• 제목/요약/키워드: 레진 접착제

검색결과 215건 처리시간 0.039초

수종의 상아질 접착제와 복합레진의 적합성에 관한 연구 (A STUDY ON THE COMPATIBILITY OF DENTIN ADHESIVES WITH COMPOSITE RESINS)

  • 박진성;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.214-234
    • /
    • 1995
  • The purpose of this work was to study the compatibility of several commercially available dentin adhesives with composite resins. In this study, V-shaped cavity preparations were created on both buccal and lingual surfaces of 60 extracted human premolars($3mm{\times}3mm{\times}2mm$ deep). Preparations were located such that the occlusal margins were on the enamel and the gingival margins were on the cementum(1mm below the CEJ). These specimens were randomly divided into three equal groups. Three dentin adhesives(Scotchbond Multi-Purpose, All Bond 2, Prisma Universal Bond 3)were applied to the cavity in accordance with each manufacturer's instructions. The teeth in each group were restored with four composite resins(Silux plus, Z100, Bisfil, Prisma TPH) in three increments, with each increment light-cured for 40 seconds. All specimens were exposed to 500 cycles of thermal stress. Specimens then placed in a silver nitrate solution(50% by weight) and stored in darkness for 24 hours. They were then immersed for 6 hours in photographic developing solution under flourescent light. Specimens were sectioned buccolingually through the center of the restoration and observed under a binocular stereoscope. To compare the marginal leakage, ANOVA and Dunkan's multiple range tests were used in analysis. Selected samples were further studied using scanning electron microscopy(XL20, Philips, The Netherlands). The results were as follows. 1. In all groups, the enamel margin showed significantly less leakage than the cementum margin. 2. No statistically significant differences were found in microleakage when composite resins were used with their proprietary dentin adhesives. 3. In comparison between dentin adhesives, Prisma Universal Bond 3 showed significantly less leakage at the enamel margin and Scotch bond multi-purpose showed significantly less leakage at the cementum margin than the other groups. 4. In comparison between composite resins, Silux Plus showed significantly more leakage than other groups at the enamel margin and no statistically significant differences were found in microleakage at the cementum margin. 5. According to the backscattered scanning electron microscope, microleakage occurred via gaps at the dentin adhesives/dentin interface.

  • PDF

상아질 접착제의 중합 시간 조절에 따른 복합레진의 중합 수축 방향의 변화 (THE EFFECT OF ADHESIVE CURING TIMING ON THE DIRECTION OF POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN)

  • 배지현;오명환;김창근;손호현;엄정문;조병훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.316-325
    • /
    • 2001
  • The purpose of this study was to evaluate the effect of adhesive curing timing on the direction of polymerization shrinkage of light-curing composite resin. In this study, the curing times of adhesive and composite resin were measured by differential scanning calorimeter(DSC). 28 extracted human molars were embedded in clear resin and box-type cavities were prepared. Based on DSC data, the experimental teeth were divided into 4 groups. Group 1: no bond; Group 2: late curing; Group 3: Intermediate curing; Group 4: Early curing. After treating with adhesive, the buccal cavities were filled with Z-100 hybrid composite resin and the lingual ones were filled with AEliteflo flowable composite resin. The depressions at the surface were measured by surface profilometer, then the specimens were embedded in clear resin and sectioned. Impressions were obtained and used to get epoxy resin replicas. The epoxy replicas were gold-coated and observed under SEM. Average Maximum Gap(AMG), Gap Proportion(GP), Average Marginal Index(AMI) were used to compare the shrinkage gap of each group. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA, Student-Newman-Keuls method. The results of this study were as follows. 1. Average Maximum Gap, Gap Proportion, Average Marginal Index and depression at the surface or Z-100 hybride composite resin were smaller than those of AEliteflo flowable composite resin(P<0.05). 2. When the bonding between composite resin and tooth structure was strong, the shrinkage gap was small, and depression at the surface was deep(P<0.05). 3. In the well-bonded group, light-curing composite resin shrank toward bonded cavity wall, not toward light source. The result suggested that the direction of polymerization shrinkage was affected by the quality of bonding in the dentin-resin interface. The strong was the bonding between composite resin and tooth structure, the smaller was the gap and the deeper was the depression at the surface. Then the flow to compensate the polymerization shrinkage proceeded from surface to bonded cavity wall.

