• Title/Summary/Keyword: 레이저영상

Search Result 419, Processing Time 0.107 seconds

Laser induced ultrasound generation via reduced graphene oxide coated aluminum transmitter (환원된 산화 그래핀을 이용한 레이저 유도초음파의 64배 압력 상승 및 40dB 세기 상승)

  • Lee, Seok Hwan;Park, Mi-Ae;Yoh, Jai-Ick
    • Laser Solutions
    • /
    • v.15 no.4
    • /
    • pp.1-5
    • /
    • 2012
  • We demonstrate that reduced graphene oxide (rGO) coated thin aluminum film is an effective optoacoustic transmitter for generating high pressure and high frequency ultrasound previously unattainable by other techniques. The rGO layer of different thickness is deposited between a 100 nm-thick aluminum film and a glass substrate. Under a pulsed laser excitation, the transmitter generates enhanced optoacoustic pressure of 64 times the aluminum-alone transmitter. A promising optoacoustic wave generation is possible by optimizing thermoelasticity of metal film and thermal conductivity of rGO in the proposed transmitter for laser-induced ultrasound (LIUS) applications.

  • PDF

이동형 인공위성레이저추적용 광학계 개발

  • Na, Ja-Gyeong;Kim, Gwang-Dong;Jang, Jeong-Gyun;Jang, Bi-Ho;Han, In-U;Han, Jeong-Yeol;Park, Gwi-Jong;Park, Chan;Nam, Uk-Won;Im, Hyeong-Cheol;Park, Eun-Seo;Yu, Seong-Yeol;Seo, Yun-Gyeong;Mun, Il-Gwon;Gang, Yong-U
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.164.2-164.2
    • /
    • 2012
  • 인공위성레이저추적(SLR, Satellite Laser Ranging) 시스템은 인공위성까지 레이저를 발사하여 되돌아오는 시간간격을 측정함으로서 위성까지의 거리를 측정하는 시스템으로 현존하는 인공위성 궤도결정 시스템으로는 가장 정밀하다. 한국천문연구원은 우주추적 및 감시의 필요성이 증가함에 따라 2008년부터 40cm급 이동형 인공위성레이저추적 시스템을 개발을 시작하였고, 현재 개발을 완료하여 시험운영 중에 있다. 시스템 개발 과정 중에 발생할 수 있는 문제점들을 최소화하기 위해, 설계 단계에서 부품을 포함한 광기계 구조물에 대한 구조해석과, 실험실 프로토타입 구성 등을 실시하였다. 제작된 각 서브시스템별 조립 및 평가는 한국천문연구원이 보유한 광학계 조립 및 평가 시설을 이용하였다. 개발된 이동형 레이저 추적 시스템의 광학부는 추적마운트에 장착되었고, 현장 시험관측을 통해 수신광학계 및 광신호유도계의 정렬 및 제어항목 교정 등을 실시하였으며, 성공적으로 시험 영상 관측을 완료하였다. 이 발표에서는 이동형 레이저 추적 시스템 광학계의 개발 과정과 그 결과에 대해 보고한다.

  • PDF

Development of Camera Controller with Pointer Tracking Unit (카메라 컨트롤러를 이용한 포인터 추적 장치 개발)

  • Lee, Yong-hwan;Ju, Hyun-woong;Song, Sung-hae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.3
    • /
    • pp.111-117
    • /
    • 2008
  • Presentation with a projector and a laser pointer is widely used in seminar or conference. The function of a laser pointer in the presentation is just indicating a certain object. In this paper, to give a mouse-like function to a laser pointer, we implement a system that locates the track of a laser pointer. The system contains a FPGA that implements camera interface and noise filter. A software for ARM processor is programmed to analyze the spectrum of the captured image and track the pattern of a laser pointer with previously stored image. As a result, the tracking system could locate the position correctly most of time within 20m with 98% accuracy.

  • PDF

Damage Analysis of CCD Image Sensor Irradiated by Continuous Wave Laser (연속발진 레이저에 의한 CCD 영상센서의 손상 분석)

  • Yoon, Sunghee;Jhang, Kyung-Young;Shin, Wan-Soon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.690-697
    • /
    • 2016
  • EOIS(electro-optical imaging system) is the main target of the laser weapon. Specially, the image sensor will be vulnerable because EOIS focuses the incident laser beam onto the image sensor. Accordingly, the laser-induced damage of the image sensor needs to be identified for the counter-measure against the laser attack. In this study, the laser-induced damage of the CCD image sensor irradiated by the CW(continuous wave) NIR(near infrared) laser was experimentally investigated and mechanisms of those damage occurrences were analyzed. In the experiment, the near infrared CW fiber laser was used as a laser source. As the fluence, which is the product of the irradiance and the irradiation time, increased, the permanent damages such as discoloration and breakdown appeared sequentially. The discoloration occurred when the color filter was damaged and then the breakdown occurred when the photodiode and substrate were damaged. From the experimental results, LIDTs(laser-induced damage thresholds) of damages were roughly determined.

