• Title/Summary/Keyword: 동전기 정화

Search Result 43, Processing Time 0.031 seconds

Effect of Acid Buffering Capacity and Soil Component Remediation of Soil Contaminated with Phenanthrene using Electrokinetic-Fenton Process (산 완충능력과 토양 성분이 동전기-펜톤 공정에 의한 phenanthrene 오염토양 정화에 미치는 영향)

  • Kim, Jung Hwan;Na, So Jeong;Park, Joo Yang;Byun, Young Deog
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.129-136
    • /
    • 2013
  • This research was conducted to investigate effects of acid buffering capacity and soil component in treatment of phenanthrene using electrokinetic-Fenton process. In Hadong clay of high acid buffering and low iron oxide content, it was difficult to oxidize phenanthrene due to shortage of iron catalyst and scavenger effect of carbonate minerals. The desorbed phenanthrene conductive to Fenton oxidation was transported toward cathode by electroosmotic flow. However, in Youngdong illitic clay, oxidation of phenanthrene near anode readily occurred compared to Hadong clay due to high iron content and low acid buffering capacity.

The Remediation Characteristics of Natural Soil according to ElectroKinetic Remediation Systems under Unsaturated Conditions (불포화 자연토의 동전기 시스템에 따른 정화 특성)

  • Kim, Byung-Il;Kim, Ki-Nyun;Han, Sang-Jae;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.873-881
    • /
    • 2004
  • A serious of EK remediation tests on contaminated soil are performed under unsaturated conditions and analyzed for electrical potential, water content, pH and so on. The results indicated that electrical potential and pH distributions in the sample are dependent on the amount and inward/outward flow of hydrogen ion. Specially, for the closed system the water content is largely decreased with the flow of hydrogen. The maximum electrical conductivity is measured at the catholyte of CEM(Sealing) test and directly related to the remedial efficiency. Although pHs in the region near to the anode are similarly developed, the different concentration of lead is measured with the electrical gradient contrary to the lead concentration dependent on pH within the sample.

  • PDF

계면활성제와 동전기 기술을 이용한 오염토양정화에서 APG사용의 타당성에 관한 연구

  • 양지원;이유진;박지연;김상준
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.243-246
    • /
    • 2002
  • Surfactant-enhanced electrokinetic remediation is an emerging technology that can effectively remove hydrocarbons from low-permeability soils. In this study, the electrokinetic remediation using APG(alkyl polyglucoside) was conducted for the removal of phenanthrene from kaolinite. APG, which was an environmentally compatible and non-toxic surfactant, was used at concentrations of 5, 15, and 30g/1 to enhance the solubility of phenanthrene. Also an electrolyte solution was used for considering a relation between electrical potential gradient and removal efficiency of phenanthrene. When the electrolyte solution was used, it represented low electrical potential gradient, but the removal efficiency was lower than that of no electrolyte system. Removal efficiency of phenanthrene in EK process using surfactant solution depended on concentration of surfactant. Because surfactant increased the solubility and the mobility of phenanthrene, when surfactant concentration was high, high removal efficiency was observed.

  • PDF

중금속으로 오염된 사격장토의 동전기 정화 -실내 파일롯 실험 중심으로-

  • 한상재;김병일;이정철;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.69-72
    • /
    • 2003
  • The purpose of this study is the development of hybrid horizontal electrokinetic(EK) remediation system on rifle range soil under unsaturated conditions. In order to remediate soil polluted by multi-species heavy metals, in pi]of scale, a series of EK remediation tests are carried out. PVC and PDB(Plastic Drain Board) electrode systems that connected with the power supply of constant voltage and vacuum pressure of 0.5kgf/$\textrm{cm}^2$ are installed, The test results showed that the pH distribution in the sample is below 8, which is maintained until the test is finished, because of the injection of flushing solution. The final concentration, which is normalized by initial concentration, is ranged about 50 to 90%.

  • PDF

전압일정과 전류일정 조건에서의 동전기 정화 현상에 관한 해석

  • 김병일;김기년;이호진;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.203-206
    • /
    • 2004
  • To analysis the electrokinetic phenomena in the ground dependent on the way of applied electric power, such as constant current and constant voltage, the governing equations are derived considering advection, diffusion, ionmigration, and then they were formulated using by finite difference method. The developed program is verified by comparing the tested and predicted results reported in present papers. The results indicate that the slightly small electrical potential is predicted for constant current and for constant voltage pH near to the cathode was small than the test results. But the other predictions including the final suction, pH of electrolyte and cumulative flow are similar to the test results and predictions.

  • PDF

동전기-펜턴 토양정화공정에서 공정변수에 따른 분해성능 비교

  • 양지원;박지연;김상준;이유진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.239-242
    • /
    • 2002
  • Removal of phenanthrene by electrokinetic (EK) method combined with Fenton-like process was studied in a model system. Sand and phenanthrene were selected as a model soil and a representative PAH. Sand was contaminated at the concentration of 500 mg phenanthrene/kg dry sand. Bentonite and kaolinite were inserted into the space between reservoir and contaminated soil. When hydrogen peroxide supplied to a soil system from the anode reservoir was transported through the soil by EK process, the Fenton-like reaction was occurred by naturally existing iron minerals in soil. When hydrogen peroxide was supplied into the system, it showed higher removal efficiency than when just water was used. Maximum removal efficiency of phenanthrene was 81.2 % for 7 days.