  • PDF

상아질 접착제의 사용에 의한 광중합성 복합레진의 변연접합도에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECTS OF DENTIN ADHESIVES ON MARGINAL ADAPTATION OF LIGHT CURED COMPOSITE RESIN)

  • 박성호;이정석;박동수;이찬영;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.141-152
    • /
    • 1990
  • The purpose of this study was to evaluate the effects of dentin adhesives(Gluma$^{(R)}$ and Scotchbond 2$^{(R)}$) on the marginal adaptation of light cured composite resin (Heliosit$^{(R)}$) by using SEM. The recently extracted 30 teeth were used and round cavities were prepared on the occlusal surfaces of the teeth with predesigned depth and diameter. The teeth were divided into three groups. Group 1 : Gluma$^{(R)}$ + Heliosit$^{(R)}$ Group 2 : Scotchbond 2$^{(R)}$ + Heliosit$^{(R)}$ Group 3 : Enamelbond$^{(R)}$ + Heliosit$^{(R)}$ Filling with Heliosit, the teeth were stored in saline solution for 24 hours. After the thermocycling procedure, the teeth were cut vertically into the restorations. The SEM observation was carried out to evaluate the marginal adaptation of the composite resin. The following results were obtained. The following results were obtained. 1. The groups using Gluma$^{(R)}$ and Scotchbond 2$^{(R)}$ showed better than the control group on marginal adaptation to the dentin. 2. The group using Gluma$^{(R)}$ was superior to the group using Scotchbond 2$^{(R)}$, but the difference was not significant. 3. In all groups, the marginal gaps were wider on the pulpal walls than on the lateral walls of restorations.

  • PDF

교정용 광중합형 및 화학중합형 레진접착제의 전단결합강도와 파절양상에 대한 연구 (A STUDY OF SHEAR BOND STRENGTH AND FAILURE PATTERNS IN LIGHT-AND SELF-CURED ORTHODONTIC RESIN)

  • 이민하;양규호;박영준
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.549-558
    • /
    • 1996
  • Light-cured orthodontic composite resin has been widely advertised recently for use in bonding brackets. However, the curability of light-cured resin when light waves are diffused through metal brackets in questionable. The purposes of this study were to evaluate shear bond strength and failure patterns of visible light-cured resin(Lightbond) and chemically cured-resin(Mono-Lok 2), and to determine the relative value of light-cured resin as an alternative to conventional chemically cured resin. Each of the two resins was tested on twenty extracted human first premolars. Standard edgewise metal brackets were bonded to the teeth in accordance with the manufacturers' recommendation. After bonding, the teeth were stored for 24 hours at $37^{\circ}C$, 100% humidity. The shear bond strength was tested with a universal testing machine(Instron 4302), at 0.5mm/min crosshead speed. After debonding, brackets and enamel surfaces were examined with a scanning electron microscope and a stereoscopic microscope. The results were as follows : 1. Metal brackets bonded with Lightbond showed statistically higher shear bond strength than metal brackets bonded with Mono-Lok2. 2. The predominant failure site in Lightbond was the enamel-resin interface, and in Mono-Lok 2 it was the resin itself. 3. Enamel cracks were not found in any specimen. The above results suggest that direct bonding of metal brackets to enamel with light-cured resin bonding agent can be used effectively in clinics.

  • PDF

상아질 접착제를 사용한 광중합 복합레진과 Glass Ionomer Cement의 전단 결합력에 관한 연구 (AN EXPERIMENTAL STUDY FOR SHEAR BOND STRENGTH OF COMPOISTE RESIN USING SEVERAL DENTIN BONDING AGENTS AND LIGHT CURED GLASS IONOMER CEMENT)

