• Title/Summary/Keyword: 마이크로파 조사

Search Result 178, Processing Time 0.029 seconds

Kinetics on the Microwave Carbonization of Rice Chaff (왕겨의 마이크로파 탄화속도)

  • Kim, Ji Hyun;Ryu, Seung Kon;Kim, Dong Kook
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.683-690
    • /
    • 2005
  • The microwave carbonization of rice chaff was performed, and their kinetics were compared to those of conventional thermal carbonization. Thermal carbonization was carried out at $300-600^{\circ}C$ for 30 minutes. The weight loss and C/H mole ratio remarkably increased as increase of temperature, while there was no carbonization by microwave dielectric heating in spite of increasing incident power and irradiation time. However, microwave carbonization was successfully performed by addition of 6 wt% of thermal carbonized rice chaff, it's C/H mole ratio is larger than 3.0, as a catalytic initiator to uncarbonized rice chaff, and the kinetics was depended on the incident power and irradiation time, resulting in the coincide with thermal carbonization to the Arrhenius equation. The activation energy of microwave carbonization was quite low as compared to that of thermal carbonization, while the kinetic constant was large. This is due to the internal volumetric heating characteristics of carbonized rice chaff by microwave. The effect of ash, and C/H mole ratio and amount of carbonized rice chaff were investigated on microwave carbonization.

The Fixation Effects of Biological specimen Using Microwave Oven Equipped With Infrared-Temperature Sensor (적외선 온도감응기를 장착한 마이크로파 오븐의 생체물질 고정효과)

  • 신길상
    • The Korean Journal of Zoology
    • /
    • v.37 no.2
    • /
    • pp.144-155
    • /
    • 1994
  • 마이크로파 에너지로서 현미경 관찰을 위한 생체물질을 고정할 때, 고정효과는 화학 고정액을 사용할 때와 비교하여 보다 우수한 또는 적어도 동일한 고정효과를 볼 수 있다는 것은 알려진 사실이다. 그러나 기존의 마이크로파 오븐을 사용하여 생체물질을 고정하면 고정 정도에 일정성이 없는데, 이는 마이크로파가 균일하게 조사되지 않고 고정에 적절하도록 마이크로팍의 강도를 조절하기 어려우며, 이로 인하여 정확한 고정온도의 측정이 불가능하기 때문으로 생각된다. 이 연구에서는 마이크로파가 조사되는 동안 시료의 온도를 측정할 수 없는 기존의 마이크연.파 오븐의 단점을 보완하기 위하여 비접촉식 적외선 온도 감응기를 장착한 마이크로파 오븐을 개발하였으며 고정효과를 관찰하기 위하여는 포유류의 기준 조직으로 알려진 생쥐의 신장을 고정하였다 고정효과는 전체적인 구조와 세부 구조의 보존이 모두 우수하였고 최적의 고정온도는 28$\pm$1$^{\circ}C$(완충용액 20 ml, 10초) 이었다. 이와같이 고정된 재료는 고정효과 뿐만 아니라 염색성이 좋아서 조직화학 반응이 우수하고, 냉동절편법과 연계했을 때 전체 절편제작 과정이 2~4시간 내에 완료될 수 있었다 이때 절편의 질(질)은 화학 고정액이나 냉동절편 법에 의하여 제작된 것 보다 우수하였다.

  • PDF

The Study for the Characteristics of Microwave Coupled $V_2$$O_5$-PbO-$TeO_2$Glass System (마이크로파 발열된 $V_2$$O_5$-PbO-$TeO_2$ 유리의 특성에 관한 연구)

