• Title/Summary/Keyword: 레진 접착제

Search Result 215, Processing Time 0.034 seconds

A Change of Shear Bond Strength of Orthodontic Resin Adhesives under Water Immersion (침수후 시간에 따른 교정용 레진접착제의 전단결합강도 변화)

  • Lee, Je-Jun;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.783-789
    • /
    • 1998
  • The purpose of this study was to evaluate the changes of shear bond strengths and failure patterns in orthodontic resin adhesives according to the water immersion time. Metal brackets were bonded to the specimens involving the premolars with chemical-cured($Concise^{\circledR}$) and light-cured($Transbond^{\circledR}$) adhesives. The shear bond strength was measured on universal testing machine and the failure patterns were assessed with the adhesive remnant index(ARI) after storage in distilled water at $37^{\circ}C$ for 1 day, 1 week and 1, 3, and 6 months, respectively. The results were as follows. 1. The shear bond strengths at the 6 month in both Concise and Transbond were significantly higher than those at the 1 day, 1 week and 1 month(p<0.05). There were positive correlations between shear bond strength and water immersion time in both Concise and Transbond(P<0.01). 2. There were no significant differences in shear bond strength between Concise and Transbond. 3. The brackets were failed primarily at the bracket base-adhesive interface and there was no significant difference in the incidence of ARI scores according to the water immersion time.

  • PDF

THE EFFECT OF LIGHT CURING METHODS AND RESIN ADHESIVES ON THE MICROLEAKAGE OF RESTORATIONS IN PRIMARY TEETH (광중합 방법 및 레진 접착제의 종류에 따른 유치 수복물의 미세누출)

  • Jeong, Young-Nam;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.592-599
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the effects of several light curing methods and several adhesives on the microleakage of composite resin restorations in primary teeth. Materials and methods : In 150 extracted human primary anterior teeth, O-shaped cavities were prepared in the labial surface ; the cavity diameter and depth were 1.6mm. The cavities were filled with light-activated composite resin, Compoglass. Four kinds of adhesives were used. Each filling materials were polymerized with three light cure methods. The restorations were polished using Sof-Lex discs(3M Co., USA). The samples were thermocycled 1,000 times between $5^{\circ}C$ and $55^{\circ}C$ with a 1-minute dwell time. Then, they were immersed in a 2% methylene blue solution(pH 7) for 12hours. Subsequently they were sectioned labio-lingually through the center of the restoration with a diamond saw at low speed with a water coolant, and evaluated by stereomicroscopy. Microleakage analyses were done, using scores from 0 to 4. Results : Results showed the least microleakage in Compoglass group(P<0.05). There were less microleakage in SBMP group among the adhesive groups, but no significant difference was observed(P>0.05). And there were no significant differences among the groups depending on curing methods(P>0.05).

  • PDF

SPRC 강판의 표면전처리 공정에 따른 에폭시 접착부 특성 평가

  • Kim, Hae-Yeon;Kim, Min-Su;Kim, Jong-Hun;Kim, Mok-Sun;Kim, Jun-Gi
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.56.2-56.2
    • /
    • 2011
  • 최근 철강, 알루미늄, 이종재료의 접합 등 용접이 어려운 부분에 구조용 접착제의 적용이 증가하고 있는 추세이다. 이를 위해 변성 에폭시레진을 활용한 고접합 강도, 고인성의 구조용 접착제가 연구되어 지고 있다. 피착제의 표면처리는 접합부의 접합강도를 향상시키는 방법으로 알려져 있으나 최근의 구조용 접착제는 표면 전처리 없이도 우수한 접착 특성을 보이는 것으로 기대되고 있다. 본 연구에서는 변성레진에 대해서 각종 표면처리가 접합부 특성에 미치는 영향을 조사하였다. 피착제로는 자동차용 냉연강판인 SPRC440을 사용하였고, 전처리로는 무처리 상태, SiC연마지를 이용한 연마, 아르곤 및 산소가스를 이용한 마이크로웨이브 플라즈마 표면처리, 산세 등의 표면처리를 실시하였다. 에폭시 접착제는 변성 에폭시 레진과 경화제 및 촉매제를 이용하여 직접 포뮬레이션하였다. 단일 겹치기 전단강도 시험과 T-Peel 시험은 각각 ASTM D 1002 규격에 따라 준비하였으며 인장 시험 후 파면은 SEM으로 관찰하였다.