  • 권병렬;이제호;최형준;이종갑
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.450-460
    • /
    • 1996
  • The purpose of this study was to compare shear bond strength of composite resin using several dentin bonding agents and light cured glass ionomer cement(Fuji II LC). 40 Bovine primary anterior teeth were used for this experiment. Labial surface of teeth were flattened. It were divided into four groups. Each group was composed of 10 teeth. The material used for this experiment were Scotchbond Multipurpose-Z-100, Allbond 2-Aelitefil, Gluma-Pekalux, light cured glass ionomer cement(Fuji II LC). Each of the materials was applied to the exposed surfaces of 10 teeth by insertion into a cylindrical shaped matrix which is 3mm diameter and 3mm in height. The completed specimens were stored at $37^{\circ}C$ under 100% humidity for 24 hours : the shear bond strength of each material to dentin surface were measured with INSTRON universal testing machine. The results were as follows : 1. Shear bond strength to dentin surface increased in order of light cured glass ionomer cement(Fuji II LC), Gluma, Allbond 2, Scotchbond Multipurpose. 2. Between shear bond strength of light cured glass ionomer cement(Fuji II LC) and Allbond 2, there was statistical significace(p<0.05) 3. Between shear bond strength of light cured glass ionomer cement(Fuji II LC) and Scotchbond Multipurpose, between shear bond strength of Gluma and Scotchbond Multipurpose, there was statistical significance.(p<0.01) The shear bond strength of dentin bonding agents were higher than light cured glass ionomer cement. The reason is that materials and quality of dentin bonding agent were enhanced. Further investigation is necessary to improve shear bond strength of light cured glass ionomer cement.

  • PDF

단일용기 상아질 접착제 처리 후 레진-상아질 경계면에 대한 투과전자현미경적 연구 (A TEM STUDY OF THE RESIN-DENTIN INTERDIFFUSION ZONE FORMED BY ONE-BOTTLE DENTIN ADHESIVE SYSTEMS)

  • 양동운;박성호;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.180-192
    • /
    • 2000
  • One bottle system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. There has been many studies to measure the bond strength of one bottle systems but no actual work has been done on micromorphologic study of resin-dentin interdiffusion zone after one bottle system application. To evaluate the bonding patterns of various commercially available one bottle systems to dentin, observation of resin-dentin interdiffusion zone under TEM was performed. Caries-free human third molars within one month of extractions were chosen for the experiments. The molars were sectioned 1mm above the cementoenamel junction and got rid of the root portions. Crown portions of the teeth were sectioned parallel to occlusal surface so that dentin discs of 1mm in thickness were remained. 7 one bottle systems and 1 two bottle system were applied according to manufacturer's instructions and followings were the results. 1. In every experimental groups, cross bandings of collagen fiber were distinguishable and tight bon dings between the bonding agents and dentin were observed. 2. Hybrid layer was clearly observed in ONE-STEP$^{(R)}$, Prime & Bond$^{(R)}$ 2.1, Syntac$^{(R)}$ SC, MAC-BOND II groups but it was not clear in Single Bond, D-Liner Dual PLUS, ONE COAT BOND groups. 3. Electron-density of hybrid layer was uniform in pattern in MAC-BOND II, Prime & Bond$^{(R)}$ 2.1 groups but not so uniform in ONE-STEP$^{(R)}$ group. 4. Electron-dense amorphous phase in most superior layer of the resin-dentin interdiffusion zone was characteristically observed in Single Bond, Syntac$^{(R)}$ SC, ONE COAT BOND groups. It can be concluded that bondings between the dentin bonding agents and dentin can be various in pattern according to their chemical compositions and the condition during applications.

  • PDF

글라스 아이오노머 시멘트와 불소함유 레진의 불소유리에 관한 연구 (IN VITRO STUDY ON THE FLUORIDE RELEASE FROM GLASS IONOMER CEMENTS AND A FLUORIDE-CONTAINING RESIN)

