• Title/Summary/Keyword: 두 경계방법

Search Result 611, Processing Time 0.033 seconds

Semi-supervised learning for sentiment analysis in mass social media (대용량 소셜 미디어 감성분석을 위한 반감독 학습 기법)

  • Hong, Sola;Chung, Yeounoh;Lee, Jee-Hyong
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.482-488
    • /
    • 2014
  • This paper aims to analyze user's emotion automatically by analyzing Twitter, a representative social network service (SNS). In order to create sentiment analysis models by using machine learning techniques, sentiment labels that represent positive/negative emotions are required. However it is very expensive to obtain sentiment labels of tweets. So, in this paper, we propose a sentiment analysis model by using self-training technique in order to utilize "data without sentiment labels" as well as "data with sentiment labels". Self-training technique is that labels of "data without sentiment labels" is determined by utilizing "data with sentiment labels", and then updates models using together with "data with sentiment labels" and newly labeled data. This technique improves the sentiment analysis performance gradually. However, it has a problem that misclassifications of unlabeled data in an early stage affect the model updating through the whole learning process because labels of unlabeled data never changes once those are determined. Thus, labels of "data without sentiment labels" needs to be carefully determined. In this paper, in order to get high performance using self-training technique, we propose 3 policies for updating "data with sentiment labels" and conduct a comparative analysis. The first policy is to select data of which confidence is higher than a given threshold among newly labeled data. The second policy is to choose the same number of the positive and negative data in the newly labeled data in order to avoid the imbalanced class learning problem. The third policy is to choose newly labeled data less than a given maximum number in order to avoid the updates of large amount of data at a time for gradual model updates. Experiments are conducted using Stanford data set and the data set is classified into positive and negative. As a result, the learned model has a high performance than the learned models by using "data with sentiment labels" only and the self-training with a regular model update policy.

MRI Findings of Triple Negative Breast Cancer: A Comparison with Non-Triple Negative Breast Cancer (삼중음성 유방암의 자기공명영상 소견: 비삼중음성 유방암과의 비교)

  • Choi, Jae-Jeong;Kim, Sung-Hun;Cha, Eun-Suk;Kang, Bong-Joo;Lee, Ji-Hye;Lee, So-Yeon;Jeong, Seung-Hee;Yim, Hyeon-Woo;Song, Byung-Joo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.2
    • /
    • pp.95-102
    • /
    • 2010
  • Purpose : To evaluate the magnetic resonance imaging (MRI) and clinicopathological features of triple negative breast cancer, and compare them with those of non-triple negative breast cancer. Materials and Methods : This study included 231 pathologically confirmed breast cancers from January 2007 to May 2008. We retrospectively reviewed the MRI findings according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon: mass or non-mass type, mass shape, mass margin, non-mass distribution, and enhancement pattern. Histologic type, histologic grade, and the results for epidermal growth factor receptor, p53, and Ki 67 were reviewed. Results : Of 231 patients, 43(18.6%) were triple negative breast cancer. Forty triple negative breast cancers (93.0%) were mass-type lesion on MRI. A round or oval or lobular shape (p=0.006) and rim enhancement (p=0.004) were significantly more in triple negative breast cancer than non- triple negative breast cancer. In contrast, irregular shape (p=0.006) and spiculated margins (p=0.032) were significantly more in non-triple negative breast cancer. Old age (p=0.019), high histologic grade (p<0.0001), EGFR positivity (p<0.0001), p53 overexpression (p=0.038), and Ki 67 expression (<0.0001) were significantly associated with the triple negative breast cancer. Conclusion : MRI finding may be helpful for differentiation between triple negative and non-triple negative breast cancer.

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.

