• Title/Summary/Keyword: 디지털구강스캐너

Search Result 52, Processing Time 0.035 seconds

A Convergence Study on the Changes of Awareness and Preference according to the Clinical Application Experience of Digital Intraoral Scanners in Dental Hygienists (디지털 구강스캐너 임상적용 경험에 따른 치과위생사의 인지도 및 선호도 변화에 관한 융합연구)

  • Jang, Kyeung-Ae;Heo, Seong-Eun;Kang, Hyun-Kyung;Lee, Sook-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.135-140
    • /
    • 2018
  • This study aimed to determine the changes of awareness and preference of dental hygienists according to the experience of using a digital intraoral scanner through a convergence study. Data collected by an online survey for dental hygienists in Busan, Gyeongnam and Gyeongbuk were analyzed by SPSS 24.0 program. When dental hygienists had an experience of using a digital intraoral scanner, the awareness and preference of digital intraoral scanners were significantly higher. The experience of using a digital intraoral scanner showed a positive correlation with the clinical application experience of digital intraoral scanners; the clinical application experience of digital intraoral scanners, with the awareness of digital intraoral scanners; and the awareness of digital intraoral scanners, with the preference of digital intraoral scanners. In conclusion, the dental hygienist's experience in clinical application of digital intraoral scanners is expected to increase the awareness and preference, resulting in the improvement of dental hygienists' work ability. Therefore, it is believed that continuous education and learning about digital oral scanners are needed.

Dental hygienists' Needs for Convergence Education according to the Use of Digital Intraoral Scanners (치과위생사의 디지털 구강스캐너 사용에 따른 융합적 교육 요구도)

  • Kang, Hyun-Kyung;Lee, Sook-Jeong;Jang, Kyeung-Ae;Heo, Seong-Eun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.5
    • /
    • pp.69-75
    • /
    • 2018
  • The purpose of this study was to investigate the systematic and convergent education needs according to the use of digital intraoral scanners in dental hygienists. Data of 127 respondents who participated in an online survey for dental hygienists working at dental hospitals and clinics were analyzed by the frequency analysis, t-test, one way ANOVA, and correlation using SPSS 24.0 program. The utilization period of digital intraoral scanners in the hospital was 'less than 1 year' in 78.7%. As for relevant education experience, 58.3% answered 'no', showing a higher proportion of no education experience. As for clinical application of digital intraoral scanners, 77.4% responded that they use the scanner for clinical purposes. With regard to digital intraoral scanner education, 61.4% responded that education is necessary. This result reflects the fact that digital intraoral scanners have been rapidly introduced to dental hospitals and clinics, but systematic education has not been given. Therefore, we hope that this paper will be used as basic data to recognize the need for education on digital intraoral scanners.

Review of recent developments for intra-oral scanners (현재 존재하는 구강 스캐너에 대한 고찰)

  • Choi, Jong-Hoon;Lim, Young-Jun;Lee, Won-Jin;Han, Jung-Suk;Lee, Seung-Pyo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.112-125
    • /
    • 2015
  • Making a model that is an accurate replica of the oral structure requires precision and efficiency. Nowadays, rapid technological advances bring digitalization in dentistry. One of the most important works in digital dentistry is three-dimensional modeling of the oral cavity and digitizing the 3D data. Among the three components of CAD/CAM, (1) data capture component (digitizers), (2) design component (CAD software), (3) manufacturing component (CAM), the basic component that has a significant impact on the other processes is the data capture component, i.e. intra-oral scanners. This literature review discusses the principles and clinical use of intra-oral scanners in dentistry based on recent publications of the past 5 years using the PubMed and Google Scholar databases.

