• Title/Summary/Keyword: 마찰형 감쇠

Search Result 24, Processing Time 0.03 seconds

Control Effectiveness of Shear Walls Connected by Beams with Friction Dampers (인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과)

  • Chung, Hee-San;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.105-115
    • /
    • 2009
  • Numerical analysis of shear walls governed by flexural behavior is conducted for the seismic control performance of proposed friction dampers installed at the center of coupling beams. Control effectiveness of shear walls connected by beams with the proposed dampers are compared for single shear wall with same flexural rigidity. Average responses of the shear walls with the dampers are found with seven scaled-downed earthquakes based on KEC 2005 design spectrum. Slip load is the most important design parameter. It is designed to be 5, 10, 20, 30, 60, 90% of total vertical shear force at damper location to prevent damper slip in specific stories. Nonlinear time-history analysis is conducted by using SeismoStruct analysis program. Seismic control performance of the dampers is evaluated for base shear, energy dissipation, curvature and top-floor displacement. Results show that the dampers are the most effective in reducing the responses when their total slip load is 30% of total vertical shear force.

Equivalent damping ratio of a friction damper installed in a structure under collapse load (붕괴하중을 받는 건물에 설치된 마찰감쇠기의 등가감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.602-605
    • /
    • 2011
  • 본 논문에서는 마찰감쇠기가 설치된 건물이 붕괴하중을 받을 때의 에너지소산능력을 고려하여 등가감쇠비를 유도하였다. 마찰감쇠기는 주로 지진과 같은 수평하중에 대한 에너지를 소산하기위해 설치된다. 마찰감쇠기를 대각 가새형으로 설치하면 수평하중에 대한 저항력뿐 만아니라 수직하중에 대한 저항성능도 발휘된다. 건물에 설치된 마찰감쇠기는 외력의 크기에 따라 정지와 운동의 상태를 반복하여 외부 입력에너지를 소산시키기 때문에 외력과 응답관계가 비선형이다. 건물은 고유의 점성감쇠를 가지므로 마찰감쇠기가 설치된 건물은 마찰과 점성감쇠를 동시에 고려해야하므로 해석적인 정해를 구하기가 어렵다. 에너지 평형을 이용하여 등가감쇠비를 구하고 운동방정식을 등가선형화하면 쉽게 저항 성능을 파악할 수 있다. 우선 건물에 영향을 미치는 것은 감쇠이므로 감쇠의 영향력을 마찰력비, ${\gamma}_c$로 나타내었다. 둘째, 정해를 마찰력비로 표현하여 유도하고 응답특성을 파악하였다. 셋째, 에너지 균형식을 통해 등가감쇠비를 산정하였다. 마지막으로 등가감쇠비를 검증하기 위하여 등가감쇠비를 이용하여 등가선형화한 응답과 실제 마찰감쇠기를 설치하여 비선형 수치해석한 결과와 비교, 검증하였다.

  • PDF

Probability Distribution of Displacement Response of Structures with Friction dampers Excited by Earthquake Loads Generated Using Kanai-Tajimi Filter (Kanai-Tajimi 필터 인공지진 가진된 마찰형 감쇠를 갖는 구조물의 변위 응답 확률분포)

  • Youn, Kyung-Jo;Park, Ji-Hun;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.623-628
    • /
    • 2007
  • The accurate peak response estimation of a seismically excited structure with frictional damping system(FDS) is very difficult since the structure with FDS shows nonlinear behavior dependent on the structural period, loading characteristics, and relative magnitude between the frictional force and the excitation load. Previous studies have estimated that by replacing a nonlinear system with an equivalent linear one or by employing the response spectrum obtained based on nonlinear time history and statistical analysis. In the case that an earthquake load is defined with probabilistic characteristics, the corresponding response of the structure with FDS has probabilistic distribution. In this study, nonlinear time history analyses were performed for the structure with FDS subjected to artificial earthquake loads generated using Kanai-Tajimi filter. An equation for the probability density function (PDF) of the displacement response is proposed by adapting the PDF of the normal distribution. Finally, coefficients of the proposed PDF are obtained by regression analysis of the statistical distribution of the time history responses. Finally the correlation between PDFs and statistical response distribution is presented.

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.

Evaluation of Damping Properties on Suspension Bridge Using Extended Kalman Filter (확장형 칼만필터를 이용한 현수교의 감쇠성능 평가)

  • Park, Dong-Uk;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.89-96
    • /
    • 2011
  • The damping ratio as an index of bridge vibration could be considered as one of the important dynamic characteristics of a suspension bridge. But estimating of damping ratio on an existing suspension bridge under ambient vibration condition could be a laborious task. Moreover, it is not simple to directly distinguish aerodynamic damping and friction damping from apparent damping. According to previous studies, the aerodynamic damping properties can be linearly affected by wind speed level, and apparent damping ratio can be affected by amplitude of vibration. Therefore, in this article, the relationships among damping ratio, wind speed level and amplitude of acceleration were studied for separating extract aerodynamic damping and friction damping from apparent damping. Damping ratios on Sorok Bridge, a suspension bridge which is a located in Go-Heung, Korea, were estimated by two different methods as using Hilbert transform and extended Kalman filter which were well known as effective estimation methods for non-linear state. It was possible to distinguish aerodynamic damping and friction damping from apparent damping using averaged normal components of wind speed, RMQ values of acceleration, and estimated damping ratios from wind-induced vibration responses and vehicle loading responses.

