• Title/Summary/Keyword: 로고스키 원리

Search Result 3, Processing Time 0.021 seconds

A Study about the Application of Rogowski Coil on the LTCC (LTCC기판상에 구현한 로고스키코일의 적용에 관한 연구)

  • Kim, Eun-Sup;Son, Won-Keun;Moon, Hyung-Shin;Park, Sung-Hyun;Shin, Byung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.28-28
    • /
    • 2008
  • Generally speaking, Rogowskii coil for magnetic flux change detection according to electric current is used for digital addition watt-hour meter, because it is not saturated at electromagnetic that not Current Transformer working by magnetic material but non-magnetic material. In this paper, we described sensitive quality an electric current coil sensor followed by the principal of Rogowskii coil on the low dielectric loss LTCC, change different line width, gap, line length at sensing parts and extinction parts.

  • PDF

Development of Current and Voltage Sensors for Distribution switchgears (로고스키 코일과 저항 분압기 원리를 이용한 배전급 전류/전압 센서 개발)

  • Choe, W.J.;Sohn, J.M.;Lee, B.W.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.888-890
    • /
    • 2003
  • In the distribution networks, it is required to develop compact and smart current and voltage sensors for compact and digital switchgears. The sensor developed newly adopt the priciple of rogowski coil for current sensing and resistive voltage divider for voltage sensing. The sensing characteristics and reliabilities were improved compared to conventional ones. In the near future, these voltage and current sensing apparatus will be widely used with electronic protection units for the distribution switchgear.

  • PDF

AC Current Sensor Using Air Core (공심코어를 사용한 교류전류 센서)

  • Park, Young-Tae;Jung, Jae-Kap
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • This paper describes a current sensor for precision current measurement of an electronic watt-hour meter that is going to install in houses in the future. As the current sensor is based on an cored principle (the Rogowski principle) it is not subject to usual limitations of saturation and non-linearity of general current transformers. An advantage of the developed current sensor is that non-linearity error in low current range is improved and the construction can be kept simple using an air core. We present a magnetic field analysis of the sensor using a finite-element solver. We compared the measured values versus the calculated values.