• Title/Summary/Keyword: 라이스

Search Result 415, Processing Time 0.024 seconds

A Study on Segmentation and Volume Calculation of the White Matter and Gray Matter for Brain Image Processing (뇌 영상처리를 위한 백질과 회백질의 추출 및 체적 산출에 관한 연구)

  • Kim, Shin-Hong
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.21-27
    • /
    • 2006
  • This paper is for the segmentation and volume calculation of the white matter and gray matter from brain MRI. We segment white matter, gray matter and CSF from the Brain image in the normal and abnormal person, and calculate the volume of segmented tissue. In this paper, we present a new method of extracting white matter, gray matter and CSF and calculation its volume from MR images for brain. And we have developed the determining method of threshold that can extract white matter and gray matter from MR image for brain through the analysis of gray values represented by ratio of each component. We proposed the calculation method of volume for white matter and gray matter by using number of extracted pixels in each slice. This algorithm input CSF/Head volume ratio and age of patient and calculates discriminant value through discriminant expression, classifies normal and abnormal using calculated discriminant value. As a result, we could blow that white matter and gray matter volume decrease and CSF volume increase as we grow gold.

An Effcient Two-Level Hybrid Signature File Method for Large Text Databases (대용량 텍스트 데이터베이스를 위한 효율적인 2단계 합성 요약 화일 방법)

  • Yoo, Jae-Soo;Gang, Hyeong-Il
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.4
    • /
    • pp.923-932
    • /
    • 1997
  • In this paper, we propose a two-level hybrid signature file method(THM) to dffciently deal with large txt databases that use a term discrimination concept.In addition, we apply Yoo's clustering scheme to the two-level hybeid signature file method. The clustering schme groups similar signatures together according to the similarity of the highly discriminatiory tems so that we may achive better performance on retrival. The space-time ana-lyhtical model of the proposed two-level hybrid method is provided. Based on the analytical model and experiments, we compare it with the exsting methods, i.e. the bit-sliced method(BM), the-level method(TM), and the hybrid method(HM). As a result, we show that THM achives the best retrival performance in a large database with 100,000 records when the mumber fo matching records is less than 160.

  • PDF

Implementation of Multi-channel Concurrent Detection Homodyne Frequency-domain Diffuse Optical Imaging System (다채널 동시측정을 적용한 호모다인 주파수영역 확산 광 이미징 시스템의 구현)

  • Jun, Young Sik;Baek, Woon Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • In this paper, we developed a frequency-domain diffuse optical imaging (DOI) system for imaging non-invasively using near-infrared (NIR) light sources and detectors. 70-MHz modulation and a homodyne scheme were adopted. By calibration of the coupling coefficients, concurrent detection measurements by 4 detector sets were optimized. We presented experimental reconstruction images of absorption and scattering coefficients in a liquid phantom, located an anomaly in the phantom and determined its optical properties. The images by the multi-channel concurrent detection were improved over the results by single-channel sequential detection. Tomographic slices of absorption and scattering coefficients in the phantom with an anomaly were also presented.