  • 박희찬;이상은;김병우;박성수
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.438-445
    • /
    • 2001
  • 600 W의 마이크로파 출력 하에서 PbO, V$_2$O$_{5}$, TeO$_2$ 및 V$_2$O$_{5}$-PbO-TeO$_2$성분들의 마이크로파 발열 특성을 조사하였다. V$_2$O$_{5}$ 성분의 높은 마이크로파 흡수능에 기인하여 V$_2$O$_{5}$-PbO-TeO$_2$유리상 시편들은 마이크로파를 흡수하여 주어진 온도까지 직접 가열되었다. XRD, OM, SEM 및 고전압 발생 측정기를 통하여 재래식 열 및 마이크로파 공정에서 열처리된 시편들의 결정화 및 전기 전도도의 특성을 비교 조사하였다. PbV$_2$O$_{6}$ 및 Pb$_4$V$_2$O$_{9}$ 결정상들이 마이크로파 열처리된 시편에서는 존재하였다. 그러나, 재래식 열처리된 시편들에서는 존재하지 않는다는 것을 확인하였고, 재래식 열처리된 시편들에 비하여 마이크로파 열처리된 시편들의 전기 전도도 값이 상대적으로 높았다.

  • PDF

Response Characteristics of the Scattered Signal of a Microwave Reflectometry (마이크로파 Reflectometry의 산란 신호 응답 특성)

  • Baang, Sung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.556-561
    • /
    • 2008
  • The characteristics of microwave reflectometry, which is based on the technologies of FM radar and is applied as a non-invasive method to examine the properties including density distribution of inhomogeneous media, is investigated. The microwave reflectometry system requires not only an optimized system hardware but as well as the understanding of system response from the media under test in order to provide the system solution describing the object under test quantitatively. The introduction of microwave reflectometry especially in the area of applied plasma physics has been relatively new and the number of usage is found to be increasing gradually. The experimental method to characterize the microwave system as a device to examine the properties of plasma is explained. The microwave reflectometry signals consist of the cutoff signals which originate from the region where most of the reflected power comes from and the scattered signals which result as an interaction of the microwave and the density perturbations. This paper describes the experimental results of the scattered signal from the microwave reflectometry, such as the wavenumber dependence and the sensitivity on density perturbation, and the comparison of the characteristics with those from the numerical simulations and those from the cutoff signals.

마이크로파 에너지를 이용한 톨루엔 흡착-냉각 응축에 관한 연구

  • Do, Sang-Hyeon;Kim, Seong-Uk;Kim, Yun-Gap;Choe, Seong-U
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.124-126
    • /
    • 2006
  • 마이크로파 에너지의 열원을 이용하여 흡착된 톨루엔을 탈착함으로써 활성탄의 재생에 관한 실험을 실시하였다. 마이크로파를 조사함에 따라 흡착제의 온도가 급격히 상승하여 톨루엔이 탈착할수 있는 온도까지 빠른 시간에 도달하였으며, 이 열에 의하여 톨루엔이 탈착함을 알수 있었다.

  • PDF

Demulsification of Oil-Water Emulsions Using Different Microwave Irradiation Mode (마이크로파 조사 방식에 의한 Oil-Water 에멀젼 분리)

  • Hong, Joo-Hee;Kim, Byoung-Sik;Kim, Dok-Chan
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.653-659
    • /
    • 2005
  • When emulsion is irradiated by a microwave, the energy absorbed by the emulsion is proportional to irradiation time. In case of a long exposure, the temperature of emulsion rises, its viscosity decrease, and subsequently increase the rate of demulsification. In this work, in order to improve demulsification rate, the studies on demusification and the Sauter mean diameter ($D_{32}$) for each microwaved emulsion with different irradiation mode(continuous, pulsative, and periodical irradiation) have been carried out. When the 30% W/O emulsion (sample #1) was irradiated for 600 sec and settled for 24 h, oil recovery rates from continuous, pulsative, and periodical microwave irradiation were 60.0%, 62.3%, and 96.2%, and the amounts of separated water were 26.5%, 35.0%, and 93.9%, respectively. Also, the Sauter mean diameters ($D_{32}$) were $47.183{\mu}m$, $111.547{\mu}m$, and $220.476{\mu}m$, respectively.

