• Title/Summary/Keyword: 동시촬영

Search Result 393, Processing Time 0.035 seconds

Kinetic Typography in Korean Film, 2012 (Study on the movie opening title sequence expression studies using kinetic typography) (키네틱 타이포그래피를 활용한 영화 오프닝타이틀 시퀀스 표현연구(2012 흥행작 중심으로))

  • Bang, Yoon-Kyeong
    • Cartoon and Animation Studies
    • /
    • s.31
    • /
    • pp.227-248
    • /
    • 2013
  • With the advancement of computers, opening title sequences in movies are continuously improving. Initially, titles and opening credits were created using what is called the optical method, whereby text was photographed on separate film and then copied onto the movies film negative. In contemporary movie making, however, the title sequence may be seamlessly integrated into the beginning of the movie by an insertion method that not only allows for more diverse technical expression, including the use of both 2D and 3D graphics, but also for its emergence as an independent art form. As such a title sequence, in as little as 50 seconds or up to 10 minutes, is able to convey the films concept while also suggesting more implicit intricacies of plot and thereby eliciting greater interest in the movie. Moreover, according to the directors intent and for a variety of purposes, the title sequence, while maintaining its autonomy, is inseparable from the movie as an organic whole; therefore, it is possible to create works that are highly original in nature. The purpose of this study is to analyze the kinetic typography that appears in title sequences of ten films produced by the Korean entertainment industry in 2012. Production techniques are analyzed in a variety of ways in order to predict the future direction of opening title sequences, as well as present aesthetic and technical models for their creation.

Acute Occlusal Change Following Acute Anterior Disc Displacement without Reduction: A Case Report (급성 비정복성 관절원판 변위에 따른 급성 교합변화의 증례)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.205-211
    • /
    • 2012
  • A 35 year-old female presented with the complaint of sudden occurrence of bite change and concurrent opening limitation, as well as pain in the right temporomandibular joint (TMJ) during mouth opening. From her history it was revealed that she had simple clicking of right TMJ for several years before onset of these symptoms, and that the clicking sound subsided recently after development of opening limitation. On clinical examination, anterior open bite, midline shift of the mandible to right, and premature contacts on left posterior teeth were observed. Maximum mouth opening and lateral movement to left were also restricted. On magnetic resonance images, the right TMJ showed anterior disc displacement without reduction and the posterior joint space is greatly collapsed by retrusion of the condyle. It was thought that the sudden occurrence of occlusal change would be resulted from abrupt displacement of the mandible associated with development of the anterior disc displacement without reduction. The stabilization appliance traction therapy was performed initially for first 3 months along with physical and pharmacologic therapy. However, the anterior open bite and opening limitation didn't resolve and the position of mandible still remained altered. So the stabilization appliance was changed to intermaxillary traction device. Then the mandible returned progressively to normal position and the occlusion became more stable and comfortable. After 5 months of intermaxillary traction therapy, the anterior open bite was dissolved completely and the occlusion became stabilized satisfactorily along with recovery of normal mouth opening range. On post-treatment magnetic resonance image, remodeling of condylar head was observed.

Composition of Foreground and Background Images using Optical Flow and Weighted Border Blending (옵티컬 플로우와 가중치 경계 블렌딩을 이용한 전경 및 배경 이미지의 합성)

  • Gebreyohannes, Dawit;Choi, Jung-Ju
    • Journal of the Korea Computer Graphics Society
    • /
    • v.20 no.3
    • /
    • pp.1-8
    • /
    • 2014
  • We propose a method to compose a foreground object into a background image, where the foreground object is a part (or a region) of an image taken by a front-facing camera and the background image is a whole image taken by a back-facing camera in a smart phone at the same time. Recent high-end cell-phones have two cameras and provide users with preview video before taking photos. We extract the foreground object that is moving along with the front-facing camera using the optical flow during the preview. We compose the extracted foreground object into a background image using a simple image composition technique. For better-looking result in the composed image, we apply a border smoothing technique using a weighted-border mask to blend transparency from background to foreground. Since constructing and grouping pixel-level dense optical flow are quite slow even in high-end cell-phones, we compute a mask to extract the foreground object in low-resolution image, which reduces the computational cost greatly. Experimental result shows the effectiveness of our extraction and composition techniques, with much less computational time in extracting the foreground object and better composition quality compared with Poisson image editing technique which is widely used in image composition. The proposed method can improve limitedly the color bleeding artifacts observed in Poisson image editing using weighted-border blending.