  • PDF

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.

COMPARATIVE BOND STRENGTH OF SINGLE STEP ADHESIVES TO DIFFERENT DENTINAL DEPTHS (상아질의 깊이에 따른 단일 단계 접착제의 결합강도 비교)

  • Cho, Young-Gon;Jin, Cheol-Hee;Min, Jung-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.319-326
    • /
    • 2005
  • This study compared the microtensile bond strength $({\mu}TBS)$ of single step adhesives to different dentin depths. Superficial or deep dentin was exposed in 30 molar teeth by sectioning immediately under the DEJ or 1.5mm area from central pit, respectively. After polishing with 600-grit SiC paper, the dentin surfaces were assigned to three groups: AQ group-AQ Bond, L-Pop group-Adper Prompt L-Pop, Xeno group-Xeno III. The bonded specimens were sectioned into sticks and subjected to ${\mu}TBS$ testing with a crosshead speed of 1mm/minute. The results of this study were as follows; The ${\mu}TBS$ to superficial dentin was higher than that to deep dentin in all group. The ${\mu}TBS$ of Xeno group was significantly higher than that of L-Pop group and AQ group in both superficial and deep dentin (p<0.05).

Evaluation of Microleakage and Penetration Ability of Flowable Resin in Occlusal Fissure (유동성 레진의 교합면 열구내 침투도와 미세누출 평가)

  • Cheong, Hyeran;Im, Sungok;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.89-98
    • /
    • 2017
  • The aim of this study was to compared the penetration scores and microleakage levels of flowable resin in comparison to resin-based pit and fissure sealant. A total 120 extracted premolars were used and classified with group I (resin-based pit and fissure sealant), group II (flowable resin), group III (bonding agent + flowable resin), IV (fissurotomy + bonding agent + flowable resin) depending on the materials and the application methods. The penetration scores of the group treated with flowable resin following fissurotomy were similar to those of the group treated with resin-based sealant, but higher compared to those of the other groups treated with flowable resin without fissurotomy or bonding agent. The group treated with flowable resin following fissurotomy also exhibited the lowest microleakage levels. The group treated with resin-based sealant and the one treated with a bonding agent prior to the application of flowable resin showed similar microleakage levels. In conclusion, flowable resin may be applied as a pit and fissure sealant, and its application along with fissurotomy could increase the penetration scores.

RESIN TAG FORMATION OF SELF-ETCHING ADHESIVES (자가부식 접착제의 레진 Tag 형성)

  • Kim, Young-Jae;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.143-152
    • /
    • 2003
  • The aims of the present study was to observe resin tag of the resin/enamel, dentin interface produced by self-etching adhesive systems and evaluate effect of additional acid etching on resin tag formation. Three self-etching primer(SE bond, AQ bond and L Pop) and an one bottle adhesive(Single bond) were used. Flat occlusal enamel and dentin disks were obtained from extracted human molars. A total of 20 surfaces were collected and divided into four groups of 5 samples. One-half of each specimen in each group was etched with 35% phosphoric acid prior to the application of each adhesive system, with the second half being kept unetched. Subsequently, resin composite was placed and polymerized. The samples were sliced and immersed into HCl and NaOCl solutions, followed by drying and sputter coating for examination with a SEM. The results were as follows; 1. Additional etching side of dentin displayed longer and thicker resin tag than unetched side in all self-etching adhesive groups. 2. In enamel, additional etching side displayed deeper and more distinct etching pattern than unetched side except L Pop. There is no difference between etched and unetched enamel in L Pop. The results obtained suggest the self-etching adhesive did not etch enamel and penetrate into dentinal tubule as deeply as did additional etching. Further research should include the evaluation of the relationship of boding strength, microleakage and resin tag morphology.

