복합지지구조를 가진 뜬바닥 시스템 (II) (Floating Floor of Multi-supporting System ( II ))

  • 박영환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.293-295
    • /
    • 2004
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating floor. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF

복합지지구조를 가진 뜬바닥 시스템 (Floating Floor of Multi-Supporting System)

  • 박영환;정환돈;오호진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.928-931
    • /
    • 2003
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating nut. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF

뜬바닥 구조에서 층간차음재의 계면구조 및 단면형상이 충격진동량 저감효과에 미치는 영향 (Effect of the Interface Structure and Section Shape of Isolation Material in Floating Floor Impcat Vibration Level Decrease)

  • 김범수;양수영;제현수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.296-299
    • /
    • 2004
  • 단열 완충재의 하부단면에서 양각 형태가 전체 면적에서 .차지하는 비율에 따라 진동 충격음 저감량을 실험하였다. 양각 형태가 차지하는 비율이 높더라도 진동 충격음 저감량에는 큰 성능을 나타내지 않았다. 바닥 구조에서 슬래브와 상판 사이에 단열완충재를 설치할 경우 중량 충격음이 오히려 증가하는 경향을 보이고 있다. 이것은 뜬 바닥 구조에서 완충재의 설치로 인하여 슬래브와 상판간의 거동이 다르게 발생하기 때문이다.

  • PDF

바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구 (An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction.)

  • 최경석;석원균;목지욱;신이섭;김형준;김정진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

뜬바닥구조를 이용한 선실 바닥충격음 저감에 관한 연구 (A Study of Floor Impact Noise Reduction of Cabin Using Floating Floor)

  • 김현실;김봉기;차선일;김영수
    • 대한조선학회논문집
    • /
    • 제41권5호
    • /
    • pp.41-47
    • /
    • 2004
  • In this paper, floor impact noise reduction in cruise ship cabin is studied. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t panel is used to construct wall and ceiling inside the steel structure. Various floating floor systems are tested for which normalized impact noise is measured according to ISO 140-7. In addition, floor SBN (Structure-borne Noise) and floor damping are measured to study the effect of floating floor structure. It is shown that VL(Visco-elastic Layer) is more effective when hard plates are added above the VL.

옥상 뜬바닥 구조공법의 접착제 최적 배합비 산정을 위한 부착성능 실험 (Bond Performance Test for Optimum Mixing Ratio Calculation of the Floatig Floor Method on Roof-top)

  • 서유현;박준모;김옥규;정일기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2016
  • Waterproofing methods for applying to roof-top in the building are various, but it is not enough to development, which are simplified and low-cost method for old building. Especially, these buildings have not only a low insulation, but a disadvantage for energy. A floating floor method is necessary for this. This study performs an experimentt about bonding capacity of complex panel for waterproofing and heat insulation. The bond strength experiment is based on KS F 4716, and it is considered by bond mix proportion about panel and slab.

  • PDF

우레탄 보드를 활용한 옥상 뜬바닥 구조공법의 휨강도에 관한 기초적 실험 (Foundational Experiments about Bending Strength of Floating Floor Method on Roof-top by using a Polyurethane Board)

  • 박길범;박준모;김옥규;정일기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.15-16
    • /
    • 2016
  • The roof-top of deteriorated building is necessary to improve that performance of waterproof and heat insulation is lowered. However, the existing method is difficult to supply due to complicated process and high cost. Therefore, practical condition and demand for occupant considered, it is necessary to develop inexpensive and easy method, such as a floating floor method using thermal insulation. This study is experiments on foundational experiment was conducted on the bending strength. A polyurethane board for experiment forms a square and it has various size that 25cm, 33cm, 50cm, and 100cm. Meanwhile, the uniform load of 200kg/㎡ which general working load is applied to the bending strength.

  • PDF

뜬바닥구조의 균열강도 평가 (Evaluation of Cracking Strength of Floating Floor System)

  • 이정윤;이범식;전명훈;김종문
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.53-61
    • /
    • 2015
  • 이 연구에서는 층간소음을 억제하기 위하여 사용되는 뜬바닥구조의 구조거동을 실험을 통하여 평가하였다. 최근 층간소음을 억제하기 위하여 연질의 완충재가 사용되며, 이로 인하여 마감모르타르나 기포콘크리트에 균열이 발생할 가능성이 높아지고 있다. 이 연구에서는 완충재의 강성, 하중가력 위치, 바닥 구성층을 변수로 하는 16개의 2방향 뜬바닥구조를 실험하였다. 실험에 의하면 완충재의 강성은 뜬바닥구조의 균열강도에 큰 영향을 미치며 완충재의 할선계수가 0.2MPa인 경우에 낮은 강도에서 균열이 발생하였다. 또한 슬래브의 단부나 모서리에 하중이 가력될 경우에 균열강도가 감소하였다. 뜬바닥구조를 이루고 있는 마감모르타르는 균열강도에 영향을 주었지만 기포콘크리트는 균열강도에 영향을 주지 않았다.

共同住宅 뜬바닥構造의 바닥 衝擊音레벨 測定 (Measurements of the floor impact sound level for floating screeds in apartment house)

  • 박병전;신영무
    • 한국음향학회지
    • /
    • 제11권2호
    • /
    • pp.38-49
    • /
    • 1992
  • 고체음은 건축음향에서 가장 중요한 인자의 하나이다. 그럼에도 불구하고 건축음향설계에서 그 거동을 예측하는 연구는 아직 찾아볼 수 없는 실정이다. 여기에 바닥충격음 제어의 가장 확실한 방법중의 하나인 콘크리트 뜬바닥구조를 개발하여, 이 구조의 층ㅇ격음 차단성능을 기존바닥과 비교하고자 한다. 이를 위하여 5개소에 21개 샘플을 시공하고 그 성능을 KS F 2810의 규정에 따라 측정하였으며, 비교분석은 차음등급의 기준주파수 특성을 쓰고, JIS A 1419의 규정에 의해 구한 차음등급에 따랐다. 결과는 표 3.1의 번호 12의 구조이외는 크게 바닥충격음의 개선효과를 기대할 수 없었고 기타는 자료의 축적에 뜻이 있다 하겠다.

  • PDF