• Title/Summary/Keyword: 등가유전율

Search Result 29, Processing Time 0.04 seconds

Simplified Design Methodology for Frequency Filtering Hybrid Composites (주파수 필터링 하이브리드 복합재의 단순화된 설계 방법)

  • Kim, Yoon Jae;Baek, Sang Min;Oh, Won Seok;Go, Jeong In
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.897-903
    • /
    • 2019
  • This paper represents an simplified design method of hybrid composites. The proposed method is very simple compared to conventional design approaches and easy to apply to practical design problems. The method is based on not complex optimization approaches but conventional theories. The equivalent dielectric properties concept and multi-layered dielectric slab theory are an important theoretical background of the proposed method. This approach divide the design domain into several domain which have theoretically different electro- agnetic functionality. Then, the domains are expressed by equivalent dielectric properties. Numerical analysis are performed several types of design candidates. S-parameter test for final design was conducted for validate the proposed approach indirectly.

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1287-1288
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe를 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2253-2254
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe클 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.621-622
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe를 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Two-port probe for measuring the permittivity/permeability (유전율/투자율 측정을 위한 2-PORT PROBE)

  • Park, Sang-Bok;Lee, Jang-Soo;Cheon, Chang-Ul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1747-1748
    • /
    • 2006
  • 본 연구에서는 2-port probe를 설계, 제작하고, 이를 이용하여 유전율과 투자율을 동시에 측정해내는 기법을 연구하였다. 기존에는 유전율 측정을 위해 끝이 open되어 있는 1-port probe를 주로 이용하였지만 이는 유전율만이 측정이 가능하고 주파수 대역에 한계가 있었다. 2-port probe는 유전율과 투자율이 동시에 측정이 가능하며 주파수의 한계를 극복하였다. 2-port probe를 등가화 하여 이를 수식적으로 해석했을 경우 수많은 변수들이 발생되는데 이것을 여러 수치기법들을 이용하여 정리한 후, 유전율을 알고 있는 용액들을 이용하여 보정하였다. 또한 2-port probe에 약간의 길이 변화를 주어 주파수대역의 변화를 실험을 통해 비교 분석하였다.

  • PDF

Theoretical Characteristics of the Probe with Respect to the Engine Oil States (엔진오일 상태에 대한 프로브의 이론 특성)

  • Kim, Young-Ju
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.1
    • /
    • pp.22-24
    • /
    • 2012
  • Depending on the status of the engine oil, the dielectric constant is changed. Dielectric constant of oil is related to the characteristic impedance of the probe and the characteristic impedance of the probe determines the reflected signal. In this paper, we derive an equivalent circuit of the probe and using the dielectric constant obtained by measuring the capacitance, the theoretical reflection coefficient of the probe was calculated. In the results, if the engine oil is deteriorated, we can see that the reflection coefficient is increased.

A Study on the High Frequency Characteristics and Equivalent Circuit Model of Microstrip Lines Having Defected Ground Structures in Multilayer Substrates (다층기판으로 구현된 마이크로스트립 선로와 결함접지구조의 초고주파 특성 및 등가회로 모델링)

  • Oh, Seong-Min;Koo, Jae-Jin;Park, Chun-Sun;Hwang, Mun-Su;Ahn, Dal;Lim, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1106-1115
    • /
    • 2006
  • In this paper, the transmission characteristics and equivalent circuit model of microstrip transmission line having defected ground structure (DGS) in multilayer substrates are described fur high frequency region. In order to perform the study, the second dielectric layer is attached additionally onto the bottom(ground) plane of the basic DGS microstrip line consisted of the microstrip line and DGS. The dielectric constant and thickness of the second dielectric layer are adjusted to get various transmission characteristics and model parameters, and to analysis the effect of the second dielectric layer ultimately. According to this paper, the effect and equivalent circuits due to the attached dielectric substrate are verified separately, and this is expected to be applied to high frequency circuit design in the future.

  • PDF

Retrieval of Soil Moisture Using Microwave Reflection at the End of a Coaxial Probe (동축선 끝단에서의 마이크로파 반사를 이용한 토양 수분 함유량 산출 기술)

  • 김태진;오이석
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.151-163
    • /
    • 1997
  • In this paper, an algorithm for retrieving soil moisture from measurement of microwave reflection at the end of a coaxial canble is presented. Because the wave reflection from the boundary between air and soil layers depends on the dielectric constant of the soil layer, the dielectric constant can be obtained from measured reflection coefficient. At first, an equivalent circuit for the coaxial probe contaced on the soil surface was chosen with two unknown circuit elements. Then, the unknown circuit elements are obtained experrmentally by measuring the reflection constants of 20 soil samples, and consequently, an empirical formula for computing the dielectric constant from the reflection coefficient is obtained. The dielectric constant is mainly influenced by the soil moisture, and the soil moisture can be computed from the dielecfic constant using an existing empirical formula. HP Network Analyzer 8510C was used to measure the magnitude and the phase of the reflection coeffcient at 4.65 GHz, and the measured data set were used to obtain an empirical formula for computing the dielectric constant. The empirical formula obtained in this study was proven by other soil samples.

TM Wave Scattering by the Perfectly Conducting Strip Loaded with a Dielectric Cylinder (유전체실린더로 둘러 싸인 완전 도체스트립에 의한 TM파의 산란)

  • Kim, Nam-Tae;Lee, Sang-Seol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.3
    • /
    • pp.7-12
    • /
    • 1990
  • A rigorous analysis of the scattering problem by the perfectly conducting strip loaded with a dielectric cylinder of different permittivity is presented. By introducing auxiliary electromagnetic fields and applying the reciprocity theorem, integral equations for the unknown electric field are derived. These integral equations are transformed into an equivalent matrix equation of infinite order with proper boundary conditions. By calculating inverse matrix of unknown coefficients from this equation, scattered electric fields are determined. In particular case of the dielectric with the same permittivity, the results of this paper correspond to well-known results.

  • PDF

A Study on the Errors for the Improved Version of the Virtual Transmission-Line Model (개선된 가상의 전송선로 모델의 오차 연구)

  • 조유선;김세윤;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.971-981
    • /
    • 2002
  • An open-ended coaxial probe method has been considered as one of effective tools for measuring electrical properties of its contacted material without shaping and fitting. The measured reflection coefficient at the probe's end is able to convert into the corresponding complex permittivity by employing the improved version of virtual transmission-line model Presented by our lab already. But the error of complex permittivity converted by equivalent model increases as the operating frequency ascends high. The errors of complex permittivity in the open-ended coaxial probe can be yielded compositively by the imperfect contact or probe, manufacture error of probe and complex permittivity error of reference material etc. Therefore it is necessary to limit the problem to identify the error causes in high frequency. In this paper, the errors which are resulted from the measurement of reflection coefficient are removed by using the FDTD(Finite-Difference Time-Domain) method, the error causes are limited the conversion model problem. And the error study of the improved conversion model is performed from several viewpoints. At first, the local minimum of parameter to be calculated by the iteration method in the conversion model is checked. At second, the modeling of the equivalent model is checked in the frequency range. From this study, we know the valid range of the improved conversion model.