• Title/Summary/Keyword: 마이크로인젝션

Search Result 5, Processing Time 0.024 seconds

A Study on Injection Attacks and Defenses on Microsoft Windows (MS Windows에서 인젝션 공격 및 방어 기법 연구)

  • Seong, HoJun;Cho, ChangYeon;Lee, HoWoong;Cho, Seong-Je
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.2
    • /
    • pp.9-23
    • /
    • 2020
  • Microsoft's Windows system is widely used as an operating system for the desktops and enterprise servers of companies or organizations, and is a major target of cyber attacks. Microsoft provides various protection technologies and strives for defending the attacks through periodic security patches, however the threats such as DLL injection and process injection still exist. In this paper, we analyze 12 types of injection techniques in Microsoft Windows, and perform injection attack experiments on four application programs. Through the results of the experiments, we identify the risk of injection techniques, and verify the effectiveness of the mitigation technology for defending injection attacks provided by Microsoft. As a result of the experiments, we have found that the current applications are vulnerable to several injection techniques. Finally, we have presented the mitigation techniques for these injection attacks and analyzed their effectiveness.

Micro Robotic Suspended Cell Injection System for Automatic Batch Bio-manipulation (통합 자동화 세포 조작을 위한 마이크로 로보틱 서스펜디드 셀 연젝션 시스템)

  • Kim, Seung-Min;Huang, Haibo;Nahm, Yoon-Eui
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.77-85
    • /
    • 2008
  • 생물학적인 셀 인젝션 기술은 유전자 주입, 시험관 배양, 인공수정 및 신약개발 분야에서 광범위하게 사용되어 오고 있는 기술이다. 생물공학에서 다루는 셀 인젝션 기술은 크게 착생세포 인젝션과 서스펜디드 셀 인젝션으로 구분할 수 있다. 최근 상용화 장비로 출시되고 있는 것들은 착생세포에 대한 자동 인젝션 시스템이 대부분을 차지하고 있다. 반면, 서스펜디드 셀 인젝션 시스템의 경우는 비교적 최근들어 자동화 장비 및 방법론의 개발에 대한 논의가 이루어지고 있는 실정으로 실제 수많은 연구자들의 노력에 힘입어 서스펜디드 셀을 대상으로 한 통합 자동화 셀 인젝션 시스템의 개발이 가속화되고 있기는 하지만 이에 대한 만족할 만한 성과는 아직 이루어 지지 않고 있는 실정이다. 본 논문은 서스펜디드 셀을 대상으로 한 인젝션 시스템 개발에 관한 것으로 특히 셀 홀딩 시스템과 최적의 인젝션 피펫 궤적을 결정하기 위한 시스템 개발에 관한 것이다. 본 논문에서 다루어지는 서스펜디드 셀은 통합 자동화를 위하여 특별히 고안된 셀홀딩 시스템에 의하여 배열의 형태로 고정되며, 셀 인젝션 시스템은 엠브리오와 인젝션 피켓을 이미지 프로세싱 기술에 의하여 인식하고 피펫의 인젝션 궤적을 결정하는 것을 포함하고 있다.

Improvement of Silkworm Egg Microinjection Using 3D Printing Technology (3D 프린팅 기술을 이용한 누에 알 미세주입 기술 개선)

  • Jeong, Chan Young;Lee, Chang Hoon;Seok, Young-Seek;Yong, Sang Yeop;Kim, Seong-Wan;Kim, Kee Young;Park, Jong Woo
    • Korean journal of applied entomology
    • /
    • v.61 no.1
    • /
    • pp.249-254
    • /
    • 2022
  • Silkworms, which have for long been used as an insect resource for industrialization, have recently attracted attention as potential bio-factories for the production of novel biomaterials. In this regard, material production is typically achieved based on transformation technology, mediated via microinjection, in which a target gene is inserted into eggs containing an embryo. However, an essential step in the microinjection procedure is egg fixation, which can be a time-consuming and laborious task. Therefore, in this study, using the 3DCADian program, we adopted a 3D printing approach to model egg liners and glue drawers, which can contribute to facilitating egg alignment and fixation, thereby enhancing transformation efficiency by reducing time consumption and fatigue. After rendering using Fusion 360, the two supplementary tools were produced by printing with nylon resin (PA12) and Sinterit Lisa Pro. Subsequent analysis of the time required to fix eggs on glass slides using the two manufactured tools, revealed that the processing time was reduced by approximately 18.6% when the two tools were used compared with when these tools were not used. These innovations not only reduced fatigue but also contributed to more effective use of the microscope and manipulator for microinjection. Consequently, we believe that with additional research and refinement, the egg liner and glue drawer developed in this study could be used to enhance silkworm transformation efficiency and study similar transformation systems in other industrial insects.

Experiments of Micro Jet Injection for Bio-Medical Application (바이오 분야 적용을 위한 마이크로 젯 인젝션 실험)

  • Ham, Young-Bog;An, Byeung-Cheol;Trimzi, Mojiz Abbas;Kim, Jong-Dae;Lee, Gi-Tae;park, Jung-Ho;Yun, So-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.681-687
    • /
    • 2016
  • It is essential for micro jet injectors in the biomedical sector to operate under high pressure. High pressure injection, however, is accompanied by high volumes. On/Off valves that can be operated at high speeds have been used to address this problem. In this research, piezoelectric actuators which have a response frequency of the order of hundreds of kilohertz were used as the On/Off valve and experiments were applied. Researchers developed a controller to precisely manipulate the piezoelectric valve with various waveforms. They also fabricated five types of nozzles to consider the effect of nozzle type on injection. This allowed researchers to manipulate and confirm factors that can affect the injection volume and force. Results of this experiment have shown how to decrease the injection volume and increase the injection force. and it is predicted that the optimized injection volume and force value can be determined depending on the skin type.

Micro Structure Fabrication Using Injection Molding Method (인젝션 몰딩 기술을 이용한 마이크로 구조물 성형)

  • Je T. J.;Shin B. S.;Chung S. W.;Cho J. W.;Park S. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.253-259
    • /
    • 2002
  • Micro cell structures with high aspect ratio were fabricated by injection molding method. The mold inserts had dimension $1.9cm\times8.3cm$ composed of a lot of micro posts and were fabricated by LIGA process. The size of the micro posts was $157{\mu}m\times157{\mu}m\times500{\mu}m$ and the gaps between two adjacent posts were $50{\mu}m$. Using Polymethylmethacrylate (PMMA) injection molding was performed. The key experimental variables were temperature, pressure, and time. By controlling these, good shaped mim cell structures with $50{\mu}m$ in wall thickness and $500{\mu}m$ in depth were obtained. In order to understand micro molding mechanism, shape changes of molded PMMA were studied with experimental variables. And the durability of mold insert was investigated, too. The results show that the most important factor in molding processes was the mold temperature that is closely related to the filling of the melt into the micro cavity. And the holding time before cooling showed a great effect on the quality of molded PMMA.

  • PDF