Short-axis cine MR 영상을 이용한 심박출량 측정 : Threshold segmentation 기법의 적용

  • 강원석;최병욱;최규옥;정해조;이상호;유선국;김희중
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.79-79
    • /
    • 2003
  • 심실의 내부는 유두근이나 trabecular와 같은 해부학적 구조물들로 인해 복잡한 형태를 띄고 있다. 그러한 복잡한 구조는 MR 영상을 이용한 심박출량 측정시 오차를 유발시킬 수 있으며, 만약 오차를 줄이기 위해 수작업을 하게 된다면 많은 수고와 시간이 필요하게 될 것이다. 본 연구에서는 threshold 기법을 이용하여 짧은 시간동안에 정확하게 복잡한 구조를 가진 심실의 심박출량을 측정하고자 하였다. 7 명의 환자에 대해 l.5T 급 MR 장치 (INTERA, Philips, Netherlands)를 이용하여 short-axis cardiac MR 영상을 획득하였다. 한 환자에 대해서 8개에서 10개의 슬라이스 영상을 8-10 mm의 두께로, 하나의 심장주기(cardiac cycle)동안 일정한 시간간격으로 25 개의 영상을 획득하였으며, 펄스시퀀스로는 ECG-gated segmented balanced fast field echo (TR/TE = 3ms/1.56ms)를 사용하였다. 획득된 영상은 PC(threshold 기법)와 workstation (기존의 수동 및 자동 segmentation 기법)로 DICOM 형태로 전송되었다. 측정은 IDL을 이용하여 자체 제작된 소프트웨어와 상용화된 소프트웨어 (MASS 5.0, MEDIS, Netherlands)를 이용하여 분석되었다. MR 영상에서 심내벽 부위를 추출하기 위하여 자체제작된 소프트웨어로는 threshold 기법을, 상용 소프트웨어로는 기존의 수동 및 자동 기법을 이용하였다. 심박출량은 최대수축기와 이완기 사이의 용적 차이로써 계산되었으며, 좌심실 및 우심실 모두에 대해 수행되었다. 또한, 해부학적 구조의 복잡도에 따른 측정방법의 정확도를 확인하기 위해 유두근 및 trabecular의 hypertrophy의 정도를 3 단계로 구분하고 측정된 값들을 통계적으로 분석하였다. Hypertrophy가 약한 그룹에서는 기존의 수동방식과 threshold 기법간의 의미있는 차이가 없었으며 (p=0.372), 기존의 수동 및 자동방식 간에도 큰 차이가 없었다 (p=0.298). 그러나, hypertrophy가 심한 그룹에서는 수동방식 및 자동방식 측정치 사이에 통계적으로 유의한 차이를 보임을 알 수 있었다 (p=0.044). 그러나, threshold 기법과 수동방식 사이에는 유의한 차이가 없었다 (p=0.l94). 분석시간은 threshold 기법이 기존의 수동방식에 비해서 두배정도 빠르다는 것을 알 수 있었다, Threshold 기법은 심박출량 측정에 있어서 정확하면서도 빠른 결과의 도출이 가능했으며, 특히 심내벽의 구조가 복잡한 경우에 그 효과가 증대됨을 알 수 있었다.

  • PDF

Coding Efficiency Improvement for Identical Motion Information of Bi-prediction Mode within the GPB Slcice of HEVC (HEVC의 GPB 슬라이스에서 양예측 모드의 동일 움직임 정보에 대한 성능 향상 방안)

  • Kim, Sang-Min;Kim, Kyung-Yong;Park, Gwang-Hoon;Kim, Hui-Yong;Lim, Sung-Chang;Lee, Jin-Ho
    • Journal of Broadcast Engineering
    • /
    • v.16 no.6
    • /
    • pp.1069-1072
    • /
    • 2011
  • This paper proposes the method which reduces complexity and improves coding efficiency by solving a problem of HEVC bi-prediction. In current HM 3.0, it is frequently occurred that L0 motion information and L1 motion information are identical in blocks which are bi-predicted. In this case, L1 motion vector is replaced by non-zero motion vector which belongs to first available neighbor block of current block. If they are still identical, prediction mode is replaced by uni-prediction. As an experimental result, in LD(Low-Delay) case, decoding time is reduced roughly 2%~5% and coding gain is roughly 0.3%~0.5% compared with the HM 3.0 anchor.

A Simple Transcoding Method for H.264 Coding System (H.264 부호화시스템에서 간단한 비트열 변환 기법)

  • Yang, Young-Hyun;Kwon, Soon-Kak
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.818-826
    • /
    • 2006
  • In this paper, we investigate the relationship of bitrate and quantization parameter needed for the trans-coding method that makes the H.264 bitstream of a particular bitrate to the other titrate. Also we propose the new method in order to transcode the titrate between H.264 video coded bitstreams. The proposed transcoding method updates the model parameters from previous picture or slice by using the approximated relationship of bitrate and quantization step-size and finds the target quantization step-size, and then generates the target titrate by simple coding processing just after requantization. Therefore, the proposed method does not need the complex bitrate control and converts to the target titrate by simple implementation. From simulation, we can see that the proposed method transcodes exactly to an assigned target bitrate for the four test sequences with different their characteristics.

