• Title/Summary/Keyword: 디지털 이동방사선검사 장비

Search Result 3, Processing Time 0.021 seconds

Bacteriological Research for the Contamination of Digital Portable Radiography (디지털 이동방사선검사에서의 세균 오염도)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

Development of Educational Training Assistance System on Digital Mobile X-ray Equipment (디지털 이동형 X선 장비의 교육용 보조 시스템 개발)

  • Kim, Ji-Soo;Yun, Ju-Hee;Lee, Ji-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.1305-1307
    • /
    • 2021
  • 이동형 X선 장비를 이용하는 초보자들이 운전에 대한 부담감을 줄이고 손쉽게 훈련하면서도 장비의 손상을 방지하면서 교육할 수 있도록 안전한 X선 검사를 통한 국민보건향상을 위해 디지털 이동형 X선 장비의 교육용 보조 시스템을 개발하고자 하였다. 본 시스템은 교육 훈련을 위한 전용 코스 환경 개발, 장애물 인식을 위한 라인트레이서 탐색 및 초음파 센서 개발로 구성되어 있다. 학생들을 위한 이동형 X선 장비 교육을 위한 보조 시스템 개발로 이동형 X선 장비 전용 코스 환경은 교육을 위해 ㄷ형, T형, S형 등의 다양한 형태이다. 이 기능을 이용하여 각각의 코스에서 교육생들이 운전의 오류를 화면에 점수화하여 실무능력을 높일 수 있으리라 기대된다.

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.