• Title/Summary/Keyword: 디지털 위상검출기법

Search Result 15, Processing Time 0.022 seconds

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

Development of High-Speed Measuring Instrument for RF Frequency High Frequency Signal Detection (RF 주파수대 고주파 신호검출을 위한 고속계측기 개발)

  • Park, Seong-Mi;Song, kwang-Suk;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.469-470
    • /
    • 2017
  • 디지털 계측기는 전압 또는 전류 한주기에 대하여 여러 번 샘플링 하여 실효치를 구하고 위상은 전압영점에서 카운터를 시작하여 전류 영점에서 그 카운터의 값에 의해 전력을 구하는 것이 일반적이다. 그러나 계측대상 주파수가 샘플링 주파수와 유사한 경우 사실상 전력 계측이 불가능하게 되는 취약점을 안고 있다. 따라서 본 논문에서는 계측대상 주파수가 샘플링 주파수와 유사한 경우 샘플링 시프트 기능을 사용하여 계측하는 정규화 기법과 이를 이용하여 DFT를 사용하여 각 차수의 고조파 성분을 분석할 수 있는 알고리즘을 제안한다. 또한 제안된 방식을 Psim을 이용한 시뮬레이션을 통하여 그 타당성을 검증하였다.

  • PDF

A Study on Novel Hybrid Type Encoder Design for the Position Control with the High-resolution (고정도 위치제어용 Hybrid Type Encoder에 관한 연구)

  • Cho S. E.;Lee S. H.;Song S. G.;Park S. J.;Kwon S. J.;Kim C. U.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.87-94
    • /
    • 2005
  • This paper is about the compensation of phase angle error and amplitude difference in stationary 2 pole coordinates by the installation variation of sensor at low cost high resolution digital hybrid encoder. To solve the problem of amplitude difference at the existing hybrid encoder, we normalized the relative magnitude of the two analog signals. and also to solve the problem of installation variation when installed the sensor, we rotate the stationary 2 pole coordinates to compensate the location error of sensor. and we used and tested the QEP function and A/D port in DSP(TMS320F2812) to verify the mentioned proposed method.

Study on Signal Processing in Eddy Current Testing for Defects in Spline Gear (스플라인 기어부 결함의 와전류검사 신호처리에 관한 연구)

  • Lee, Jae Ho;Park, Tae Sung;Park, Ik Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.195-201
    • /
    • 2016
  • Eddy current testing (ECT) is commonly applied for the inspection of automated production lines of metallic products, because it has a high inspection speed and a reasonable price. When ECT is applied for the inspection of a metallic object having an uneven target surface, such as the spline gear of a spline shaft, it is difficult to distinguish between the original signal obtained from the sensor and the signal generated by a defect because of the relatively large surface signals having similar frequency distributions. To facilitate the detection of defect signals from the spline gear, implementation of high-order filters is essential, so that the fault signals can be distinguished from the surrounding noise signals, and simultaneously, the pass-band of the filter can be adjusted according to the status of each production line and the object to be inspected. We will examine the infinite impulse filters (IIR filters) available for implementing an advanced filter for ECT, and attempt to detect the flaw signals through optimization of system design parameters for detecting the signals at the system level.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.