Shaking Table Test of a Full Scale 3 Story Steel Frame with Friction Dampers (마찰형 감쇠장치가 설치된 실물크기 3층 철골프레임의 진동대 실험)

  • Bae, Chun-Hee;Kim, Yeon-Whan;Lee, Sang-Hyun;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.862-873
    • /
    • 2007
  • Energy dissipation devices can be considered as an alternative for the seismic performance enhancement of existing structures based on the strengthened seismic design code. In this study, seismic response mitigation effects of friction dampers are investigated through the shaking table test of a full scale 3 story building structure. Frist, the bilinear force-displacement relationship of a structure-brace-friction damper system and the effect of brace-friction damper on the increase of frequency and damping ratio are identified. Second, frequency, displacement, and torque dependent characteristics of the friction damper are investigated by using harmonic load excitation tests. Finally, the shaking table tests are performed for a full scale 3 story steel frame. System identification results using random signal excitation indicated that brace-friction damper increased structural damping ratio and frequency, and El Centro earthquake test showed that brace-friction damper reduced the peak displacement and acceleration significantly. In particular, it was observed that the damping effect due to friction damper becomed obvious when the structure was excited by more intensive load causing frequent slippage of the friction dampers.

Comparison of Acoustic Attenuation Measurement Technique of Polyethylene Matrix Composite Materials (폴리에틸렌기재 복합재료의 음향감쇠 측정방법 비교)

  • Kim Kyongsub;Jung Hyun K.;Lee Zin-Hyoung;Hong Soon H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.265-268
    • /
    • 1999
  • 감쇠가 큰 고분자 복합재료에서 초음파 다중반사파를 이용한 Pulse Echo법, 공진주파수에서 내부마찰계수 측정법과 Rheometer를 이용한 동적탄성계수 측정법을 사용하여 음향감쇠계수를 측정하고 각각의 측정자료를 비교하는 연구를 수행하였다. Pulse Echo법을 이용하여 0.5, 1.0, 2.25MHz에서 음향감쇠계수를 측정하였고, 이때 폴리에틸렌기지 복합재료의 음향감쇠계수는 강화재의 부피분율에 따라 3-15dB/cm 정도로 큰 값을 나타내었다. 폴리에틸렌기지 복합재료를 600kHz 근처에서 공진주파수를 가지도록 시편을 만든 후에 내부마찰계수를 측정한 결과로 계산된 음향감쇠계수는 Pulse Echo 실험에서 구한 값과 잘 일치하는 결과를 얻을 수 있었다. Rheometer를 이용한 동적탄성계수 측정법은 0.1-100Hz의 주파수에서 측정한 자료를 TTSP 이론을 이용하여 1MHz의 결과와 비교하였는데, 단일 고분자 재료에서는 다른 측정방법과 음향감쇠계수가 일치하였지만 복합재료에서는 음향감쇠계수값이 일치하지 않는 결과를 나타내었다.

  • PDF

Response Spectra of Structure Installed Frictional Damping System (마찰형 감쇠를 갖는 구조물의 응답 스펙트럼)

  • Park, Ji-Hun;Youn, Kyong-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.893-897
    • /
    • 2006
  • Structures with additional frictional damping system have strong nonlinearity that the dynamic behavior is highly affected. by the relative magnitude between frictional force and excitation load. In this study, normalized response spectra of the structures with non-dimensional friction force are obtained through nonlinear time history analyses of the mass-normalized single degree of freedom systems using 20 ground motion data recorded on rock site. The variation of the control performance of frictional damping system is investigated in terms of the dynamic load and the structural natural period, of which effects were not considered in the previous studies. Least square curve fitting equations are presented for describing those normalized response spectrum and optimal non-dimensional friction forces are obtained for controlling the peak displacement and absolute acceleration of the structure based on the derivative of the curve fitted design spectrum.

  • PDF

Response Spectra of Structure Installed Frictional Damping System (마찰형 감쇠를 갖는 구조물의 응답 스펙트럼)

  • Park, Ji-Hun;Youn, Kyung-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.1 s.118
    • /
    • pp.88-94
    • /
    • 2007
  • Structures with additional frictional damping system have strong nonlinearity that the dynamic behavior is highly affected by the relative magnitude between frictional force and excitation load. In this study, normalized response spectra of the structures with non-dimensional friction force are obtained through nonlinear time history analyses of the mass-normalized single degree of freedom systems using 20 ground motion data recorded on rock site. The variation of the control performance of frictional damping system is investigated in terms of the dynamic load and the structural natural period, of which effects were not considered in the previous studies. Least square curve fitting equations are presented for describing those normalized response spectrum and optimal non-dimensional friction forces are obtained for controlling the peak displacement and absolute acceleration of the structure based on the derivative of the curve-fitted design spectrum.

Seismic Response Control of Structures Using Decentralized Response-Dependent MR Dampers (분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어)

  • Youn, Kyung-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.761-767
    • /
    • 2007
  • In centralized control system, complicated control systems including sensors, power supply and dampers should be required to satisfy the target response of large-scale structures. The practical applications of the centralized control system, however, is very difficult due to high order finite element model of structures, uncertainty of models, and limitations of the excitation system. In this study, the decentralized response-dependent MR damper of which magnetic field is automatically modulated according to the displacement or velocity transferred to the damper without any sensing and computing systems. this decentralized response-dependent MR damper are investigated according to the ranges of relative magnitude between the control force of MR damper and the story shear force of structures by nonlinear time history analysis. Finally, its performance is compared with centralized LQR algorithm which is used in general centralized control theory for a three story building structure.