• Title/Summary/Keyword: 디지털방사선영상시스템

Search Result 109, Processing Time 0.027 seconds

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발

  • 김새롬;김희중;정해조;강원석;이재훈;이상호;신성범;유선국
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.81-81
    • /
    • 2003
  • 목적 : 현재, 많은 병원이 방사선과 의료영상정보를 기존의 필름형태로 판독하고, 진료하는 방식에서 PACS 를 도입하여 디지털 형태로 영상을 전송, 저장, 검색, 판독하는 환경으로 변화하고 있다. 한편, PACS 가 가지는 가장 큰 제한점은 휴대성의 결핍이다. 본 연구는 이동형 장치가 가지는 호스트의 이동성 및 휴대성의 장점들을 살리면서, 무선 채널 용량의 한계, 무선 링크 사용이라는 제약점들을 감안하여 의료영상을 JPEG2000 영상압축 방식으로 부호화한 후 무선 환경을 고려한 전송 패킷의 크기를 결정하고자 하였으며, 무선 통신 중 발생되는 패킷 손실에 대응하기 위한 자동 오류 수정 기능도 함께 구현하고자하였다. 방법 : Window 2000 운영체계에서 의료영상을 로드하고, 데이터베이스화하며, 저장하고, 다른 네트워크와 접속, 제어가 가능한 PC급 서버를 구축하였다. 영상데이터는 무선망을 통해 전송하기 때문에 가장 높은 압축비율을 지원하면서 에너지 밀도가 높은 JPEG2000 알고리즘을 사용하여 영상을 압축하였다. 또한, 무선망 사용으로 인한 패킷 손실에 대비하여, 영상을 JPEG2000 방식으로 부호화한 후 각 블록단위로 전송하였다. 결과 : PDA에서 JPEG2000 영상을 복호화 하는데 걸리는 시간은 256$\times$256 크기의 MR 뇌영상의 경우 바로 확인할 수 있었지만, 800$\times$790 크기의 CR 흉부 영상의 경우 약 5 초 정도의 시간이 걸렸다. CDMA 1X(Code Division Multiple Access 1st Generation) 모듈을 사용하여 영상을 전송하는 경우, 256 byte/see 정도에서는 안정된 전송 결과를 보여주었고, 1 Kbyte/see 정도의 전송의 경우 중간 중간에 패킷이 손실되는 결과를 관찰할 수 있었다. 반면 무선 랜의 경우 이보다 더 큰 패킷을 전송하더라도 문제점은 발견되지 않았다. 결론 : 현재의 PACS는 유선과 무선사이의 인터페이스의 부재로 인해 유무선 연동이 되지 못하고 있다. 따라서 이동형 JPEG2000 영상 뷰어는 PACS가 가지는 문제점인 휴대성을 보완하기 위하여 개발되었다. 또한 무선망이 가지는 데이터 손실에 대하여서도 허용할 수 있는 범위에서 재전송을 가능하게 함으로서 약한 연결성을 보완하였다. 본 JPEG2000 영상 뷰어 시스템은 기존 유선상의 PACS와 이동형 장치간에 유기적인 인터페이스 역할을 하리라 기대된다.

  • PDF

Computer-Aided Diagnosis for Pulmonary Tuberculosis using Texture Features Analysis in Digital Chest Radiography (질감분석을 이용한 폐결핵의 자동진단)

  • Kim, Dae-Hun;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Chang-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.11
    • /
    • pp.185-193
    • /
    • 2011
  • There is no exact standard of detecting pulmonary tuberculosis(TB) in digital image of simple chest radiography. In this study, I experimented on the principal components analysis(PCA) algorithm in the past and suggested six other parameters as identification of TB lesions. The purpose of this study was to develop and test computer aided diagnosis(detection) method for the detection and measurement of pulmonary abnormalities on digital chest radiography. It showed comparatively low recognition diagnosis rate using PCA method, however, six kinds of texture features parameters algorithm showed similar or higher diagnosis rates of pulmonary disease than that of the clinical radiologists. Proposed algorithms using computer-aided of texture analysis can distinguish between areas of abnormality in the chest digital images, differentiate lesions having pulmonary disease. The method could be useful tool for classifying and measuring chest lesions, it would play a major role in radiologist's diagnosis of disease so as to help in pre-reading diagnosis and prevention of pulmonary tuberculosis.

