• Title/Summary/Keyword: 동시촬영

Search Result 393, Processing Time 0.027 seconds

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Analysis of Anatomical Conformity of Straight Antegrade Humeral Intramedullary Nail in Korean (한국인에서의 직선형 전향적 상완골 골수 내 금속정의 해부학적 적합성 분석)

  • Choi, Sung;Jee, Seungmin;Hwang, Seongmun;Shin, Dongju
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.498-503
    • /
    • 2021
  • Purpose: The aim of this study were to find ideal entry point of straight antegrade humeral intramedullary nail (SAHN) for the treatment of proximal humerus fracture in Korean and to analyze anatomical conformity using computed tomography. Materials and Methods: From May 2014 to October 2016, the study was conducted retrospectively on 74 Korean patients who had taken computed tomography on both normal and affected shoulder joint as result of shoulder injury. The mean age of the patients was 64.5 years (range, 22-95 years). Radiologic evaluation was done using multiplanar reconstruction technique of the computer tomography on normal proximal humerus. We located ideal entry point of SAHN as the point where humerus intramedullary center axis and humeral head meet. Distance between the entry point and local anatomical landmark was measured. We defined the critical distance as the distance between entry point and the most medial point of the supraspinatus attachment site. For adequate fixation and avoidance of injury to rotator cuff, critical distance should be over 8 mm according to Euler, and we defined the critical type when it is less than 8 mm. Critical distance, sex, age, height, body weight, body mass index was evaluated for the statistical significance. Results: The ideal entry point was as follows: the mean anteroposterior distance, the sagittal distance to the lateral margin of bicipital groove, was 11.5 mm and the mean mediolateral distance, the coronal distance to the lateral margin of grater tuberosity, was 20.5 mm. The mean critical distance, distance from the entry point to the just medial to insertion of the supraspinatus tendon, was 8.0 mm. Critical type with critical distance less than 8 mm was found in 41 in 74 patients (55.4%). Conclusion: The ideal entry point of SAHN in Korean was located on 11.5 mm posteriorly from the lateral margin of bicipital groove and 20.5 mm medially from lateral margin of greater tuberosity. More than half of the cases were critical type. Since critical type can possibly cause rotate cuff injury during nail insertion on entry point, surgeon should consider anatomical variance before choosing surgical option.

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

Cross-cultural Observation of Street Fashion of 2006 F/W in London/paris, New York, and Seoul (2006 F/W 런던/파리, 뉴욕, 서울 크로스 컬쳐럴 스트릿 패션 고찰)

  • Kim, Chil-Soon;Cassill, Nancy
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.12
    • /
    • pp.1939-1949
    • /
    • 2008
  • The purpose of this study was to identify differences or similarities across the ensembles of 2006 F/W fashion trends in the big fashion centers such as Paris, London, New York, and Seoul, by street fashion research. The study focuses on understanding of localized fashion trend in the marketplace. We used photograph observation and analyzed data by SPSS program. We found there is a significant difference in winter outfits at these different global fashion mega cities. Most Korean women were wearing light colored outer jackets and blue jeans were dominant style for pants. The majority of Paris/London, New York and Seoul people on the street were wearing wool/wool like coat. Padded coats were worn more by New Yorkers than by people in Seoul. For the bottom, there is a similarity between Paris/London, and New York City, in that skinny pants were popular. Koreans were wearing skinny pants mostly, but the percentage of mini skirts/shorts was also higher than any other cities. We found that the cross-cultural fashion mega trend is similar in clusters, but there is a slight difference of trend in clothing color, style and design details, and accessories by localized fashion cities. Not only direct observation but also identification of cultural characteristics and consumer behavior through the years will bring much more contributions to apparel industries.

The effect of growth hormone treatment on craniofacial growth in short stature children (저신장 소아에서 성장호르몬 치료가 두개안면골 성장에 미치는 영향)

