Characteristics of Shear Behavior for Coarse Grained Materials Based on Large Scale Direct Shear Test (III) - Final Comprehensive Analysis - (대형직접전단시험을 이용한 조립재료의 전단거동 특성 (III) - 최종 종합 분석 -)

  • Lee, Dae-Soo;Kim, Kyoung-Yul;Hong, Sung-Yun;Oh, Gi-Dae;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.4
    • /
    • pp.39-54
    • /
    • 2009
  • Large scale direct shear tests were carried out to analyze the shear behavior of crushed rocks at local representative quarries. Shear strength for each specimen was derived and the effects on shear behavior induced by the variation of factors such as particle size, water immersion, density, uniformity coefficient, and particle breakage were evaluated and quantitatively compared with previous studies. The opportunity was also taken to identify stress-dilatancy relation of crushed rocks following the energy-based theory and friction coefficients at critical state as well as peak friction angles and dilation angles were estimated. As a result of tests it was found that uniaxial compressive strength and particle breakage of the parent rocks have crucial effect on internal friction angles; in addition, dilatancy at the failure showed strong relationship as well.

The development of gas seal lip technology on piston rod for reducing a friction force on moving gas spring elevation (가스 스프링 높이 조절에 있어 마찰력 감소를 위한 피스톤 로드에 작용하는 가스씰 조임 기술 개발)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7166-7175
    • /
    • 2015
  • This paper is a study on using gas springs for reduced friction in the elevation of the large television stand. Target is applied to the operation of the elevation over 50-inch television that uses a gas spring. Gas seal lip technology is needed for development acting on the piston rod in order to obtain a reduction in friction in elevation operation. In order to acting on the gas seal lip technology, the improved friction force can be obtained through the inner diameter of gas seal lip, the design of cutting angle and the changes of material.

Friction Factor of Seepage Flow (투수층흐름에서의 마찰계수)

  • 유동훈;권순국
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.6 no.4
    • /
    • pp.397-403
    • /
    • 1994
  • The seepage flow has been investigated conducting laboratory experiments mainly in order to determine the relation of seepage flow friction factor against Reynolds number. The apparatus of seepage flow measurements has the water flow almost horizontaly. Several sets of experiments were carried out, and various flow conditions were obtained in each set of flow. To cover wide range of flow conditions, used were various materials of different measurement sizes and various stages of water discharge in the seepage flow tests. Shape factor equation was developed using existing data, and based on the present laboratory data, an explicit equation was developed for the estimation of friction factor of seepage flow in the range of Reynolds number from about 1 to about 600. The same equation is expected for the flow condition of Reynolds number over 600, considering the trend of friction factor distribution.

  • PDF

Development of Brake Disk Materials with Ni-Cr-Mo (Ni-Cr-Mo계 제동디스크 소재 개발)

  • Goo, Byeong-Choon;Lim, Choong-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.188-194
    • /
    • 2008
  • Brake disks for rolling stock are exposed to thermal fatigue during braking, and thermal cracks occur on surface of disks. Thermal cracks can cause serious accidents, deterioration of braking performance and increase of maintenance cost due to frequent exchange of friction materials. In this study, candidate materials with high-heat resistance were selected by searching the literature. By using cast specimens made of the candidate materials, chemical composition, crystal structure and graphite type were analyzed. In addition, friction coefficient and wear were measured and compared with values for the disk material in service. As a result, it was shown that the NiCrMo has highest tensile strength and lowest friction coefficient and the disk material in service has the most stable friction characteristics.

A Numerical Analysis of the Shallow Water Equations Using the Multi-slope MUSCL (다중 경사 MUSCL을 이용한 천수방정식의 수치해석)