ELF and microwave radiation from microwave ovens (전자레인지의 60Hz전자계 및 마이크로화의 방출량 조사)

  • Ji, Hyo-Chul;Kim, Sung-Woo;Lee, Ju-Hyung;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.465-466
    • /
    • 2007
  • 우리가 일상 생환에서 사용하고 있는 전자레인지는 마이크로파를 방출하는 마그네트론이 동작을 하기 위해 예열이 되어야하기 때문에 전력이 항상 공급되고 있다. 따라서 항상 전자기장이 형성되어 있으나 이에 대해서 잘 알지 못한다. 또한 동작 시에 방출되는 마이크로파의 세기가 얼마나 되는지에 대해서도 잘 알지 못한다. 본 논문에서는 100대의 전자레인지에서 0cm, 30cm, 50cm, 100cm 떨어진 거리에서 전원이 On 되었을 때와 Off 되었을 때 자기장을 측정하였으며, 마이크로파는 전자레인지의 동작중 전자레인지에 밀착해서 측정하였다. 이번 조사를 통해 전자레인지에서 측정된 전자기장 및 마이크로파 세기는 모두 ICNIRP 및 정보통신부 인체보호기준 권고안 기준치 이하였고, 마이크로파의 세기는 FDA 규제값 이하였음을 알았다. 측정된 값들은 모두 매우 미약하였다. 그러나 전자기장에 장시간 노출될 경우 인체에 어떠한 영향을 미치는지는 아직 정확히 규명되지 않았기 때문에 전자레인지를 평소의 동선과 멀리 떨어진 곳에 위치시키고 만약의 마이크로파 노출에 대비해 전자레인지가 동작할 때에는 일정거리를 유지하는 것이 좋다.

  • PDF

The Characteristics of TPH Removals by Microwave Radiation for Diesel Contaminated Soil (디젤오염토양 마이크로파 처리 시 TPH의 제거 특성)

  • Jeong, Seung-Woo;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.776-780
    • /
    • 2013
  • TPH degrdation patterns in diesel contaminated soil was investigated with microwave radiation. When microwave radiation on the soil was applied, temperature increment of the aridic soil was quite low, but temperature in the moist soil was dramatically increased even if short period of running time. Up to 20% of the moisture content, the higher moisture content has more increment of temperature, whereas over 20% of the moisture content, temperature in the soil was rather decreased. when 100~700 W power of microwave radiation was applied into the contaminated soil, a lot of TPH removals was observed under 300 W, but negligible increment of TPH removal was detected over 300 W. 60% of TPH removal was achieved with initial 20% moisture content and microwave radiation. Additional 25% removal was accomplished when moisture content was kept constant during radiation period. It indicated that maintaining of constant moisture is an important factor for TPH removal with microwave radiation because moisture and temperature in the soil are decreased with reaction time.

A Study on the Water Sterilizer using the Microwave (마이크로파를 이용한 물 살균장치에 관한 연구)

  • Lee Chang-Ho;Lee Hwa-Yong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.168-171
    • /
    • 2004
  • 본 논문은 마이크로파를 이용하여 물 살균특성을 실험 조사하기 위해 마이크로파 살균장치를 설계 제작하고, 특성을 실험한 결과 매우 양호한 효과를 얻었다. 특히 세균 함유량이 많은 하천수를 마이크로파로 10초, 20초, 30초, 40초, 50초, 60초 살균시켜 수질 검사기관에 수차례 검사를 의뢰한 결과 살균한 물의 대장균수와 일반 세균수가 살균시간에 따라 급격히 감소하는 것을 알 수 있었다.

  • PDF

Synthesis and Study of Pt/MWCNTs Catalysts by Using Microwave Assisted Polyol Method for PEM Fuel Cells (마이크로파-폴리올법을 이용한 고분자 전해질 연료전지용 Pt/MWCNTs 촉매의 제조 및 이의 특성분석)

  • Lee, Tae Kyu;Hur, Seung Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.264-269
    • /
    • 2012
  • In this study, highly loaded(50 wt%) and very stable Pt/MWCNT catalysts for Polymer Electrolyte Membrane Fuel Cells(PEMFCs) are synthesized in short time scale by microwave assisted polyol method with different microwave irradiation time. The XRD and TEM results show that the Pt size becomes bigger as the microwave irradiation time increases. The mean Pt sizes of fabricated catalysts are 4.1, 4.9 and 8.5 nm when the microwave are irradiated for 10, 20 and 30 min, respectively. When compared with Pt catalyst made by conventional polyol method, it shows better long term durability due to the better Pt dispersion on the MWCNT surface.