EXPRESSION PATTERN OF RUNX2 IN MURINE TOOTH DEVELOPMENT (Mouse의 치아 발육시 Runx2의 발현 양상)

  • Kim, Tae-Wan;Ryoo, Hyun-Mo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.651-658
    • /
    • 2004
  • Runx2 is a transcription factor in homologous with Drosophila runt gene and it is essential for bone formation during embryogenesis and a critical gene for osteoblast differentiation and osteoblast function. Runx2-haploinsufficency causes cleidocranial dysplasia (CCD). CCD is an autosomal-dominant inherited disorder characterized by hypoplastic clevicle and delayed ossification in fontanelles and wormian bones. Dental defects are possibly shown to CCD patients : multiple supernumerary teeth, irregular and compressed permanent tooth crowns, hypoplastic and hypomineralized defects in enamel and dentin, an excess of epithelial root remnants, the absence of cellular cementum, and abnormally shaped roots. In addition, delayed eruption of the secondary dentition is a constant finding. The aim of this study is to evaluate the role of Runx2 in the tooth development and eruption through analyzing the expression pattern of Runx2 by in situ hybridization during crown (late bell stage) and root formation of tooth, using postnatal day 1, 4, 7, 14 and 21 mice mandibular molar teeth. mRNA of Runx2-full length is expressed in dental follicle and surrounding tissue at postnatal day1 and 4. At postnatal day 7, it is expressed in ameloblasts of occlusal surface of enamel and bone area surrounding the tooth. In comparison with previous stage, at postnatal day 14, it is expressed in ameloblasts of proximal surface of enamel. At postnatal day 21 it's expression is observed only in bone area. mRNA of Runx2-typeII is not expressed. At postnatal day 1 and 7. At postnatal day 14 and 21, it's expression is observed in the bone area. In this study, we suggest that Runx2 have a relation of ameloblasts differentiation and an important role to tooth eruption made by dental follicle during intraosseous eruption stage. Also we can confirm that Runx2 has a role to bone formation.

  • PDF

Psychology and Quality of Life in Cancer Patients on Radiation Therapy (방사선치료 중인 암 환자의 심리와 삶의 질)

  • Yang Jong-Chul;Chung Woong-Ki
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.271-279
    • /
    • 2004
  • Purpose: The object of this study Is to investigate sociodemographic and clinical characteristics, psychology, self-esteem and quality of life in cancer patients on radiation therapy and to provide useful information for therapeutic approach to cancer patients on radiation therapy. Materials and Methods: The subjects were 36 patents who had been treated with radiation therapy and 20 normal people. Sociodemographic information and clinical characteristics of cancer patients on radiation therapy were investigated, and symptom checklist-90-revised, Rosenberg Self-esteem Scale for self esteem, World Health Organization Quality of Life Assessment Instrument for quality of life were administered to subjects. And Spearman's correlation analysis was used among these. Result : The tendency of somatization, depression, anxiety and hostility in cancer group were significantly higher than normal group. Self esteem and quality of life in cancer group were significantly lower than normal group. No significant difference was found in comparison of psychology, self esteem and qualify on life according to sociodemographic variables. Among clinical characteristics, in the presence of metastasis in cancer patients, the scores of anxiety, phobia and paranoid ideation were higher In patients with pain, the score of somatization was higher And in case of weight loss, the score of somatization was higher. The higher score of depression, anxiety and hostility were significantly associated with lower self-esteem. And higher score of somatization, depression, anxiety and hostility were significantly associated with lower quality of life. Conclusion: Understanding and management of psychological symptoms, such as somatization, depression, anxiety, and hostility, and pain control are necessary to improve quality of life in cancer patients on radiation therapy.