Evaluation of the accuracy of three different intraoral scanners for endocrown digital impression: An in vitro study (엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구)

  • Ural, Cagri;Park, Ji-Man;Kaleli, Necati;Caglayan, Esma
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.282-289
    • /
    • 2020
  • Purpose: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (IOSs) on digital impressions of different types of endocrown cavity preparations. Materials and methods: Two human mandibular molar teeth were prepared with different endocrown abutment designs: one with a buccal wall (Class 2) and the other without a buccal wall (Class 3). Both cavity designs were scanned using a reference desktop scanner (E3) and three different intraoral scanners: Trios3 (TRI group), Cerec Omnicam (CER group), and i500 (I5 group). The obtained Standard Tessellation Language (.stl) datasets were exported to metrology software. The precision was evaluated based on deviations among repeated scan models recorded by each IOS. The trueness was evaluated based on deviations between the reference data and repeated scans. For detecting interaction, data were statistically analyzed using a univariate analysis of variance (ANOVA) and for analyzing the comparison of the test groups data were analyzed by one-way ANOVA and post-hoc Tukey test at the significance level of .05. Results: The deviation values for both cavity designs in the I5 group were significantly lower than those in the other IOS groups in terms of trueness. For both cavity designs, the TRI group exhibited better precision than the other IOS groups. Conclusion: Different technologies of IOS device's and different endocrown prepration designs affected the accuracy of the digital scans.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

A case report of single crown restoration using an intraoral scanner for occlusal evaluation (단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고)

  • Song, Jun-Beom;Lee, Jong-Hyuk;Ha, Seung-Ryong;Choi, Yu-Sung;Choi, Sun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.341-349
    • /
    • 2021
  • The evaluation of occlusion using digital methods is easier and simpler in terms of recording, comparison, analysis, and objectivity compared to existing methods such as articulating paper and occlusion foil. The purpose of this case report was utilizing the digital method for evaluating occlusion. The occlusion of patient requiring full veneer crown restoration was evaluated using an intraoral scanner (i500, Medit, Seoul, Korea) at every visit. The occlusion was also assessed using conventional articulating paper and a digital occlusal analysis system (Dental prescale II, GC corp., Tokyo, Japan) for comparison. Throughout the treatment process, the intraoral scanner and the conventional articulating paper method showed similar outcomes. The results suggest that the use of digital evaluation system is highly probable in the near future.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

Fabrication of removable partial denture on scleroderma patient using 3-dimensional intraoral scanner (전신성 피부경화증 환자에서의 3차원 구강스캐너를 이용한 가철성 국소의치 제작 증례)

  • Kim, Ung-Gyu;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.116-125
    • /
    • 2021
  • A three-dimensional (3D) intraoral scanner, which is one of the major developments in digital dentistry, is widely used in fixed prosthodontics. The application of intraoral scanner is now increasing in removable prosthodontics. Sclerotic change induced by scleroderma causes the limitation of mouth opening and multiple loss of the teeth. Conventional prosthodontic procedures are challenging for patients with this disease. This study showed a case of digital approach to the removable prosthodontic treatment of a patient who had the scleroderma and the consequent microstomia. At the provisional stage, the optical impression of patient's oral structures was digitally obtained. Using a 3D printer, the provisional dentures were fabricated. After extraction of hopeless tooth, the definitive digital impression was taken and the metal frameworks were fabricated, based on the data acquired from the impression. The definitive removable partial dentures were completed and delivered to the patient, who was satisfied with the prostheses.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation (치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구)

  • Park, Ju-Hee;Seol, Jeong-Hwan;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.104-115
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the image acquisition ability of intraoral scanners by analyzing the comprehensiveness of scanned images from standardized model, and to identify problems of the model. Materials and Methods: Cast models and 3D-printed models were prepared according to international standards set by ISO12836 and ANSI/ADA no. 132, which were then scanned by model scanner and two different intraoral scanners (TRIOS3 and CS3500). The image acquisition performance of the scanners was classified into three grades, and the study was repeated with varying surface conditions of the models. Results: Model scanner produced the most accurate images in all models. Meanwhile, CS3500 showed good image reproducibility for angled structures and TRIOS3 showed good image reproducibility for rounded structures. As for model ingredients, improved plaster model best reproduced scan images regardless of the type of scanner used. When limited to 3D-printed model, powdered surface condition resulted in higher image quality. Conclusion: When scanning structures beyond FOV (field of view) in standardized models (following ISO12836 and ANSI/ADA 132), lack of reference points to help distinguish different faces confuses the scanning and matching process, resulting in inaccurate display of images. These results imply the need to develop a new standard model not confined to simple pattern repetition and symmetric structure.