  • 김미경;이기수
    • 대한치과교정학회지
    • /
    • 제28권3호
    • /
    • pp.399-407
    • /
    • 1998
  • 불소를 유리하는 치과재료인 글라스 아이오노머 시멘트와 불소함유 레진을 대상으로 경화후의 시간경과에 따른 1일간 불소유리량을 측정하고, 이들의 경시적 변화추세를 비교 검토하기 위하여 광중합형 글라스 아이오노머 시멘트로서 치과교정용 브라켓 접착제($Orthobond^{\circledR}$)와 충전응(Fuji GC $LC^{\circledR}$), 자가중합형 글라스 아이오노머 시멘트로서 충전용 (Fuji GC $II^{\circledR}$)과 아말감 합금이 첨가된 충전용(Miracle-$Mix^{\circledR}$) 및 광중합형 불소함유 충전용 레진($Heliomolar^{\circledR}$)을 실험재료로 하여 중합 1일, 3일, 7일, 14일, 42일, 70일 경과후 각각 불소유리량을 측정하고, 변화추세를 비교 검토하여 다음의 결론을 얻었다. 1. 전 실험기간에 걸쳐 불소함유 레진의 1일간 불소유리량은 글라스 아이포노머 시멘트에 비해 현저히 적었다. 2. 중합 70일 경과후 1일간 불소유리 량은 Miracle-$Mix^{\circledR}$는 평균 $3.4{\mu}g/cm^2$, Fuji GC $II^{\circledR}$가 평균 $2.7{\mu}g/cm^2$, $Orthobond^{\circledR}$가 평균 $2.3{\mu}g/cm^2$, Fuji GC $LC^{\circledR}$이 평균 $1.4{\mu}g/cm^2$였고, 불소함유 레진인 $Heliomolar^{\circledR}$은 평균 $0.1{\mu}g/cm^2$이었다. 3. 1일간 불소유리량은 자가중합형 글라스 아이오노머 시멘트와 광중합형 글라스 아이오노머 시멘트사미에 차이를 발견할 수 없었고, 제조회사의 제품에 따라 유의한 차이가 있었다 아말감 합금이 첨가된 Miracle-$Mix^{\circledR}$은 아말감 합금이 첨가되지 않은 다른 시멘트에 비해 현저히 많은 양의 불소를 유리하였다. 4. 모든 실험재료의 1일간 불소유리 량은 중합 3일이전까지 현저한 감소를 보였고, 중합 3일경과이후 중합 14일 이전까지 완만한 감소를, 중합 14일이후부터 중합 70일경과까지 매우 완만한 감소추세를 보였다.

  • PDF

우치에 대한 All-in-one 상아질 결합제의 전단결합강도 비교 연구 (STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM)

  • 박형주;유승훈;김종수
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.661-672
    • /
    • 2006
  • 우치 60개를 준비하여 법랑질과 상아질에 대하여 각각 1군 AQ Bond, 2군 AQ Bond $Plus^{TM}$, 3군 Single $Bond^{TM}$로 설정하고, 군당 10개씩 배정하였고, 군당 혼화층 관찰에 5개와 resin tag 관찰을 위해 5개씩 배정하였다. 준비된 우치의 법랑질과 상아질을 노출시킨 후 제조사의 지시에 따라 표면을 처리하고, 내경 3mm의 폴리에틸렌 튜브를 이용하여 $Z-250^{TM}$ 복합레진 접착을 시행하였다. 100% 습윤 상태에서 24시간동안 보관 후 $5^{\circ}C$$55^{\circ}C$ 조건하에서 500회 열순환을 시행하였다. 만능시험기를 분당 cross head speed 5mm 속도로 설정하고 100kg F load cell을 사용하여 전단결합강도를 측정하고 파절된 시편들을 수거하여 주사전자현미경으로 파절면을 관찰하였다. 혼화층과 resin tag 관찰을 위하여 상아질 접착면에 대해 수직으로 절단하고 인산과 질산으로 처리한 후 주사전자현미경으로 관찰하였다. 이상의 결과를 토대로 행동 조절에 어려움이 많은 소아 환자의 복합레진 수복시 적용 과정 및 시간 단축이 장점으로 부각되고 있는 all-in-one system의 임상 적용 가능성을 평가하고 다음과 같은 결론을 얻었다. 1. 전단 결합 강도 측정결과 1군, 2군 간에는 유의차가 없었으나, 3군이 1군과 2군에 비해 높은 전단 결합 강도를 보였으며 통계학적 유의차를 보였다 (p<0.05). 2. 파절 양상 관찰 결과 1군과 2군의 법랑질과 상아질 모두에서 그리고 3군의 상아질에서 주로 adhesive fracture 양상을 보였으며, 3군 법랑질에서 각각 cohesive와 adhesive fracture가 균등한 분포를 보였다. 3. 주사 전자 현미경 소견에서 1군과 2군은 resin tag형성이 매우 미약하고 불규칙한 양상을 보인 반면, 3군에서는 비교적 긴밀하게 형성된 resin tag이 관찰되었으며 resin tag의 표면에 형성된 뚜렷한 측부 가지들도 발견되었다.

