• 제목/요약/키워드: 루버

검색결과 54건 처리시간 0.023초

극지운항 선박용 루버 환기창 유동해석에 관한 연구 (A Study on the Flow Analysis of Ventilation Louver for Polar Ship)

  • 이중섭;진도훈
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.16-22
    • /
    • 2018
  • This study is about flow distribution in ventilation systems used in marine louvers. The flow analysis on a louver installed on the vent of a vessel results in the following conclusions: (a) as the velocity of the fluid entering the louver increases, the pressure drop increases; (b) as the pressure drop increases, it tends to increase following a quadratic function. The velocity was confirmed to decrease at the entrance of the louver. This indicates that as the pressure increases, the velocity decreases, and the velocity of the moving fluid is increasing as it passes through the louver vanes.

복합 전열 촉진 핀이 적용된 핀-관 열교환기의 성능에 대한 실험적 연구 (An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4364-4374
    • /
    • 2015
  • 본 연구에서는 복합 전열 촉진 핀 열교환기의 열전달 및 압력손실에 대하여 실험적으로 검토하였다. 비교를 위하여 널리 사용되는 루버 핀 열교환기에 대한 실험도 수행하였다. 핀 피치(1.5mm~1.7mm)와 열수(1열~3열)를 변화시키며 열전달 및 압력손실에 미치는 영향을 검토하였다. 실험범위에서 핀 피치가 j와 f 인자에 미치는 영향은 크지 않았다. 열수가 증가하면 j 인자는 감소하고 f 인자는 열수와 무관하였다. 루버 핀의 j와 f 인자가 복합 전열 촉진 핀의 값들보다 크게 나타났다. 1열의 경우 평균 j 인자와 f 인자는 23%, 27% 크고, 2열에서는 11%, 8%, 3열에서는 10%, 9% 크게 나타났다. 하지만 동일 압력 손실 대비 전열 성능은 복합 전열 촉진 핀 열교환기가 1열에서 6.4%, 2열에서 11.1%, 3열에서 13.6% 크게 나타났다. 기존 루버 핀 상관식은 j 인자를 과대 예측하고 f 인자를 과소 예측하였다.

복합 전열 촉진 핀이 적용된 핀-관 열교환기의 습표면 성능에 대한 실험적 연구 (An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins Under Wet Condition)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5778-5788
    • /
    • 2015
  • 본 연구에서는 복합 전열 촉진 핀 열교환기의 습표면 열전달 및 압력손실에 대하여 실험적으로 검토하였다. 비교를 위하여 널리 사용되는 루버 핀 열교환기에 대한 실험도 수행하였다. 핀 핏치(1.5mm~1.7mm)와 열수(1열~3열)를 변화시키며 열전달 및 압력손실에 미치는 영향을 검토하였다. 실험범위에서 핀 핏치가 j와 f 인자에 미치는 영향은 크지 않았다. 열수가 증가하면 j와 f 인자 모두 감소하였다. 복합 전열 핀 열교환기의 j와 f 인자가 루버 핀 열교환기의 값들보다 크게 나타났다. 1열의 경우 평균 j 인자와 f 인자는 11%, 43% 크고, 2열에서는 8%, 50%, 3열에서는 17%, 53% 크게 나타났다. 동일 압력 손실 대비 전열 성능은 복합 전열 촉진 핀 열교환기가 1열에서 2.0%, 2열에서 3.1%, 3열에서 8.4% 크게 나타났다. 실험 자료를 기존 루버 핀 상관식과 비교하였다.

광폭 루버 핀이 장착된 핀-관 열교환기의 공기측 전열 성능에 관한 실험적 연구 (An Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fin)

  • 김내현
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.254-262
    • /
    • 2015
  • Heat transfer rate can be increased by increasing the heat transfer area. In this study, wide louver fin-and-tube heat exchangers with $P_t/P_l=1.03$ were tested and compared with louver fin-and-tube heat exchanger with $P_t/P_l=0.6$. Results show that heat transfer capacities of wide louver samples are larger (9.8% at one row, 13.6% at two row and 4.1% at three row) than those of conventional louver samples. Considering the area ratio of 1.78, the increase of heat transfer capacity is rather small, possibly due to the smaller heat transfer coefficient and fin efficiency of the wide louver sample. The j factor of the louver fin was 67% larger at one row, 42% larger at two row and 52% larger at three row. The f factor of the louver fin was 81% larger at one row, 63% larger at two row and 60% larger at three row. The effect of fin pitch on j and f factors are not pronounced and the j factor decreased as the number of tube row increased.