The Spreader Pose Determination Research Using CCD Camera and Laser Range Finder (CCD카메라와 레이저 거리미터기를 이용한 스프레더 자세 인식 방법 연구)

  • 이봉기;박수민;진태석;이장명;이권순
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.121-126
    • /
    • 2002
  • This paper introduces a method that can get information for the movement of a spreader and skew in order to drive ALS(Automatic Landing System) in the crane used at the harbor. Some methods that use 3D laser scanner sensor or laser range finder to obtain the information in ALS are used presently. But these have some defects respectively in economical efficiency and performance. Therefore, to recover these defects, we propose a method acquiring the information for the movement of a spreader and skew using CCD camera for image processing and laser range finder

  • PDF

Development of the 3D Rail Profile Reconstruction Method Improving the Measurement Accuracy of Railway Abrasion (레일 마모도의 측정 정밀도 향상을 위한 3차원 레일 프로파일 재구성 기법 개발)

  • Ahn, Sung-Hyuk;Kim, Man-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.533-539
    • /
    • 2010
  • The The contactless railway abrasion measurement system have to satisfy two conditions to increase the measurement accuracy as follows. The laser region projected on the rail have to be extracted without the geometrical distortion. The mapping of the acquired laser region data on the rail profile have to be matched with the cross section of rail, exactly. But, the conventional railway abrasion measurement system is required the post image processing with a camera model and a perspective transform for the exact mapping between the cross section of rail and the coordinate data extracted from a line laser region or the raw image obtained from a camera because the image captured from the camera has an oblique viewpoint. So, the measured rail profile data had limits to the measurement accuracy because of a discontinuity point. In this Paper, we propose the 3D rail profile reconstruction method to increase the accuracy of the railway abrasion measurement system applying the modified camera model and perspective transform to the image obtained from the bidirectional rail.

  • PDF

DOT Classification Code Extraction through 3-Dimensional Features (3차원 특징을 이용한 DOT 분류 코드 추출)

  • 김재한;심재창
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10b
    • /
    • pp.394-396
    • /
    • 2001
  • 본 논문의 목적은 타이어에 각인되어 있는 DOT 코드 문자를 효과적으로 추출하는데 있다. 기존의 DOT 문자 인식 방법에서는 카메라와 조명에 의한 2차원 영상에서 DOT 문자 추출을 시도하였는데, 타이어는 DOT 문자와 배경이 동일한 색상이고, 조명에 민감해서 DOT 문자의 추출이 용이하지 않았다. 그래서, 본 논문에서는 타이어의 DOT 문자를 조명에 거의 영향을 받지 않는 3자원 레이저 스캐너를 이용해서 획득하고, 획득된 영상에서 높이 값 정보를 추출했으며 추출된 높이 값 정보를 가진 영상에 패턴 인식 기법을 적용하여 DOT 문자를 효과적으로 추출할 수 있었다.

  • PDF

DIAGNOSIS OF EARLY CARIES WITH DYE-ENHANCED LASER FLUORESCENCE (레이저 형광과 광활성제를 이용한 초기 우식증의 진단)

  • Lee, Sang-Ho;Han, Kuk-Jae;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • To evaluate the quantitative nature of laser fluorescence(LF) and dye-enhanced laser fluorescence(DELF) on early enamel caries, artificial caries were induced on the bovine enamels and argon laser was irradiated on the surfaces of lesions. Fluorescence radiance from enamel specimen was recorded with CCD camera which was connected to PC image analyzing system. The difference of fluorescence of radiance(DFR) between the carious and the sound enamel in each sample of the LF and the DELF groups were measured by image analyzing program. The DFR of lesion surfaces measured with laser fluorescence and lesion depths were evaluated and the results are as follows: The caries lesions were discriminated from sound enamels by the darkness with LF and by the brightness with DELF. The DELF was more sensitive than the LF at the earlier stage of demineralization.

  • PDF

Measurement Technique of Turbulent Flows (난류유동의 측정기술)

  • 성형진;고상근
    • Journal of the KSME
    • /
    • v.34 no.9
    • /
    • pp.678-687
    • /
    • 1994
  • 이 글에서는 상대측정방법의 예로서 열선 유속계, 절대측정방법의 예로서 레이저 도플러 유속계, 가시화기법에 대한 전반적인 설명을 통하여 난류측정에 대한 이해를 돕고자 한다. 열선유속계와 레이저도플러유속계는 응답특성이 난류측정에 적합한 측정기술로서 입증되어 있지만, 가시화 기법에 의한 난류측정은 3차원 유동장을 동시에 처리할 수 있는 장점에도 불구하고 영상처리에 많은 시간이 필요하므로 아직까지 계속적인 연구가 이루어지고 있다.

  • PDF

레이저 변위 센서를 이용한 검출에 관한 연구

  • 박용환;김재옹
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.556-560
    • /
    • 1993
  • 최근 모든 산업에 있어서 자동화에 대한 요구가 높아지고 있다. 모든 자동화는 힘들고 어려운 작업을 기계가 인간을 대신하여 수행하며 품질 및 생산성을 향상시킨다는 관점에서 끊임없이 추구되고 있다. 용접 자동화도 그 예외는 아니어서 용접 구조물 제작의 경우, 임의의 용접 경로를 추적하는 방법과 공정 변수의 제어법 등이 현재 연구되고 있다. 특히 용접 공정중 용접선 경로 변화를 측정할 수 있는 센서가 용접 공정의 자동화에 필수적이다. 이러한 센서중에는 아크센서, 시각센서, 초음파센서, 레이저센서가 있으며, 이중 널리 이용되고 있는 것은 팁-모재간의 거리변화에 따른 전류 또는 전압 변화를 모델링하여 위치 정보로 이용하는 아크센서와, 카메라를 이용한 영상 정보를 처리함으로써 토치가 이동해야 항 위치를 찾는 시각센서가 있다.

  • PDF