  • Chung, Sung-Ho;Kim, Jin-Wook;Park, Yong-Hoon;Hwang, Chung-Ju;Lee, Hee-Kyung
    • The korean journal of orthodontics
    • /
    • v.40 no.4
    • /
    • pp.227-238
    • /
    • 2010
  • Objective: The purpose of this study was to analyze the effect of growth hormone treatment (GHT) on craniofacial growth in children of short stature. Methods: Nineteen untreated children of short stature were referred from the Pediatric Department, Yeungnam University Hospital as a subject group. All subjects had lateral cephalograms taken before, after 1 year and after 2 years of growth hormone treatment. As a reference group, we selected 19 normal children with paired sampling who matched the subjects' age and sex, from the Department of Orthodontics, Kyungpook National University Hospital. Results: Before GHT, anterior cranial base length and upper posterior facial height, posterior total facial height, mandibular ramus length, and mandibular corpus length were significantly smaller in the reference group. In angular craniofacial measurements, saddle angle and mandibular plane angle were larger. SNA and SNB were smaller in the reference group. After two years of GHT, growth hormone accelerated growth in several craniofacial components. The posterior total facial height, the anterior, posterior cranial base length, and the mandibular ramus length were increased. And the difference in mandibular plane angle and ANB values compared with the reference group was decreased. Conclusions: GHT over 2 years leads to a craniofacial catch-up growth tendency, which is pronounced in interstitial cartilage and condylar cartilage.

Reversible Watermarking based on Predicted Error Histogram for Medical Imagery (의료 영상을 위한 추정오차 히스토그램 기반 가역 워터마킹 알고리즘)

  • Oh, Gi-Tae;Jang, Han-Byul;Do, Um-Ji;Lee, Hae-Yeoun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.5
    • /
    • pp.231-240
    • /
    • 2015
  • Medical imagery require to protect the privacy with preserving the quality of the original contents. Therefore, reversible watermarking is a solution for this purpose. Previous researches have focused on general imagery and achieved high capacity and high quality. However, they raise a distortion over entire image and hence are not applicable to medical imagery which require to preserve the quality of the objects. In this paper, we propose a novel reversible watermarking for medical imagery, which preserve the quality of the objects and achieves high capacity. First, object and background region is segmented and then predicted error histogram-based reversible watermarking is applied for each region. For the efficient watermark embedding with small distortion in the object region, the embedding level at object region is set as low while the embedding level at background region is set as high. In experiments, the proposed algorithm is compared with the previous predicted error histogram-based algorithm in aspects of embedding capacity and perceptual quality. Results support that the proposed algorithm performs well over the previous algorithm.

A Test of a Far Infrared Camera for Development of New Surface Image Velocimeter for Day and Night Measurement (주야간 겸용 표면영상유속계 개발을 위한 원적외선 카메라의 적용성 검토)

  • Yu, Kwonkyu;Kim, Seojun;Yoo, Byeongnam;Bae, Inhyuk
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.659-672
    • /
    • 2015
  • In flow velocity measurement of natural rivers, taking images with proper image quality is the fundamental and the most important step. Since flood peaks generally occur in night time, it is very difficult to capture proper images in that time. The present study aims to test a far infra-red camera as a adequate alternative to resolve the various problems in measuring flood discharges. The far infra-red cameras are able to capture images in night time without help of any extra illuminations. Futhermore they are not affected by fog nor smoke, hence they can be adapted for a fixed-type surface image velocimeters. For comparison, a commercial camcorder and a near infra-red cameras were used together. The test images were taken at a day time and a night time, and the image acquisition work were performed at an artificial flow channel of the Andong River Experiment Station. The analyzed results showed that the far infra-red camera would be a good instrument for surface image velocimeters, since they were able to capture regardless light condition. There are, however, a few minor problems in their accuracy of the analyzed results. About their accuracy a more study would be required.

Effective Volume Rendering and Virtual Staining Framework for Visualizing 3D Cell Image Data (3차원 세포 영상 데이터의 효과적인 볼륨 렌더링 및 가상 염색 프레임워크)

  • Kim, Taeho;Park, Jinah
    • Journal of the Korea Computer Graphics Society
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, we introduce a visualization framework for cell image data obtained from optical diffraction tomography (ODT), including a method for representing cell morphology in 3D virtual environment and a color mapping protocol. Unlike commonly known volume data sets, such as CT images of human organ or industrial machinery, that have solid structural information, the cell image data have rather vague information with much morphological variations on the boundaries. Therefore, it is difficult to come up with consistent representation of cell structure for visualization results. To obtain desired visual representation of cellular structures, we propose an interactive visualization technique for the ODT data. In visualization of 3D shape of the cell, we adopt a volume rendering technique which is generally applied to volume data visualization and improve the quality of volume rendering result by using empty space jittering method. Furthermore, we provide a layer-based independent rendering method for multiple transfer functions to represent two or more cellular structures in unified render window. In the experiment, we examined effectiveness of proposed method by visualizing various type of the cell obtained from the microscope which can capture ODT image and fluorescence image together.