• Title/Summary/Keyword: 라온

Search Result 7, Processing Time 0.019 seconds

A Study Shrinkage Analysis of Injection mold using Regression Analysis (회귀분석법을 이용한 사출금형의 수축률 분석에 관한 연구)

  • RYU, M.R.;BAE, H.E.;PARK, J.H.;PARK, J.S.;PARK, S.H.;LEE, D.H.;LEE, S.B.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • It is not easy to predict the shrinkage rate of a plastic injection mold in its design process. The shrinkage rate should be considered as one of the important performances to produce the reliable products. The shrinkage rate can be determined by using the CAE tools in the design produces. However, since the analysis can take minutes to hours, the high computational costs of performing the analysis limit their use in design optimization. Therefore this study was carried out to presume for mutual relation of analysis condition to get the optimum average shrinkage by regression analysis. The results shown that coefficient of determination of regression equation has a fine reliability over 87% and regression equation of average shrinkage is made by regression analysis.

The factors affecting turnover intention of dental hygienists (치과위생사의 이직의도에 영향을 미치는 요인)

  • Ryu, Hae-Gyum;Kim, Ju-Yeob;Park, Bin-Jeong
    • Journal of Korean Clinical Health Science
    • /
    • v.8 no.2
    • /
    • pp.1408-1416
    • /
    • 2020
  • Purpose; The purpose of this study was to identify the factors affecting turnover intention of dental hygienists and to find ways to prevent turnover in advance. Methods: The subjects of this study were dental hygienists working in dental hospitals in Busan and Gyeongnam. from 1 July 2019 to 30 August 2019 a number of total 203. The structured questionnaire was surveyed and analyzed by self- entry. The collected data were analyzed using an IBM SPSS ver. 20.0. Results: Night work 'none' and 'at least twice a week' was higher a job grievance(p<0.001), The work environment(p<0.001), job congnition(p<0.001), duty satisfaction(p<0.05) and external environment(p<0.001) of 'none' and 'once a week' was higher. The number of patient of 'less then 40' and 'over 80 groups' was high a job grievances(p<0.001). '60-79 groups' was higher a work environment(p<0.05), '40-59 groups' and 60-79 groups' was higher a job congnition(p<0.001), duty satisfaction(p<0.001), and external environment(p<0.001), coworker relationship(p<0.05), were high in 'over 80 groups'. The factors affecting turnover intention was investigated a job congnition (β = -0.384), coworker relationship (β = -0.174), and job grievances (β = -0.172). the turnover intention was higher in ' lower the job congnition', 'lower job grievances', ' bad coworker relationship' Conclusions: In order to raise the job congnition of dental hygienists, it is necessary to have a legislative provision for the practical work of dental hygienists, a stable job security and pride in the job, a sense of achievement in the work. also that is necessary to have program development for communication of coworker.

A Study on Symptom Improvement and Satisfaction of Inpatients Received Traditional Korean Medicine for Enhanced Recovery after Surgery (ERAS) after Gynecological Surgery (부인과 수술 후 한방 조기 회복 치료를 받은 입원 환자에 대한 호전도 및 만족도 조사)

  • Yoon, Hee-Jae;Kim, Hae-Won;Lee, Ji-Yeon;Yoo, Jeong-Eun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.35 no.3
    • /
    • pp.88-104
    • /
    • 2022
  • Objectives: The purpose of this study is to report the effectiveness and satisfaction of traditional Korean medicine (TKM) for enhanced recovery after surgery (ERAS) after gynecological surgery. Methods: The study is conducted by analyzing the medical records of hospitalized patients in a Korean medicine hospital. Sixty-five patients who received TKM for ERAS after gynecological surgery from May 2020 to July 2021 were included. We performed statistical analysis by using SPSS ver. 25.0. To verify the effect of TKM for ERAS, we analyzed improvement of symptoms. Also, we analyzed survey of patients' satisfaction to verify the satisfaction of TKM for ERAS. Results: Among the symptoms of pain, there was a statistically significant decrease in all types of pain on the questionnaire. Other systemic symptoms showed statistically significant improvement in all symptoms on the questionnaire. The satisfaction level questionnaires for TKM for ERAS showed a mean value of 4.37±0.63 out of 5-point scale. Especially, herbal medicine, acupuncture, and moxibustion showed high satisfaction without dissatisfaction. Conclusions: The result has shown that TKM for ERAS after gynecological surgery is effective and the satisfaction of the patients is high. Further study on TKM for ERAS for quality of life assessment is needed.

