• Title/Summary/Keyword: 등온화 용기

Search Result 5, Processing Time 0.021 seconds

Effect of Stabilizing Thermal Gradients on Natural Convection in a Completely Confined Rectangular Enclosure (안정온도구배가 밀폐용기내의 자연대류에 미치는 영향)

  • 김무현;이진호;장은구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.6
    • /
    • pp.1330-1338
    • /
    • 1989
  • 본 연구에서는 직각밀폐용기의 수평경계면이 단열인 경우뿐만 아니라 등온 조건을 갖는 경우에 대해 실험적으로 연구하여 경계조건의 변화가 직각밀폐용기내 흐름 및 열전달에 미치는 영향, 특히 등온조건을 갖는 경우 수직 온도차에 따르는 안정온도 구배효과로 예상되는 흐름의 억제, 지연효과를 작종 물리적 변수들의 영향과 함께 세밀히 조사하였다.

Characteristics Measurement of Pneumatic Elements Using Isothermal Chamber (등온화용기를 이용한 공기압 기기의 성능계측)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • In this study, methods for the characteristics measurement of pneumatic elements using isothermal chamber, the methods for the flow rate and dynamic characteristic measurement of pneumatic control valve, are proposed. An isothermal chamber is a chamber in which the steel wool is stuffed and isothermal condition can almost be realized. Therefore, the instantaneous flow rate could be measured only from the pressure response using the state equation of gas. Effectiveness and simplicity of the proposed method are confirmed by comparing the measured results obtained by proposed methods with the methods defined JIS and the ISO standards.

  • PDF

A Study on the Measurement Method of Leakage for Pneumatic Cylinder (공기압실린더의 누설유량 계측에 관한 연구)

  • Jang, J.S.;Ji, S.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder (공압실린더의 누설유량 계측방법에 관한 연구)

  • Jang J.S.;Ji S.W.;Jeong J.H.;Kang B.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid (압축성유체 유량계측장치 설계 및 제작)

  • Ji, S.W.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.