  • PDF

Water-Fat Imaging with Automatic Field Inhomogeneity Correction Using Joint Phase Magnitude Density Function at Low Field MRI (저자장 자기공명영상에서 위상-크기 결합 밀도 함수를 이용한 자동 불균일 자장 보정 물-지방 영상 기법)

  • Kim, Pan-Ki;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.57-66
    • /
    • 2011
  • Purpose : A new inhomogeneity correction method based on two-point Dixon sequence is proposed to obtain water and fat images at 0.35T, low field magnetic resonance imaging (MRI) system. Materials and Methods : Joint phase-magnitude density function (JPMF) is obtained from the in-phase and out-of-phase images by the two-point Dixon method. The range of the water signal is adjusted from the JPMF, and 3D inhomogeneity map is obtained from the phase of corresponding water volume. The 3D inhomogeneity map is used to correct the inhomogeneity field iteratively. Results : The proposed water-fat imaging method was successfully applied to various organs. The proposed 3D inhomogeneity correction algorithm provides good performances in overall multi-slice images. Conclusion : The proposed water-fat separation method using JPMF is robust to field inhomogeneity. Three dimensional inhomogeneity map and the iterative inhomogeneity correction algorithm improve water and fat imaging substantially.

Web-Based Distributed Visualization System for Large Scale Geographic Data (대용량 지형 데이터를 위한 웹 기반 분산 가시화 시스템)

  • Hwang, Gyu-Hyun;Yun, Seong-Min;Park, Sang-Hun
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.6
    • /
    • pp.835-848
    • /
    • 2011
  • In this paper, we propose a client server based distributed/parallel system to effectively visualize huge geographic data. The system consists of a web-based client GUI program and a distributed/parallel server program which runs on multiple PC clusters. To make the client program run on mobile devices as well as PCs, the graphical user interface has been designed by using JOGL, the java-based OpenGL graphics library, and sending the information about current available memory space and maximum display resolution the server can minimize the amount of tasks. PC clusters used to play the role of the server access requested geographic data from distributed disks, and properly re-sample them, then send the results back to the client. To minimize the latency happened in repeatedly access the distributed stored geography data, cache data structures have been maintained in both every nodes of the server and the client.

A Unified Gradient Shape on the Slice-Selection Axis for Flow Compensation (스핀에코 펄스 시퀀스의 슬라이스 선택방향에서 혈류 보상을 위한 통일 경사자장법 연구)

  • Pickup, Stephen;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.70-80
    • /
    • 2006
  • Spin echo gradient moment nulling pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. A new technique was introduced for flow compensation that minimized echo time and effectively suppresses unwanted echoes on the slice selection gradient axis in spin echo sequences. A unified gradient shape was used in all orders of flow compensation up to the third order. A dual-purpose gradient was applied for flow compensation and to reduce unwanted artifacts. The sequences were used to generate images of phantoms and/or human brains. This technique was especially good at reducing eddy currents and artifacts related to imperfection of the refocusing pulse. The developed sequences were found to have shorter echo times and better flow compensation in through-plane flow than those of the previous models that were used by other investigators.

  • PDF

Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images (CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.941-946
    • /
    • 2019
  • Computed tomography (CT) has been increasing in frequency and indications for use in clinical diagnosis and treatment decisions. Multidetector CT has the advantage of shortening the inspection time and obtaining a high resolution image compared to a single detector CT, but has been pointed out the disadvantage of increasing the radiation exposure. In addition, when the low tube voltage is used to reduce the exposure dose in the CT, noise increases relatively. In the existing method, the method of finding the optimal image quality using the method of adjusting the parameters of the image reconstruction method is not a fundamental measure. In this study, we applied a double-tree complex wavelet algorithm and analyzed the results to maintain the normal signal and remove only noise. Experimental results show that the noise is reduced from 8.53 to 4.51 when using a complex oriented 2D method with 100kVp and 0.5sec rotation time. Through this study, it was possible to remove the noise and reduce the patient dose by using the optimal noise reduction algorithm. The results of this study can be used to reduce the exposure of patients due to the low dose of CT.