Integrated Color Matching in Stereoscopic Image by Combining Local and Global Color Compensation (지역과 전역적인 색보정을 결합한 스테레오 영상에서의 색 일치)

  • Shu, Ran;Ha, Ho-Gun;Kim, Dae-Chul;Ha, Yeong-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.168-175
    • /
    • 2013
  • Color consistency in stereoscopic contents is important for 3D display systems. Even with a stereo camera of the same model and with the same hardware settings, complex color discrepancies occur when acquiring high quality stereo images. In this paper, we propose an integrated color matching method that use cumulative histogram in global matching and estimated 3D-distance for the stage of local matching. The distance between the current pixel and the target local region is computed using depth information and the spatial distance in the 2D image plane. The 3D-distance is then used to determine the similarity between the current pixel and the target local region. The overall algorithm is described as follow; First, the cumulative histogram matching is introduced for reducing global color discrepancies. Then, the proposed local color matching is established for reducing local discrepancies. Finally, a weight-based combination of global and local matching is computed. Experimental results show the proposed algorithm has improved global and local error correction performance for stereoscopic contents with respect to other approaches.

A Case Report of Disseminated Extranodal Marginal Zone B-Cell Lymphoma of MALT Manifested by Solitary Pulmonary Nodule (고립성 폐결절로 발현한 파종성 림프절 외 변연부 B-세포 림프종 1예)

  • Cho, Joon Hyun;Jung, Jong Pil;Cha, Hee Jeong;Park, Chang Ryul;Kim, Sung Ryul;Kim, Hawk;Park, Jin Woo;Woo, Soon Joo;Eum, Eun A;Lee, Ki Young;Jegal, Yang Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.171-177
    • /
    • 2006
  • Extranodal marginal zone B-cell lymphoma of the mucosa-associated lymphoid tissue (MALT lymphoma) is usually indolent. Although it was reported recently that about 20-30% cases of MALT lymphoma presented with a disseminated disease at diagnosis, it was described as a disease localized at diagnosis and remaining stable for a prolonged period. However, only a few cases of MALT lymphoma involved the lung and gastrointestinal tract all at once. We report a case of a 73-year-old man with disseminated MALT lymphoma. He presented with non-productive cough, initial chest radiograph showed a nodule in the right lower lobe. The diagnosis of stage IV MALT lymphoma was made by CT scan, video-assisted thoracoscopic excisional biopy, gastrofiberscopic biopsy and bone marrow biopsy. The lymphoma involved the lung, stomach and bone marrow at the time of diagnosis. Because he refused chemotherapy, he discharged after Helicobacter pylori eradication without chemotherapy. Regular follow-up examination did not show any evidence of disease progression over 22 months.

SURGICAL EXTRACTION OF MULTIPLE SUPERNUMERARY TEETH BY TWO-STAGE PROCEDURE (상악 절치부에 매복된 다수 과잉치의 외과적 발거)

  • Hong, Eun-Hye;Kim, Seong-Oh;Lee, Jae-Ho;Choi, Hyung-Jun;Son, Heung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.333-338
    • /
    • 2008
  • Supernumerary teeth are characterized by an excess number of teeth, which can be responsible for a variety of irregularities in the primary and transitional dentition. Supernumerary teeth, especially in the maxillary anterior region, may prevent the eruption of adjacent permanent teeth and cause their ectopic eruption, diastema, root resorption, or formation of dentigerous cyst. Therefore, early diagnosis of supernumerary teeth is important for prevention of such complications, and adequate treatment should be given according to their location, number, and morphologic features. In this case, four supernumerary teeth in the maxillary anterior region were disturbing the eruption of adjacent permanent incisors. Two of them were located in proximity to the central incisor tooth germs that their immediate removal may injure the permanent tooth germs. In order to minimize such complications, surgical extraction of the four supernumerary teeth was performed in two stages. At first, only two inverted conical supernumerary teeth were extracted. The other two tuberculous supernumerary teeth, close to the permanent tooth germs, were extracted later after their natural dislocation. In that way, we could minimize affects on the neighboring permanent tooth germs and also the amount of alveolar bone removed during surgery.

  • PDF

Protocol Design for Fire Receiver­based Fire Detection Robots (화재수신기 기반의 화재감시로봇을 위한 프로토콜 설계)

  • Lim, Jong-Cheon;Lee, Jae-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.452-459
    • /
    • 2018
  • Conventional fire fighting robots are controlled by a remote control to monitor the fire scene or to suppress the fire. However, this method has a problem that it takes a long time to prepare robot and input it to fire place in the golden time after the fire, so that it can not sufficiently serve as a fire fighting robot. Using the autonomous driving fire monitoring robot, when a fire signal is generated, in conjunction with a fire receiver a moving robot takes a video of the fire scene and delivers the image to the fire department, so that the fire fighter can decide if it is real fire or not. Thereby it is possible to prevent a sudden spread of an accident by providing a quick judgment opportunity and at the same time suppressing the fire early. In this paper, we propose an architecture of the autonomous mobile fire monitoring robot and the communication protocol required for the robot to work with the fire receiver. A communication protocol is designed to control multiple fire monitoring robots in real time, and a communication with a fire receiver is designed as a hierarchical network to serve as an interface of an Ethernet network using wireless Wi-Fi. The fire monitoring robot and the wireless communication of the fire receiving period are implemented and the effectiveness of the operation is confirmed through the field test.