The Zhouyi and Artificial Intelligence (『주역』과 인공지능)

  • Bang, In
    • Journal of Korean Philosophical Society
    • /
    • v.145
    • /
    • pp.91-117
    • /
    • 2018
  • This paper aims to clarify the similarities and differences between the Zhouyi and artificial intelligence. The divination of the Zhouyi is rooted in the oldest system of human knowledge, while artificial intelligence stands at the cutting edge of modern scientific revolution. At first sight, there does not appear to be any association that links the one to the another. However, they share the same ground as seen from a semiotic standpoint because both of them depend on the semiotic system as a means of obtaining knowledge. At least four aspects can be pointed out in terms of similarities. First, artificial intelligence and the Zhouyi use artificial language that consists of semiotic signs. Secondly, the principle that enables divination and artificial intelligence lies in imitation and representation. Thirdly, artificial intelligence and the Zhouyi carry out inferences based on mathematical algorithms that adopt the binary system. Fourth, artificial intelligence and the Zhouyi use analogy as a means of obtaining knowledge. However, those similarities do not guarantee that the Zhouyi could arrive at the scientific certainty. Nevertheless, it can give us important insight into the essence of our civilization. The Zhouyi uses intellect in order to get new information about the unknown world. However, it is hard to know what kind of intellect is involved in the process of divination. Likewise, we do not know the fundamental character of artificial intelligence. The intellect hidden in the unknown subject is a mystic and fearful existence to us. Just as the divination of the Zhouyi inspires the sense of reverence toward the supernatural subject, we could not but have fear in front of the invisible subject hidden in artificial intelligence. In the past, traditional philosophy acknowledged the existence of intellect only in conscious beings. Nonetheless, it becomes evident that human civilization ushers into a new epoch. As Ray Kurzweil mentioned, the moment of singularity comes when artificial intelligence surpasses human intelligence. In my viewpoint, the term of singularity can be used for denoting the critical point in which the human species enters into the new phase of civilization. To borrow the term of Shao Yong(邵雍) in the Northern Song Dynasty, the past civilization belongs to the Earlier Heaven(先天), the future civilization belongs to the Later Heaven(後天). Once our civilization passes over the critical point, it is impossible to go back into the past. The opening of the Later Heaven foretold by the religious thinkers in the late period of Joseon Dynasty was a prophecy in its own age, but it is becoming a reality in the present.

How the Information Location (up vs. down) Impacts Promotion Attractiveness and Amount Perception (판매촉진 정보의 위치(위vs.아래)가 판매촉진 매력도 및 증정량 지각에 미치는 영향)

  • Jang, JungMin;Kim, Yeong-Ju
    • (The) Korean Journal of Advertising
    • /
    • v.27 no.3
    • /
    • pp.7-25
    • /
    • 2016
  • According to recent studies, the location of visual information has a significant impact on consumers' interpretation and judgment in various contexts. In particular, vertical positioning is relevant to the perception of weight: consumers tend to interpret that products are heavier when information is placed at the bottom of a page or section rather than the top. This is due to the common perception that heavy things would sink to the bottom and light things would float up. Consistent with this research stream, the current study investigates how the vertical location of freebie information influences promotion evaluation. We hypothesize that consumers assume that the complimentary product is heavier when the information about it is displayed at the bottom compared to when the information is displayed at the top. Two experiments were conducted. In experiment 1, we show how the location of "get one free" information impacts the evaluation of the sales promotion in a "Buy two and get one free" context. When the complimentary information was displayed below rather than above the main product information, consumers evaluated the sales promotion more favorably. Experiment 2 tests the generalizability of the vertical location effect by using a different type of information and product: a visual picture of vitamin tablets rather than the numeric information as in Experiment 1. The dependent variable was also extended to the perceived amount of the promoted product. We suggest the boundary condition that the proposed effect is moderated by the presence or absence of an explicit message about the amount. Without an explicit message about the amount of the product, the results were similar to those of experiment 1 in that consumers perceived that the product offered a greater amount when the complimentary information was displayed at the bottom rather than at the top. However, the location effect disappeared with an explicit message about the amount. This confirms the moderating effect that presenting an explicit message about the amount is a crucial boundary condition for location effect in a value added promotion. Marketers can use this knowledge to formulate strategies in a variety of sales promotion conditions.