Suggestion of Analytical Technique Applying Multi-Linear Models for Analysis of Skin Shear Behavior of Tension-Type Ground Anchors in Weathered Soil (풍화토 정착 인장형 앵커에서 주면전단거동분석을 위한 다중선형모델 적용 해석기법의 제안)

  • Jeong, Hyeon-Sik;Lee, Yeong-Saeng
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.5-19
    • /
    • 2018
  • The characteristics of the skin shear stress distribution for the fixed length of the ground anchor are extremely nonlinear and the engineering mechanisms are complex relatively. So it is difficult to design the anchors simulating the actual behavior by considering various soil conditions and nonlinear behavior. Due to these limits, constant skin shear stress distributions for the whole fixed length of the ground anchor are usually assumed in the design for the sake of convenience. In this study, to assess the pull-out behavior of the tension-type ground anchors, the in-situ pull-out tests in weathered-soil conditions were carried out. Based on the test results, the skin shear behaviors for the fixed length of tension-type ground anchors were established and the multi-linear slip shear model predicting this behavior and an analytical technique applying this model were proposed. From the similarity between the results of the in-situ pull-out tests and those of the analytical technique, the applicability and availability of the multi-linear slip shear model and the proposed analytical technique were verified. The maximum shear stress was developed at the start point of the fixed length acting with the smaller load than the maximum pull-out load but the minimum shear stress was developed at the start point of the fixed length and the maximum shear stress was developed at the point apart from the start point of the fixed length after the maximum pull-out load.

Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON (한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션)

  • Bae, Jae-Beom;Cho, Byung-Cheol;Kwak, Jung-Won;Park, Woo-Yoon;Lim, Young-Kyung;Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The purpose of the Monte Carlo simulation study was to provide the optimized nozzle design to satisfy the beam conditions for biomedical researches in the Korean heavy-ion accelerator, RAON. The nozzle design was required to produce $C^{12}$ beam satisfying the three conditions; the maximum field size, the dose uniformity and the beam contamination. We employed the GEANT4 toolkit in Monte Carlo simulation to optimize the nozzle design. The beams for biomedical researches were required that the maximum field size should be more than $15{\times}15cm^2$, the dose uniformity was to be less than 3% and the level of beam contamination due to the scattered radiation from collimation systems was less than 5% of total dose. For the field size, we optimized the tilting angle of the circularly rotating beam controlled by a pair of dipole magnets at the most upstream of the user beam line unit and the thickness of the scatter plate located downstream of the dipole magnets. The values of beam scanning angle and the thickness of the scatter plate could be successfully optimized to be $0.5^{\circ}$ and 0.05 cm via this Monte Carlo simulation analysis. For the dose uniformity and the beam contamination, we introduced the new beam configuration technique by the combination of scanning and static beams. With the combination of a central static beam and a circularly rotating beam with the tilting angle of $0.5^{\circ}$ to beam axis, the dose uniformity could be established to be 1.1% in $15{\times}15cm^2$ sized maximum field. For the beam contamination, it was determined by the ratio of the absorbed doses delivered by $C^{12}$ ion and other particles. The level of the beam contamination could be achieved to be less than 2.5% of total dose in the region from 5 cm to 17 cm water equivalent depth in the combined beam configuration. Based on the results, we could establish the optimized nozzle design satisfying the beam conditions which were required for biomedical researches.