  • Hwang, Seung-Yong;Lee, Sam-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.158-158
    • /
    • 2011
  • 천수방정식과 같은 쌍곡선형 미분방정식의 불연속 해에 대한 Riemann 해법은, 1950년대 말 공기동역학 분야에서 S. K. Godunov의 선구적인 시도 이후, 다양한 영역에서 성공적으로 적용되고 있다. 당초 제안된 해법은 공간에 대해 1차 정도였으나, 2차의 정도를 얻을 수 있는 기법이 1970년대 말 B. van Leer에 의해 제안되었으며, MUSCL로 불린다. 서로 인접한 격자의 보존변수가 고려된 경사가 도입되어 두 격자에 의해 공유되는 변의 좌 우에서 선형으로 보존변수가 재구축되는 MUSCL은 제한자와 함께 이용될 때, 구조 격자 체계에서 비교적 단순하면서도 효과적인 적용성이 입증되었다. 그런데, 이 기법을 2차원의 비구조 격자 체계에 적용하는 경우, 인접한 모든 격자의 보존변수를 고려한 평면의 경사를 결정해야 하는 어려움이 따른다. 특히, 삼각형 비구조 격자에 적용할 경우 최적의 평면을 결정하기 위해 Green-Gauss 적분식이나 최소-자승법 등을 이용하게 된다. 이에 비해, 2010년 T. Buffard와 S. Clain이 제안한 다중경사 기법은 격자의 각 변에서 경사가 각각 결정되는 방법으로 계산량이 많은 Green-Gauss 적분식이나 최소자승법을 피할 수 있는 장점이 있는 것으로 알려져 있다. 정확해가 알려진 두 경우에 대해 몇 가지 제한자를 적용한 결과를 1차 정도의 해와 함께 비교하였으며, superbee 제한자에 의한 결과가 우수하였으나, 희유파와 충격파가 맞닿는 곳에서 수치 분산이 나타났다. minmod 제한자의 결과가 대체로 무난하였으며, 이를 2차원 댐 붕괴 문제에 적용하여 1차 정도의 해와 비교하였다. 마찰이 없고 초기 수심이 댐 상류에서 10 m, 하류에서 5 m로서 물이 차 있는 경우, 1차 정도의 해에서 나타나는 수치 소산이 2차 정도에서는 발생되지 않았다. 댐 하류에서 초기에 수심이 영으로 바닥이 드러난 경우에서 마찰의 영향을 검토하였다. 마찰이 있는 경우, 마찰 경사 항의 Manning 계수를 0.04로 두었으며, 마찰에 의한 영향이 잘 드러났다. 수심이 50 mm 보다 작은 경우에는 마찰을 적용하지 않았다. 이 연구는 환경부 '차세대 핵심환경기술개발 사업'의 지원에 의한 것이다.

  • PDF

Evaluation of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 교정선 사이의 마찰력)

  • Jeong, Tae-Jong;Choie, Mok-Kyun
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.613-623
    • /
    • 2000
  • The purpose of this study was to amount of the frictional forces with the brackets and wires, ligation methods, dry/wet, offsets, interbracket distances, velocity and to compare them each other by different conditions. This study tested 0.018'x0.025' slot sized 8 types of orthodontic bracket systems and 0.016', 0.016'x0.022' sized stainless steel, NiTi, Cu-NiTi orthodontic wires. One cuspid bracket were positioned on the slide glass and archwire was engaged into bracket and ligated with elastomeric modules. The values of frictional forces were measured with the instron universal testing machine. The results were as follows; 1. Polycrystalline ceramic bracket had the highest mean frictional forces and followed and by ceramic reinforced plastic bracket, metal bracket, plastic bracket with metal slot, monocrystalline ceramic bracket, single bracket, self-ligating bracket, friction free bracket in descending order. The self-ligating bracket showed low frictional forces in the round wires and high frictional forces in the rectangular wires. 2. Stainless steel wires had the least frictional forces and followed by NiTi, Cu-NiTi wires in descending order. Round wires had lower frictional forces then that of rectangular wires. 3. The stainless steel ligation method had significantly greater mean frictional forces them the elastomeric module ligation method. 4. Artificial saliva statistically increased the frictional forces in stainless steel wire, NiTi wire and Cu-NiTi wire. 5. There was a statistically significant difference with offset change 6. There was no statistically significant difference with interbracket distance in stainless steel wires but a significant difference in NiTi wires as the interbracket was decreased. 7 There was no statistically significant difference with velocity change. From the above findings, self-ligating bracket, stainless steel wires and the elastomeric module ligation method might be effective than any other materials to reduce the frictional forces in the orthodontic treatment and can be correlated to clinical situations seen in orthodontic patient care.