  • PDF

아세트산의 농도에 따른 Ferrous Soil의 동전기 정화 거동

  • 이정철;김병일;조대호;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.306-309
    • /
    • 2003
  • The natural soil containing organic matter and ferrous is used in the Electrokinetic-Flushing Remediation(EFR) tests. A series of tests are carried out through controlling the concentration of acetic acid in the EFR cell. The test results showed that the electrical potential in X/L=0.9 is increased with the increasing of the concentration, and pH in the sample is the similar at all of the region because of the buffer capacity of natural soil. Finally, the efficiency of EFR is enhanced at acetic acid of 1mM. But it may not be not strongly affected by the concentration of acetic acid.

  • PDF

동전기-생물학적복원기술과 계면활성제를 이용한 phenanthrene 오염토양의 정화

  • 김상준;박지연;이유진;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.186-190
    • /
    • 2004
  • The electrokinetic bioremediation employing electrolyte circulation method was carried out for the cleanup of phenanthrene-contaminated kaolinite, and microorganism used in the biodegradation of phenanthrene was Sphingomonas sp. 3Y. The electrolyte circulation method supplied ionic nutrientsand the microorganism into soil, and inhibited the significant pH change of soil by increasing the soil buffering capacity by providing phosphate buffer compounds. When the remediation process was conducted without surfactant, the removal efficiency of phenanthrene, at the initial concentration of 200 ppm, was 69% for only 7 days. Higher microbial population and lower phenanthrene concentration were observed in the anode and middle regions of soil specimen than in the cathode region. The higher density of microorganism was because the microbial movement was in the direction of the anode part due to the negative surface charge. When Triton X-100 and APG of 20 g/1 were used to improve the bioavailability of phenanthrene strongly adsorbed onto soil surface, about 90 and 39% of phenanthrene removal were obtained. Consequently, it was confirmed that the microorganism preferred APC to phenanthrene as carbon source and so the removal efficiency with APG decreased less than that without APG.

  • PDF

Phenanthrene 오염토양의 정화를 위한 동전기-생물학적복원기술의 적용과 전류밀도의 영향

  • 김상준;박지연;이유진;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.181-185
    • /
    • 2004
  • Electrokinetic bioremediation was conducted on phenanthrene-contaminated soil to study the effects of soil temperature and pH on microbial population and removal efficiency at different current densities from 0.63 to 3.13 mA cm$^{-2}$ . Microorganism used in the biodegradation of phenanthrene was Sphingomonas sp. 3Y, which was isolated from a diesel-contaminated site. The microorganism was successfully penetrated into the contaminated soil by electrokinetic phenomena and the highest microbial population was observed in the middle region of soil specimen where soil pH was near neutral. Therefore, phenanthrene removal occurred mainly at anode and middle parts of soil specimen due to a relatively high microbial population. Also, the highest removal efficiency of 68.8% was obtained at 1.88 mA cm$^{-2}$ while low degradation was detected at 3.13 mA cm$^{-2}$ . It was presumably because the soil temperature at 1.88 mAcm$^{-2}$ was close to the appropriate temperature of about 30'c while the temperature increase to above 45$^{\circ}C$ at 3.13 mA cm$^{-2}$ inhibited the microbial activity severely.

  • PDF

Field application on bioelectrokinetic remediation of shooting range soil (생물학적으로 향상된 동전기 처리를 이용한 사격장 오염토양 정화 현장실증 연구)

  • Kwon, Young-Ho;Kim, Byeong-Kyu;Kim, Jeong-Rae;Kim, Jeong-Yeon;Oh, Hee-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1225-1230
    • /
    • 2010
  • 본 연구는 군부대 사격장의 중금속 오염토양에 대하여 생물학적 용출기술(BT)과 전기동력학적 기술(ET)의 통합공정의 적용성 평가 연구에 대한 것이다. 사격장 오염 토양의 경우 사격에 의해 탄두가 피탄지에 박히면서 오염토양 내에 잔존하여 탄두를 구성하는 주성분인 납과 구리 등에 의해 지속적인 오염원으로 작용하는 특징을 가진다. 따라서 사격장 토양오염정화를 위해서는 이 탄두를 물리적으로 선별하는 물리적 선별공정을 전처리공정으로 수행한 후 인공적으로 조성된 셀에 통합공정 적용성 평가를 위한 현장실증시험을 수행하였다. 생물학적 용출을 통해 토양내 잔류하는 중금속을 이온화시켜 이동성을 크게 한후 전기동력학적 기술을 통해 토양내에서 전해질로 이동시켜 최종적으로 전해질을 처리하는 시스템으로써 공정 모니터링결과 납과 구리 모두 주목할 만한 제거효율을 얻을수 있었다. 오염물질별 공정 적용성 평가결과 납의 경우 황산화박테리아에 의해 이온화가 되지만 황산화박테리아의 생장 부산물인 황산염이온(${SO_4}^{2-}$)과 반응하여 안정성이 큰 Anglesite($PbSO_4 $)를 형성하므로 전체적인 제거효율이 저하되는 것을 확인하였고 기타 미생물을 이용한 생물학적 용출기술 연구의 필요성을 확인하였다. 구리의 경우 황산염박테리아를 이용한 생물학적 용출공정 및 전기동력학적 처리공정의 통합공정을 통해 주목할 만한 제거효율을 얻을수 있었으며 통합공정의 효율성을 확인할 수 있었다. 본 연구를 통하여 미생물학적 용출기술과 전기동력학적 기술의 통합공정은 현장특이성(Site-specific) 확인후 적용가능성이 있음을 확인하였다.

  • PDF