Tc-99m ECD Brain SPECT in MELAS Syndrome and Mitochondrial Myopathy: Comparison with MR findings (MELAS 증후군과 미토콘드리아 근육병에서의 Tc-99m ECD 뇌단일 광전자방출 전산화단층촬영 소견: 자기공명영상과의 비교)

  • Park, Sang-Joon;Ryu, Young-Hoon;Jeon, Tae-Joo;Kim, Jai-Keun;Nam, Ji-Eun;Yoon, Pyeong-Ho;Yoon, Choon-Sik;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.490-496
    • /
    • 1998
  • Purpose: We evaluated brain perfusion SPECT findings of MELAS syndrome and mitochondrial myopathy in correlation with MR imaging in search of specific imaging features. Materials and Methods: Subjects were five patients (four females and one male; age range, 1 to 25 year) who presented with repeated stroke-like episodes, seizures or developmental delay or asymptomatic but had elevated lactic acid in CSF and serum. Conventional non-contrast MR imaging and Tc-99m-ethyl cysteinate dimer (ECD) brain perfusion SPECT were Performed and imaging features were analyzed. Results: MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly in the parietal (4/5) and occipital lobes (4/5) and in the basal ganglia (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased perfusion in the corresponding regions of MRI lesions. In addition, there were perfusion defects in parietal (1 patient), temporal (2), and frontal (1) lobes and basal ganglia (1) and thalami (2). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion was noted in left parietal area and bilateral thalami. Conclusion: Tc-99m ECD SPECT imaging in patients with MELAS syndrome and mitochondrial myopathy showed hypoperfusion of parieto-occipital cortex, basal ganglia, thalamus and temporal cortex, which were not restricted to a specific vascular territory. There were no specific imaging features on SPECT. The significance of abnormal perfusion on SPECT without corresponding MR abnormalities needs to be evaluated further in larger number of patients.

  • PDF

Myocardial Tracer Uptake in SPECT Images after Direct Intracoronary Injection Of TI-201: Comparison with Stress-Reinjection Images (관동맥내 주사 TI-201 SPECT에서 심근 분절의 섭취: 부하-재주사 TI-201 영상과의 비교)

  • Seo, Ji-Hyoung;Kang, Seong-Min;Bae, Jin-Ho;Lee, Yong-Jin;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Cho, Yong-Geun;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.291-298
    • /
    • 2007
  • Purpose: To investigate the feasibility of TI-201 SPECT with intra coronary injection (lC-I) in the detection of viable myocardium, we have performed SPECT imaging after direct intracoronary injection of TI-201 and images were compared with those of stress-reinjection (Re-I) SPECT. Methods: Fourteen coronary artery disease patients (male 11, mean age 54 years) who had myocardial infarction or demonstrated left ventricular wall motion abnormality on echocardiography were enrolled. Three mCi of TI-201 was injected into both coronary arteries during angiography and images were acquired between 6- and 24-hour after injection. Reinjection imaging with 1 mCi of TI-201 was performed at 4-hour after adenosine stress imaging with 3 mCi of TI-201. Images were interpreted according to 4-grade visual scoring system (grade 0-3). Segments with mild to moderated uptake (${\leq}$grade 1), and upgraded more than one score with reinjection, and were defined as viable myocardium. Results: Image quality was poor in two cases with IC-I. Numbers of non-viable segments were 60 (23.8%) with IC-I, and 38 (15.1%) with Re-I, respectively. Overall agreement for perfusion grade per myocardial segment in each IC-I and Re-I was 76.5%. Overall agreement for viable segment between IC-I and Re-I was 90.5%. Only one out of 38 segments interpreted as non-viable with Re-I were interpretated as viable with IC-I. And 23 out of 214 segments interpreted as viable with Re-I were interpreted as non-viable with IC-I. Conclusion: Intracoronary TI-201 SPECT seemed to be not advantageous over stress-rest reinjection imaging in the assessment of myocardial viability, mainly due to low count statistics at 6-hour or 24-hour delayed time points. The feasibility of intracoronary TI- 201 SPECT is considered to be limited.

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF