 새로운 시스템을 개발하였다. 관형 정밀여과막을 사용한 본 연구에서 막오염의 감소와 높은 막투과유속의 유지를 위하여 산역세척과 투과수역세척이 도입되었고 대상이 되었던 세공크기가 비슷한 4종류의 막(Carbosep M14, Membralox Z100, Membralox A200, Microdyne MD020TP 2N)에 대하여 역세척의 효율이 각각 다르게 나타났다. 특히 지르코니아 재질의 막 표면과 탄소재질의 지지체로 이루어진 Carbosep M14 세라믹막은 투과수역세척시에 역세척을 하지 않았을 때 보다 오히려 투과유속이 감소하는 특이한 현상이 관찰되었고 이러한 역세척 효율의 차이의 원인을 규명하기위한 연구가 진행되었다. 4종류의 막에 대하여 전처리된 폐염적수의 여과시 진행되는 막오염 메카니즘을 알아보기 위하여 문헌에서 잘 알려진 4가지의 여과모델식을 적용하여 보았고 직렬여과저항모델을 이용하여 여과저항을 세분하여 측정하였다. 모델식의 적용결과 역세척의 효율이 좋은 3종류의 막에는 막표면의 케이크형성이 주된 투과유속의 감소원인임을 알아내었고 carbosep M14 막은 용존유기물의 비가역적인 흡착과 세공막힘이 주된 원인임을 알 수 있었다.

  • PDF

Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation (금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2004
  • Total resistance of membrane in a micro-filtration system using a metal membrane was mainly attributed to the permeate resistance of cake layer($R_c$), which was formed by deposited particles from the physico-chemical interactions of solids on membrane surface. Intermittent back ozonation was highly effective than the air backwashing for fouling reduction. As far the operational effect, under same ozone injection, the increase of gas flow-rate was more favorable than the increase of injection time far the recovery of permeation flux. As the filtration time was longer, the effect of flux recovery by intermittent back-ozonation decreased. Therefore, it is preferable to operate membrane cleaning before the foulant is consolidated on membrane surface.

상수처리에서 유기,무기물이 한외 여과막 오염에 미치는 영향

  • 오중교;이태진;이용택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.62-63
    • /
    • 1996
  • 상수처리 시스템엣의 분리막의 적용시 효과적인 공정운영을 위해 여러가지 운전조건이 있으나 막내에 축적되는 막오염이 주요문제로 인식되고 있다. 막오염은 막 표면이나 세공에서 물질의 흡착, 부착 및 축적등과 같은 일련의 메카니즘에 의해 물의 유속을 저하시키는 결과를 초래하며 분리막 공정에서 커다란 경제적 손실을 가져다 줄 수 있으므로 막오염을 조절할수 있는 인자들의 제어는 실플랜트에서 중요한 과제이다. 분리막을 이용한 상수처리 시스템에서의 운전 조건들은 온도, 압력, 선속도, pH등이 있으며 안정적이며 경제적인 투과 flux를 위해서는 실험실적 규모를 통해 최적 조건을 선정해 주어야 한다. 따라서 본 연구는 이러한 막오염을 제어하고 최적 운전조건을 선정하기 위해 상수원수로 호소수에 포함되어 있는 유기물의 대부분을 차지하리라 생각되는 humic acid와 무리물질인 kaolin을 모사용액으로 제조하여 막오염과 운전조건과의 상호작용을 cake 저항, 비저항 값으로 측정하여 장기간의 field test에 필요한 최적 운전조건을 선정해 주었다.

  • PDF

Effect of Current Density and pH of Electrolyte on Anion-Exchange Membrane Fouling (전류밀도와 전해질의 pH가 음이온교환막의 막 오염에 미치는 영향)

  • Choi, Jae-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.965-969
    • /
    • 2005
  • Current density is an important operating parameter in the ion-exchange membrane process. We observed the effects of fouling of a Neosepta AMX anion-exchange membrane(Tokuyama Soda, Japan) in 0.02 M NaCl solution containing 100 mg/L sodium humate. Membrane fouling was analyzed by measuring the change in the electrical resistance in the under- and over-limiting current density regions. The experimental results found that membrane fouling was negligible at under-limiting current densities, but was increased significantly when an over-limiting current was supplied. After the fouling experiments, the current-voltage curves for the fouled membranes were measured. From the curves, we observed increased electric resistance and reduced limiting current density(LCD), caused by the accumulation of humic acid on the membrane surface. Furthermore, membrane fouling increased as the acidity of the electrolyte solution containing humic acid increased. This occurred because the fouling of an anion-exchange membrane is affected more by the physicochemical properties of the humic substance than by the surface charge of the humate.

Factors Affecting Membrane Fouling in Membrane Filtration of Activated Sludge (막결합형 활성슬러지 시스템에서의 막오염 유발 인자)

  • Chang, In-Soung;Lee, Chung-Hak
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.323-329
    • /
    • 2000
  • The coupling of an activated sludge reactor with a membrane unit, i.e., Membrane Coupled Activated Sludge (MCAS) system offers several advantages over conventional process. But the major hurdle in the extensive use of this process is the continuous reduction of permeation flux caused by membrane fouling. The aim of this study is to investigate membrane fouling characteristics in the MCAS process. During crossflow ultrafiltration(CFUF) of activated sludge, floc size decreased abruptly at the beginning of operation and thereafter decreased continuously and gradually. The floc size changed from 100~200 to $6{\sim}8{\mu}m$ depending on recirculation velocity. This floc breakage played a key role in rapid increase of $R_c$(cake layer resistance), which led to flux decline. The floc breakage stimulated biomass to release EPS(Extracellular Polymeric Substance) which has been known to be one of the major membrane foul-ants. The amounts of EPS before and after CFUF were 266 and 405(VS mg/MLSS g), respectively. The rise up of EPS concentration was another factor affecting flux decline in MCAS system.

  • PDF

Back Flushing Behavior of Microfiltration Membrane Fouled by Alumna Colloidal Suspensions (알루미나 현탁액에 의해 오염된 정밀여과막의 역세척 거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.34-46
    • /
    • 2009
  • Effect of backflushing on the membrane fouling for polyethylene capillary membranes was examined by measuring the flux of $Al_2O_3$ colloidal suspensions through the cross flow microfiltration. In the comparison of with and without the application of backflushing, the hydraulic resistance to permeate flow of the suspension was less with backfluslng, but the Increasing rate in permeate resistance was higher. Regardless of backflushing, the cake filtration was dominant at the initial period of filtration with backflushing, being followed by the pore blocking. And at steady state, the fouling mechanism is almost governed by the cake filtration model. On the contrary, the pore blocking preceded the cake filtration in the initial stage of the original membrane before backflushing. And irrespective of backflushing, the ratio of cake filtration to total fouling increased, compared with that fur before backflushing. For the membrane with $0.24{\mu}m$ pore size, the permeate resistance was higher than that of $0.34{\mu}m$ pore size membrane. but the ratio of cake filtration was smaller than that of large pore membrane. In comparing the ratio of each fouling component to the total fouling for the case with backflushing pore blocking was 7.8% and cake filtration was 92.2%. for the case without backflushing, total fouling was composed of 9.6% pore blocking and 90.4% cake filtration.