A Study on the Design of DICOM Integration Engine in the Ubiquitous Computing Environments (유비쿼터스 컴퓨팅 환경에서의 DICOM 설계에 대한 연구)

  • Im, In-Chul;Ha, An-Rye;Kim, Chang-Soo;Hwang, In-Chul;Ok, Chi-Sang
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.307-315
    • /
    • 2005
  • In the ubiquitous computing environments, ICT industries of current society are developed in enormous growth. Medicine or patients with mobile devices can access at any time, any place. The medical procedures at the patient bedside are out of the scope of current systems, which means that patient record and image data access during the medical visit or the execution, recording and confirmation of the medicine prescriptions, still do not enjoy computerized support. Today, the exchange of medical images and clinical information is well defined by DICOM and HL7 standards. The DICOM independent terminal equipment image access system was developed in which a DICOM Engine acts as the gateway between a PACS DB and user's terminal. Implementation system is compatible with most currently available Integration system models. This paper presents a software technology where the medical and nursing staff will be equipped with any device connected by wire and wireless to a central server that provides access to the electronic patient records and that will actively inform about tasks pending distribution. The prototype described in this article implements a medical images and structured reports server that makes the search and recovery of data stored in the DICOM standard possible.

  • PDF

Fabrication of Gd2O2S:Tb fine scintillator film and evaluation of image quality for resolution improvement of X-ray imaging based on CMOS (CMOS 기반 X선 영상의 해상력 향상을 위한 Gd2O2S:Tb 미세형광체 필름 제작 및 영상 질 평가)

  • Kang, Sang-Sik;Choi, Young-Zoon;Jung, Bong-Jae;No, Si-Cheul;Cho, Chan-Hoon;Yoon, In-Chan;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.283-287
    • /
    • 2011
  • In this study, fine $Gd_2O_2S$:Tb powder was synthesized by using a low temperature solution-combustion method for a high-resolution digital x-ray imaging detector. From the fabricated phosphor power, the fine scintillator films was fabricated by particle sedimentation method and was investigated the luminescent property. From the experimental results of relative light output as a function of terbium concentration, the highest luminescent efficiency has at 5 wt% Tb concentration, and luminescent intensity decreased rapidly according to quenching effect about higher Tb concentration. Also, the relative light output of $270{\mu}m$-$Gd_2O_2S$:Tb film has 2945 pC/$cm^2$/mR. And light intensity was saturated at higher film thickness. Finally, to evaluate an image acquisition performance of fabricated phosphor, images were obtained by using commercial CMOS sensor and measured the MTF, NPS, and DQE. DQE(0 lp/mm) of fine phosphor film has 37%. But, DQE improvement of fine phosphor film is possible by resolving problem of film fabrication process and has a significant potential in the application of digital radiation imaging system later.

Automatic Detection of Initial Positions for Mass Segmentation in Digital Mammograms (디지털 마모그램에서 Mass형 유방암 분할을 위한 초기 위치 자동 검출)

  • Lee, Bong-Ryul;Lee, Myeong-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.5
    • /
    • pp.702-709
    • /
    • 2010
  • The performance of mass segmentation is greatly influenced by an initial position of a mass. Some researchers performed mass segmentation with the initial position of a mass given by radiologists. The purpose of our research is to find the initial position for mass segmentation and to notify the segmented mass to radiologists without any additional information on mammograms. The proposed system consists of breast segmentation by region growing and opening operations, decision of an initial seed with characteristics of masses, and mass segmentation by a level set segmentation. A seed for mass segmentation is set based on mass scoring measure calculated by block-based variances and masked information in a sub-sampled mammogram. We used a DDSM database to evaluate the system. The accuracy of mass detection is 78% sensitivity at 4 FP/image, and it reached 92% if multiple views for masses were considered.

The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions (의료정보 표준에 관한 연구 : 표준화 분석 및 전망)

  • Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  • PDF

Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography (유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가)

  • Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report (3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례)

  • Kang, Se-Ha;Jeong, Seung-Mi;Shin, Jae-Ok;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.158-168
    • /
    • 2015
  • This article describes how to use digital system in a fully edentulous case that diagnosis to definitive prosthesis fabrication. While proceeding oral scan and CBCT taking, digital markers were attached on maxillary palate and lower existing denture. Using CBCT image and oral scan image, the bone contour and anatomical structures were analyzed and flapless surgical guide, customized abutment and prosthesis were made. After the osseointegration, the definitive prosthesis was fabricated using the oral scan image with scan body. It provides clinicians with a fast workflow and improves clinical efficiency.

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.