• Title/Summary/Keyword: 등방재

Search Result 1,554, Processing Time 0.026 seconds

Urban Runoff According to Rainfall Observation Locations (강우 측정 지점에 따른 도시 유역 유출량 변화 분석)

  • Hyun, Jung Hoon;Chung, Gunhui
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.305-311
    • /
    • 2019
  • Recently, global climate change causes abnormal weather and disaster countermeasures do not provide sufficient defense and mitigation because they were established according to the historical climate condition. Repeated torrential rains, in particular, are causing damage even in the robust urban flood defense system. Therefore, in this study, the change of runoff considering the spatial distribution of rainfall and urban characteristics was analyzed. For rainfall concentrated in small catchment, rainfall in the watershed must be accurately measured. This study is based on the rainfall data observed with Automated Surface Observing System (ASOS) and Automatic Weather Stations (AWS) provided by the Seoul Meteorological Administration. Effluent from the pumping station was estimated using the EPA-SWMM model and compared and analyzed. Catchments with rainwater pumping station are small with large portion of impermeable areas. Thus, when the ASOS data where is located from from the chatchment, runoff is often calculated using rainfall data that is different from rainfall in the catchment. In this study, the difference between rainfall data observed in the AWS near the catchment and ASOS away from the catchment was calculated. It was found that accurate rainfall should be used to operate rainwater pumping stations or forecast urban flooding floods. In addition, the results of this study may be helpful for estimating design rainfall and runoff calculation.

Estimation of Daily Sewage and Direct Runoff for the Combined Sewer System of Gunja Experimental Drainage (군자 시험배수구역 합류식 하수관거시스템의 일일하수량 및 직접유출량 산정)

  • Kim, Chung-Soo;Han, Myoung-Sun;Kim, Hyoung-Seop
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • A localized torrential rainfall and flash floods which are more frequently occurred by extraordinary atmospheric phenomena and rising sea surface temperature require more hydrological data collecting and analysis for small watershed. Urban watershed hydrological data monitoring system is needed because of big flood potential damage and lack of urban watershed hydrological data. Therefore, Urban Flood Disaster Management Research Center operates small experimental catchments(Sinnae1, Gunja, and Children's Park) observing and analyzing hydrological data(rainfall, stage, and discharge). In this study, the discharge of combined sewage for Gunja experimental drainage is analyzed with weekly data and day of the week data. Through several analyses in analyzing the urban runoff characteristics and managing the urban sewage system, direct runoff is calibrated and verified by the estimated values of rainfall-runoff model(SWMM).

Regional Assessment of Seismic Site Effects and Induced Vulnerable Area in Gyeonggi-do, South Korea, Using GIS (GIS 기반 경기도 광역영역의 부지지진응답 특성 및 연계 지진 취약지역 분석)

  • Kim, Han-Saem;Sun, Chang-Guk;Cho, Hyung-Ik;Nam, Jee-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.5
    • /
    • pp.19-35
    • /
    • 2018
  • The necessity of predicting the spatial information of the site-specific seismic response, which is essential information for the comprehensive earthquake disaster countermeasures, is increasing for the mid-west urban areas where the earthquake-induced damages can be increased due to frequent occurrence of mid-scale earthquake such as 2016 Gyeongju Earthquake and 2017 Pohang Earthquake. Especially, researches on strategic securing of site survey datasets and understanding the site-specific site response characteristics were conducted for Gyeonggi-do, South Korea. In this study, a GIS-based framework for site-specific assessment of site response and induced vulnerable area in Gyeonggi-do, South Korea was proposed. Geo-Data based on GIS platform was constructed for regional estimation of geotechnical characteristics by collecting borehole and land coverage datasets. And the geo-spatial grid information was developed for deriving spatial distribution of geotechnical layer and site response parameters based on the optimization of the geostatistical interpolation method. Accordingly, base information for Improving earthquake preparedness measures was derived as seismic zonation map with administrative sub-units considering the quantitative site effect of Gyeonggi-do.

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses (공동주택 화재감지 및 소화성능개선에 관한 연구)

  • Lee, Chae-Won;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study suggested the problems and their improvement measures for the operation of fire detectors and sprinkler heads installed at apartment houses. According to a census on population and housing in 2010, apartment houses account for 71.6% of the total housing facilities. And by fire statistics data of the National Emergency Management Agency, approximately 25.0% of fire accidents and 46.4% of casualties occur at apartment houses every year. Therefore, this study conducted for identifying the causes and characteristics of fire to establish the fire safety improvement measures for apartment houses. And this study was carried out virtual fire simulation at domestic apartment houses. The scenario of the simulation contains a comparative analysis on the operation time of standard sprinkler heads and residential sprinkler heads, heat detectors and smoke detectors. As a result of simulation, it was found that standard sprinkler heads and heat detectors installed at the existing apartment houses should be replaced with residential sprinkler heads and smoke detectors for rapid fire suppression. In addition, sprinkler systems should be considered to be installed for excluded floor at apartment houses. Especially, it is necessary to construct remote inspect systems like advanced countries for efficiency of apartment houses safety management.