루버를 이용한 대형공장 내부 자 연환기유동 개선에 관한 연구 (Improvement for Natural Ventilation Flow inside a Large Factory Building Using Louver-t ype Ventilator)

  • 강종훈;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.705-706
    • /
    • 2008
  • When heat generated inside a large factory building is not discharged due to a stagnant flow, the working environment of workers becomes worse and the cooling of high-temperature products such as hot-rolling coils is delayed. To investigate the natural ventilation inside a large factory building, experimental studies were carried out using wind-tunnel tests. The scale-down factory building models were placed in an atmospheric boundary layer (ABL) and the mean and fluctuating velocity fields were measured using a particle image velocimetry (PIV) technique. For the prototype factory model, the outdoor air is only entrained into the factory building through the one-third open windward wall, and stagnant flow is formed in the rear part of the target area. In order to improve the indoor ventilation environment of the factory building, three different louver-type ventilators were attached at the upper one-third open windward wall of the factory model. Among the three louver ventilators tested in this study, the ventilator model #3 with the outer louver (${\theta}_o$ = 90$^{\circ}$) and the inner louver (${\theta}_i$ = -70$^{\circ}$) was found to improve the natural ventilation inside the factory building model effectively. The flow rate of the entrained air was increased with aligning the outer louver blades with the oncoming wind and guiding the entrained air down to the ground surface with elongated inner louver blades.

  • PDF

사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구 (Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser)

  • 장헌덕;이대희;이진호
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.683-687
    • /
    • 2012
  • 본 연구는 CFD 해석을 이용하여 사각 천장형 루버 디퓨저의 토출각도와 토출 유량에 따른 실내 공기유동 특성에 관한 것이다. CFD 툴은 상용프로그램인 ANSYS 13.0의 CFX를 이용하였다. 연구에 사용된 디퓨저는 적은 유량에서도 충분한 도달거리를 확보할 수 있도록 모델링하였으며, 실내 크기는 $6{\times}6{\times}2.7m$로 디퓨저의 대각선 방향으로 원형 배기구를 모델링 하였다. 토출 공기의 체적유량은 5.1CMM, 7.4CMM이며, 디퓨저의 토출각도를 $30^{\circ}$에서부터 $60^{\circ}$까지 $10^{\circ}$씩 변화하여 실내의 유동특성에 대하여 고찰하였다.

개량 루버핀에 의한 열전달 성능향상에 관한 연구 (Numerical Analysis on the Heat Transfer Enhancement by Modified Lovour Fin)

  • 정재동;박병규;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.408-413
    • /
    • 2001
  • Numerical analysis on the three-dimensional laminar flows (Re=1000) and heat transfer in a rectangular channel with punched longitudinal vortex generator have been conducted to explore the heat transfer enhancement and the combined effect of the angle of attack ${\alpha}$ and the lovour angle ${\beta}$. Rectangular winglets have been used as vortex generators. Velocity and temperature fields and spanwise averaged Nu and friction factor were presented. Enhancement of heat transfer and flow loss penalty are evidenced. The results show performance characteristics allowing a reduction in heat transfer surface area of 62% for fixed heat duty and for fixed pumping power compared with that of channel flow without vortex generator. However, adding lovour angle to the vortex generator shows no positive effect on the heat transfer enhancement.

  • PDF

PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구 (Improvement of Natural Ventilation in a Factory Building Using PIV Technique)

  • 강종훈;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF

아이스 클래스(Ice-Class)루버의 기술개발 동향 (Technique Development Tendency for Ice Class Louver)

  • 서광옥;심의보;노병수;조대환
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2015년도 춘계학술대회
    • /
    • pp.41-42
    • /
    • 2015
  • 극해 지역은 채굴가능 매장량의 30% 정도의 각종 천연자원이 매장되어 있으며 기후변화로 인해 북극해 항로를 이용한 운항 및 자원의 수송과 저장을 위해 빙해 선박과 극지용 해양구조물의 수요가 증가하고 있다. 이 연구에서는 아이스 클라스 등 방한기술에 근거하여 빙해 선박에 탑재되는 루버의 기술개발 동향에 대해 고찰 하였다.