Prediction of Obstructive Coronary Artery Disease by Coronary Artery Calcification Finding on Low-dose CT Image for screening of lung diseases: Compared with Calcium Scoring CT (폐질환 선별검사를 위한 저선량 CT영상의 관상동맥 석회화 소견으로부터 폐쇄성 관상동맥질환 예측: 석회화수치 CT검사와 비교)

  • Lee, Won-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.333-341
    • /
    • 2011
  • To compare between calcium scoring CT (CSCT) and Low-dose CT (LDCT) image finding for coronary artery calcification (CAC) in screening of lung disease by MDCT. A total of 61 subjects who retired-workers exposed to inorganic dust were performed LDCT and CSCT by using a MDCT scanner on the same day, after be approved by the institutional review board, and obtaining the written informed consent from all subjects. LDCT images were read for detecting lung diseases as well as CAC by a experienced chest radiologist, then the subjects were divided either the positive group with CAC or the negative group without it. The CSCT was used to quantify and detect the presence of calcification in the coronary artery, and score of CAC calculated by using a Rapidia software (ver 2.8). In all coronary arteries, calcium score of positive group was higher better than that in negative group, especially in the total calcium (13.7 vs. 582.9, p=0.008) and the left anterior descending artery (3.2 vs. 249.0, p=0.006). CAC findings between CSCT and LDCT image were showed excellent agreement in cut-off point 100(K-value=0.80, 95% CI=0.69-0.91) from total calcium score. CAC findings on LDCT images showed the higher relation with CSCT. Therefore, the obstructive coronary artery disease could be predicted by CAC on LDCT images for screening of lung diseases.

A study of upper airway dimensional change according to maxillary superior movement after orthognathic surgery (양악 수술 시 상악골 상방 이동에 따른 상기도 변화)

  • Kim, Yong-Il;Park, Soo-Byung;Kim, Jong-Ryoul
    • The korean journal of orthodontics
    • /
    • v.38 no.2
    • /
    • pp.121-132
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the upper airway dimensional change according to maxillary superior movement after orthognathic surgery and to identify the relationship between the amount of maxillary movement and upper airway dimensional changes. Methods: The samples consisted of 24 adult patients (9 males and 15 females) who had a skeletal discrepancy and had received presurgical orthodontic treatment. They underwent Le Fort I superior impaction osteotomy and mandibular setback surgery. Cephalometric x-rays were taken at 3 stages - T0 (before orthognathic surgery), T1 (just or within 2 weeks after orthognathic surgery), T2 (6 months after surgery) Results: 1, Pharyngeal airway space (PAS (R)-nasopharynx) was decreased after surgery (T1) but recovered at 6 months after surgery; 2, Pharyngeal airway space (PAS (NL)-palatal plane) was increased after surgery and at 6 months after surgery; 3, Pharyngeal airway space (PAS (OL)-occlusal plane) was increased at T1 and was decreased at T2; 4, Soft palate thickness was increased at T1 but it became the same or thinner at T2; 5, There is no statistically significant relation between the amount of maxillary superior movement and pharyngeal airway space. Conclusions: These findings suggested that the maxillary superior movement of about an average of $4.40{\pm}1.14 mm$ did not affect upper pharyngeal airway space changes.

Accuracy Assessment of Feature Collection Method with Unmanned Aerial Vehicle Images Using Stereo Plotting Program StereoCAD (수치도화 프로그램 StereoCAD를 이용한 무인 항공영상의 묘사 정확도 평가)

  • Lee, Jae One;Kim, Doo Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.257-264
    • /
    • 2020
  • Vectorization is currently the main method in feature collection (extraction) during digital mapping using UAV-Photogrammetry. However, this method is time consuming and prone to gross elevation errors when extracted from a DSM (Digital Surface Model), because three-dimensional feature coordinates are vectorized separately: plane information from an orthophoto and height from a DSM. Consequently, the demand for stereo plotting method capable of acquiring three- dimensional spatial information simultaneously is increasing. However, this method requires an expensive equipment, a Digital Photogrammetry Workstation (DPW), and the technology itself is still incomplete. In this paper, we evaluated the accuracy of low-cost stereo plotting system, Menci's StereoCAD, by analyzing its three-dimensional spatial information acquisition. Images were taken with a FC 6310 camera mounted on a Phantom4 pro at a 90 m altitude with a Ground Sample Distance (GSD) of 3 cm. The accuracy analysis was performed by comparing differences in coordinates between the results from the ground survey and the stereo plotting at check points, and also at the corner points by layers. The results showed that the Root Mean Square Error (RMSE) at check points was 0.048 m for horizontal and 0.078 m for vertical coordinates, respectively, and for different layers, it ranged from 0.104 m to 0.127 m for horizontal and 0.086 m to 0.092 m for vertical coordinates, respectively. In conclusion, the results showed 1: 1,000 digital topographic map can be generated using a stereo plotting system with UAV images.