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

Analysis of Agricultural Reservoir Drought Reaction Capability Followed by Precipitation Change of Non-irrigation Period (비관개기 강수량 변화에 따른 농업용저수지의 미래 가뭄 대응 능력 분석)

  • Bang, Je-Hong;Lee, Sang-Hyun;Lee, Sung-Hack;Choi, Jin-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.538-538
    • /
    • 2015
  • 농업가뭄에 대한 연구는 주로 가뭄지표의 개선과 제안 등에 초점이 맞추어져 있으며 관개기의 강수량에 중점을 둔 사례가 대부분이다. 그러나 대부분의 논 관개용수는 저수지를 통하여 공급되기 때문에 관개가 시작되는 4월 초순의 저수량은 상당히 중요한 가뭄 대응 요소이다. 이에 따라 가뭄에 대비하기 위해서는 관개가 종료되는 10월부터 이듬해 3월까지 충분한 저수량이 확보될 필요가 있다. 그러나 기후변화에 의해 대부분의 강우가 관개기에 집중될 수 있으며 이에 따라 미래에는 비관개기 동안 충분한 저수량을 확보하는데 어려움이 발생할 수 있다. 이에 본 연구에서는 기후변화에 따른 비관개기의 강수량을 확률기반으로 분석하고, 이를 관개기 필요저수량과 비교하여 저수지의 미래 가뭄 대응 능력을 분석하고자 하였다. 기후변화에 따른 비관개기의 강수량 변화를 분석하기 위하여 RCP(Representative Concentration Pathways) 시나리오를 적용하여 미래 비관개기 동안의 연도별 비관개기 누적강수량을 분석하였다. 과거와 미래시기를 30년 단위로 구분하여 1995s, 2025s, 2055s, 2085s의 비관개기 동안의 비초과확률 10%, 50%, 90%의 강수량을 분석하였다. RCP 4.5 시나리오를 기반으로 모의한 미래강우의 비초과확률 10% 누적강수량 산정 결과에 따르면 주요 곡창지대인 전라남북도는 1995s에는 10월부터 이듬해 3월까지의 누적강수량이 약 215mm 정도로 나타났으나 2025s에는 약 150mm로 줄어드는 것으로 나타났다. 즉, 비초과확률 10%의 강우가 내릴 경우 비관개기 동안에 충분한 저수량의 확보가 어렵게 되고 관개기의 심각한 가뭄을 초래할 수 있었다. 비관개기 누적강수량과 저수량변화의 관개를 모의한 개운저수지와 계룡저수지의 경우 그 관계식은 y=1.442x-198.81, y=5.8105x-752.92와 같이 나타났다. y는 비관개기의 저수량변화를 나타낸 것이고 x는 비관개기의 누적강우량을 나타낸 것이다. 식을 통해 향후 100년 중 비초과확률 10%의 강수를 가정한다면 개운저수지는 관개종료시점의 저수율이 최소 96.93% 이상이여야 다음해 관개시작시점의 저수위가 만수위가 될 수 있었고, 계룡 저수지는 최소 86.84%의 저수위를 만족해야 다음해 관개시작시점의 저수위가 만수위가 될 수 있었다.

  • PDF

A study on the development of quality control algorithm for internet of things (IoT) urban weather observed data based on machine learning (머신러닝기반의 사물인터넷 도시기상 관측자료 품질검사 알고리즘 개발에 관한 연구)

  • Lee, Seung Woon;Jung, Seung Kwon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1071-1081
    • /
    • 2021
  • In addition to the current quality control procedures for the weather observation performed by the Korea Meteorological Administration (KMA), this study proposes quality inspection standards for Internet of Things (IoT) urban weather observed data based on machine learning that can be used in smart cities of the future. To this end, in order to confirm whether the standards currently set based on ASOS (Automated Synoptic Observing System) and AWS (Automatic Weather System) are suitable for urban weather, usability was verified based on SKT AWS data installed in Seoul, and a machine learning-based quality control algorithm was finally proposed in consideration of the IoT's own data's features. As for the quality control algorithm, missing value test, value pattern test, sufficient data test, statistical range abnormality test, time value abnormality test, spatial value abnormality test were performed first. After that, physical limit test, stage test, climate range test, and internal consistency test, which are QC for suggested by the KMA, were performed. To verify the proposed algorithm, it was applied to the actual IoT urban weather observed data to the weather station located in Songdo, Incheon. Through this, it is possible to identify defects that IoT devices can have that could not be identified by the existing KMA's QC and a quality control algorithm for IoT weather observation devices to be installed in smart cities of future is proposed.

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

An Empirical Study on Firefighters' Health Hazard Factors -Focused on Fire Fighters, Rescue Workers and Emergency Medical Technicians Perception in Busan Fire Fighters- (소방공무원 건강장해 유해인자에 대한 실증연구 -화재진압대원, 구조대원, 구급대원의 인식조사를 중심으로-)

  • Kwon, Seol A;Lee, Min-Kyu;Park, Sang Ho;Kim, Da Young;Ryu, Sang Il
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.520-529
    • /
    • 2019
  • This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. Moreover, the danger of shift work was perceived the most by paramedics. This corresponds to the existing studies arguing that shift work is harmful to health. Next, the overload of patient transport was recognized as the second biggest hazard factor. This demonstrates they are worried about various second accidents that may happen due to a lot of patient transport works. In addition, the possibility of causing a traffic accident was perceived as a hazard factor too, since they must drive ambulance cars quickly to transport patients. Lastly, rescue workers regarded these hazard factors to be most dangerous. This is associated with their occupational characteristics, because rescue workers are the closest to diverse risks including a fire.