  • PDF

산 처리가 상아질 접착에 미치는 영향 (EFFECT OF ACID-TREATMENT ON DENTIN BONDING)

  • 김영경;김성교;박진훈
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.73-83
    • /
    • 1993
  • 산 처리방법에 따른 상아질 접착을 평가하고 표면처리 후의 상아질 표면의 성상변화 및 파단면의 양상을 관찰하기 위해 발거된 구치 에 10% polyacrylic acid (GC Dental Industrial Corp., U. S. A.), 10 % 인산(Bisco Inc., U. S. A.) 및 10-3 용액 (Parkell Bio-Materials, U. S. A.)을 사용하여 상아질 표면을 처리하고 모든 시편에 상아질 접착제인 All Bond 2$^{(R)}$(Bisco Inc., U.S.A.)를 도포하였으며 복합레진 (Silux Plus$^{(R)}$, 3M Co., U.S.A.)을 첨가한 후 접착강도를 측정하고 상아질 표면 및 파단면을 주사 전자현미경으로 관찰, 비교하여 다음과 같은 결과를 얻었다. 1. 접착강도는 상아질 표면을 산 처리한 군이 무처리한 대조군에 비해 높게 나타났고, 산처리를 시행한 군들 간에는 10-3 용액으로 처리한 군이 가장 높았으며 10% 인산으로 처리한 군, 10% polyacrylic acid로 처리한 군의 순이었다(p<0.01). 2. 상아질 표면의 관찰에서, 무 처리의 상아질 면은 상아세관이 개방되지 않은 채 도말층으로 덮혀 있었고, 10% polyacrylic acid로 처리한 상아질 면은 도말충이 제거되고 상아세관이 개방되어 있었으나 상아세관 내에 smear plug이 일부 남아 있었으며, 10% 인산또는 10-3 용액으로 처리한 상아질 면은 도말층 및 smear plug이 모두 제거되고 상아세관이 완전히 개방되어 있음이 관찰되었다. 3. 파단면의 관찰에서, 무 처리군에서는 도말층 내에서 파단이 일어났으며, 10% polyacrylic acid로 처리한 군에서는 상아세관 내 잔존 레진 tag이 관찰되지 않았으나 10% 인산 및 10-3 용액으로 처리한 군에서는 상아세관 내의 잔존 레진 tag이 관찰되었다. 4. 파단 양상에 있어서, 접착강도가 큰 군일수록 응집성 파단의 빈도가 증가되어 나타났으며, 각 시편에서 구한 접착강도와 응집 파단율의 상관 계수는 0.71이었다.

  • PDF

3종의 자가부식 프라이머의 상아질계면 접촉각 및 미세인장결합강도에 관한 연구 (Measurement of Contact Angle and Bond Strength Using 3 Different Self-Etching Primer)

  • 장석우;권호범;유현미;박동성;오태석;배광식
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.105-112
    • /
    • 2008
  • 본 연구의 목적은 3종의 자가부식 프라이머(Clearfil SE Bond, AdheSE, Tyrian) 사용시 상아질계면의 접촉각 및 미세인장결합강도를 측정하는 것이다. 연마된 상아질 표면에 3종의 자가부식 프라이머를 각각 적용한 후 접촉각을 측정하였으며 (n=30), One-way ANOVA를 사용하여 통계처리하였다. 미세인장결합강도측정을 위해서는 상아질 표면에 3종의 자가부식 프라이머 및 상아질 접착제를 각각 적용한 후 광중합 복합레진 (Z 250)을 5mm 두께로 쌓아 올렸다. 그 후 각 시편을 결합계면에 수직으로 분할한 뒤 (n=45) universal testing machine을 사용하여 미세인장강도를 측정하였고, Kruskal-Wallis test를 통하여 통계처리하였다. 접촉각 측정결과, AdheSE, Clearfil SE Bond, Tyrian 순으로 높은 접촉각을 보였으며 각 군간 통계적 유의성 있는 차이를 보였다 (p<0.05). 미세인장결합강도 측정결과 Clearfil SE Bond군과 AdheSE군은 유의성 있는 차이를 보이지 않았으며, Tyrian군은 Clearfil SE Bond 군이나 AdheSE 군에 비해 유의성 있게 작은 미세인장결합강도를 보였다.