  • PDF

The comparison of the frictional force by the type and angle of orthodontic bracket and the coated or non-coated feature of archwire (교정용 브라켓의 종류와 각도, 호선의 코팅 여부에 따른 마찰력의 비교)

  • Jang, Tae-Ho;Kim, Sang-Cheol;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.399-410
    • /
    • 2011
  • Objective: The purpose of this study was to evaluate the difference in frictional resistance among metal, ceramic, self-ligation brackets and coated or non-coated Ni-Ti archwires at various bracket-archwire angulations during the sliding movement of an orthodontic archwire, using an orthodontic sliding simulation device. Methods: Four types of bracket (Micro-arch Perpect Clear2 Clippy-C and Damon3 and 5 types of orthodontic archwire (0.014", 0.016", and 0.016" ${\times}$ 0.022" inch coated Ni-Ti, and 0.016" and 0.016" ${\times}$ 0.022" inch Ni-Ti) were used. Further, the bracket- archwire angles were set at 4 different angulations: $0^{\circ}$, $3^{\circ}$, $6^{\circ}$, and $9^{\circ}$. Results: The frictions from all the experimental groups were found to be significantly increased in order of self-ligation brackets, Micro-arch and Perpect Clear2 ($p$ < 0.001). The presence of a coat had no effect on the friction of the same sized archwires at $0^{\circ}$ and $3^{\circ}$ bracket-archwire angles ($p$ < 0.001). Coated archwires had significantly higher frictions than the same sized non-coated archwires at $6^{\circ}$ and $9^{\circ}$ bracket-archwire angles ($p$ < 0.001). The frictions increased significantly as the bracket-archwire angles were increased ($p$ < 0.001). Conclusions: The use of self-ligation brackets will be beneficial in clinical situations where a low frictional force is required. Further, in cases where crowding is not severe, the use of coated archwires should not cause problems. However, more additional explanation is required considering the fact that the damage of coated archwire and exposure of the metal portion in case of binding and notching and the effects of saliva were not taken into account.

A Study on Frictioal Resistance Force of Orthodontic Resin Bracket (교정용 Resin bracket의 마찰 저항력에 관한 연구)

  • Lee, Won-you;Lim, Kyung-Soo
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.107-112
    • /
    • 1999
  • As increasing number of adult patients, the esthetic orthodontic appliances are needed. They are tooth-colored or translucent ceramic and resin brackets. Although ceramic and resin bracket have good esthetics, there are some disadvantage such as frictions. Recently, metal-reinforced resin bracket(MRBB) were introduced. The purpose of this study is to find frictional force of MRRB, ceramic bracket and resin brackets. There is few study in frictional force about metal reinforced resin bracket(MRRB). This study used 4 orthodontic wire(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$ and 5 brackets(one metal bracket, one ceramic bracket, one resin bracket, two MRRB). The following result is obtained using metal bracket(Ormco.Co., U.S.A), ceramic brackets($Crystalline^{\circledR}$), resin bracket( Clear Medium $Siamase^{\circledR}$). Following conclusions are obtained. 1. Ceramic and resin bracket have significantly more frictional forces than metal reinforced resin bracket and metal bracket. 2. There is no significant difference in frictional force according to the slot types of metal - reinforced resin brackets. 3. There is no significant difference in frictional force between metal reinforced resin bracket and metal bracket. 4.. Frictional force is decreased in S-S wire than TMA wire.

  • PDF

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.

Experimental Study of Interfacial Friction in NaBH4 Solution in Microchannel Dehydrogenation Reactor (마이크로채널 탈수소 화학반응기에서 수소화붕소나트륨 수용액의 계면마찰에 대한 실험연구)

  • Choi, Seok Hyun;Hwang, Sueng Sik;Lee, Hee Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.139-146
    • /
    • 2014
  • Sodium borohydride ($NaBH_4$) is considered as a secure metal hydride for hydrogen storage and supply. In this study, the interfacial friction of two-phase flow in the dehydrogenation of aqueous $NaBH_4$ solution in a microchannel with a hydraulic diameter of $461{\mu}m$ is investigated for designing a dehydrogenation chemical reactor flow passage. Because hydrogen gas is generated by the hydrolysis of $NaBH_4$ in the presence of a ruthenium catalyst, two different flow phases (aqueous $NaBH_4$ solution and hydrogen gas) exist in the channel. For experimental studies, a microchannel was fabricated on a silicon wafer substrate, and 100-nm ruthenium catalyst was deposited on three sides of the channel surface. A bubbly flow pattern was observed. The experimental results indicate that the two-phase multiplier increases linearly with the void fraction, which depends on the initial concentration, reaction rate, and flow residence time.