  • PDF

COMPATIBILITY OF SELF-ETCHING DENTIN ADHESIVES WITH RESIN LUTING CEMENTS (자가부식형 상아질접착제와 레진시멘트와의 적합성에 관한 연구)

  • Kim, Do-Wan;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.493-504
    • /
    • 2005
  • This study was performed to investigate the compatibility between 4 dentin adhesives and 4 resin luting cements. Dentin adhesives used in this study were All-Bond 2 (Bisco Inc., Schaumbrug, IL, USA), Clearfil SE-Bond (Kuraray Medical Inc, Osaka, Japan), Prompt L-Pop (3M Dental Products, St. Paul, MN, USA), One-Up Bond F (Tokuyama corp., Tokyo, Japan) Resin luting cements used in this study were Choice (Bisco Inc., Schaumbrug, IL, USA), Panavia F (Kuraray Medical Inc, Osaka, Japan), RelyX ARC (3M Dental Products, St. Paul, MN, USA) Bistite II DC (Tokuyama corp., Tokyo, Japan). Combination of each dentin adhesive and corresponding resin cement was made to 16 experimental groups. Flat dentin surfaces was created on mid-coronal dentin of extracted mandibular third molars, then dentin surface was polished with 320-grit silicon carbide abrasive papers. Indirect resin composite block (Tescera, Bisco) was fabricated. Its surface for bonding to tooth was polished with silicon carbide abrasive papers Each dentin adhesive was treated on tooth surface and resin composite overlay were luted with each resin cement. Each bonded specimen was poured in epoxy resin and sectioned occluso-gingivally into 1.0mm thick slab, then further sectioned into $1.0{\times}1.0mm^2$ composite-dentin beams. Microtensile bond strength was tested at a crosshead speed of 1.0mm/min. The data were analysed by one-way ANOVA and Duncan's multiple comparison tests The results of this study were as follows, 2-step self-etching dentin adhesive which has additional bonding resin is more comparison than tests. self-etching dentin adhesive.

The effect of cavity configuration on the mechanical properties of resin composites (중합환경에 따른 복합레진의 물리적 성질에 관한 연구)

  • Ryu, Gil-Joo;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.239-248
    • /
    • 2002
  • 이 연구의 목적은 와동의 형태가 굴곡강도와 탄성계수 등 복합레진의 물리적 성질에 미치는 영향을 평가하는 것이다. 복합레진은 Clearfil$^{TM}$ AP-X(Kuraray, Japan)와 Esthet-X$^{TM}$(Dentsply, USA)가 이용되었으며, 상아질 접착제는 Clearfil$^{TM}$ SE Bond(Kuraray, Japan)와 Prime & Bond NT$^{TM}$(Dentsply, USA)를 사용하였다. 대조군의 시편은 split steel mold(25mm$\times$2mm$\times$2mm) 내에 상기 2종류의 복합레진을 충전하여 2개의 대조군 시편을 제작하였으며, 2.4 및 3.4의 C-factor를 부여하기 위한 유리 모형와동을 제작하고, 와동 내에 상기 2종류의 복합레진을 충전하기 전 유리와동의 내면은 sandblasting 처리하고 각각의 복합레진과 동일회사 제품의 상기 상아질 접착제로 처리한 후, 복합 레진을 각각 충전하여 4개의 실험군을 제작하였다. 제작된 실험군 시편은 저속 diamond saw로 충전된 복합레진 부위의 중심부를 통과하도록 절단하여 레진기둥(25mm$\times$2mm$\times$2mm)이 되도록 제작하였다. 제작된 시편을 37$^{\circ}C$의 증류수에 24시간 동안 보관 후, 만능시험기(EZ Test, Shimadzu, Japan)를 이용하여 분당 1mm의 crosshead speed로 3점 굴곡강도를 측정하였다. 또 Linometer(R&B, Korea)를 이용하여 복합레진의 중합수축량을 측정하였으며 굴곡강도측정 후 시편의 파단면은 주사전자현미경(S-2300, Hitachi, Japan)을 이용하여 관찰하였다. 실험결과의 통계분석은 95% 수준의 one-way ANOVA/Tukey's test를 이용하여 결과를 얻었다. 실험에 이용된 2종류 복합레진의 굴곡강도와 탄성계수는 C-factor치 증가에 따라 감소하였으며, 파단면 또한 C-factor의 증가에 따라 더 불규칙해지는 양상을 나타내었다. 본 실험의 결과 hybrid형 복합레진이 micro-hybrid형 복합레진에 비해 C-factor의 영향을 더 많이 받는 것으로 나타났으며, 와동의 C-factor증가가 굴곡강도나 탄성계수와 같은 복합레진의 물리적 성질을 저하시킨다는 것을 의미하였다.