• Title/Summary/Keyword: 뜬바닥

Search Result 32, Processing Time 0.023 seconds

Floating Floor of Multi-supporting System ( II ) (복합지지구조를 가진 뜬바닥 시스템 (II))

  • 박영환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.293-295
    • /
    • 2004
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating floor. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF

Floating Floor of Multi-Supporting System (복합지지구조를 가진 뜬바닥 시스템)

  • 박영환;정환돈;오호진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.928-931
    • /
    • 2003
  • In this research, we suggest the effective technique that the thickness of slab isn't increased, and considering proper shock absorbing material and supporting point, we make the floating floor which has multi-supporting system floating nut. As the result, it is effective in reduction of heavy weight system as well as one of light weight

  • PDF

Effect of the Interface Structure and Section Shape of Isolation Material in Floating Floor Impcat Vibration Level Decrease (뜬바닥 구조에서 층간차음재의 계면구조 및 단면형상이 충격진동량 저감효과에 미치는 영향)

  • 김범수;양수영;제현수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.296-299
    • /
    • 2004
  • 단열 완충재의 하부단면에서 양각 형태가 전체 면적에서 .차지하는 비율에 따라 진동 충격음 저감량을 실험하였다. 양각 형태가 차지하는 비율이 높더라도 진동 충격음 저감량에는 큰 성능을 나타내지 않았다. 바닥 구조에서 슬래브와 상판 사이에 단열완충재를 설치할 경우 중량 충격음이 오히려 증가하는 경향을 보이고 있다. 이것은 뜬 바닥 구조에서 완충재의 설치로 인하여 슬래브와 상판간의 거동이 다르게 발생하기 때문이다.

  • PDF

An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction. (바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구)

  • Choi, Kyung-Suk;Seok, Won-Kyun;Mauk, Ji-Wook;Shin, Yi-Seop;Kim, Hyung-Joon;Kim, Jeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

A Study of Floor Impact Noise Reduction of Cabin Using Floating Floor (뜬바닥구조를 이용한 선실 바닥충격음 저감에 관한 연구)

  • Kim, Hyun-Sil;Kim, Bong-Ki;Cha, Sun-Il;Kim, Young-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.5
    • /
    • pp.41-47
    • /
    • 2004
  • In this paper, floor impact noise reduction in cruise ship cabin is studied. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t panel is used to construct wall and ceiling inside the steel structure. Various floating floor systems are tested for which normalized impact noise is measured according to ISO 140-7. In addition, floor SBN (Structure-borne Noise) and floor damping are measured to study the effect of floating floor structure. It is shown that VL(Visco-elastic Layer) is more effective when hard plates are added above the VL.

Bond Performance Test for Optimum Mixing Ratio Calculation of the Floatig Floor Method on Roof-top (옥상 뜬바닥 구조공법의 접착제 최적 배합비 산정을 위한 부착성능 실험)

  • Seo, Yu-Hyun;Park, Jun-Mo;Kim, Ok-Kyue;Jung, Il-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.111-112
    • /
    • 2016
  • Waterproofing methods for applying to roof-top in the building are various, but it is not enough to development, which are simplified and low-cost method for old building. Especially, these buildings have not only a low insulation, but a disadvantage for energy. A floating floor method is necessary for this. This study performs an experimentt about bonding capacity of complex panel for waterproofing and heat insulation. The bond strength experiment is based on KS F 4716, and it is considered by bond mix proportion about panel and slab.

  • PDF

Foundational Experiments about Bending Strength of Floating Floor Method on Roof-top by using a Polyurethane Board (우레탄 보드를 활용한 옥상 뜬바닥 구조공법의 휨강도에 관한 기초적 실험)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue;Jeong, Il-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.15-16
    • /
    • 2016
  • The roof-top of deteriorated building is necessary to improve that performance of waterproof and heat insulation is lowered. However, the existing method is difficult to supply due to complicated process and high cost. Therefore, practical condition and demand for occupant considered, it is necessary to develop inexpensive and easy method, such as a floating floor method using thermal insulation. This study is experiments on foundational experiment was conducted on the bending strength. A polyurethane board for experiment forms a square and it has various size that 25cm, 33cm, 50cm, and 100cm. Meanwhile, the uniform load of 200kg/㎡ which general working load is applied to the bending strength.

  • PDF

Evaluation of Cracking Strength of Floating Floor System (뜬바닥구조의 균열강도 평가)

  • Lee, Jung-Yoon;Lee, Bum-Sik;Jun, Myoung-Hoon;Kim, Jong-Mun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • This paper reports the test results of the floating floor system used to reduce the floor noise of apartment buildings. Recently, many soft resilient materials placing between the reinforced concrete slab and finishing mortar are used. The resilient material should not only reduce the floor impact sound vibration from the floor but also support the load on the floor. Thus, even if soft resilient materials satisfy the maximum limitation of light-weight impact sound and heavy-weight impact sound, these materials may not support the load on the floor. The experimental program involved conducting sixteen sound insulation floating floor specimens. Three main parameters were considered in the experimental investigation: resilient materials, loading location, and layers of floor. Experimental results indicated that the stiffness of resilient material significantly influenced on the structural behavior of floating floor system. In addition, the deflection of the floating concrete floor loaded at the side or coner of the specimen was greater than that of the floor loaded at the center of the specimen. However, the aerated concrete did not effect on the cracking strength of floating floor system.

Measurements of the floor impact sound level for floating screeds in apartment house (共同住宅 뜬바닥構造의 바닥 衝擊音레벨 測定)

  • Park, Byeong-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.38-49
    • /
    • 1992
  • The structure borne sound is one of the most important factor in building acoustics. Nevertheless, there is not yet sufficient knowledge to predict its behavior in preparing the acoustical design of a building. We are concerned with the concrete floating floor construction, which is one of the most promising ways to control floor impact sound. This study is to develop floating screeds isolated from the conventional concrete floor structures, to improve the concrete floor systems for the purpose of the good sound insulation performance which protects the propagation of the structure borne sound. Floor impact sound in many apartment house buildings and developed floating floors was measured, and we can save many floor impact sound data.

  • PDF