• Title/Summary/Keyword: 동관

Search Result 67, Processing Time 0.027 seconds

Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes (세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성)

  • Son, Chang-Hyo
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.151-158
    • /
    • 2007
  • An experimental study to investigate the condensing heat transfer characteristics of small diameter horizontal double pipe heat exchangers with R-22 and R-410A was performed. Experimental facility was constructed to calculate and observe HTC(heat transfer coefficients), flow patterns and pressure drop. The main components include a liquid pump, an evaporator, a condenser(test section), a sight-glass, pressure taps and measurement apparatus. Two pipes of different diameters are tested; One 5.35 mm ID 0.5 mm thick, the other 3.36 mm ID 0.7 mm thick. The mass flow rate ranged from 200 to $500\;ks/m^2{\cdot}s$ and heating capacity were form 1.0 to 2.4 kW. The flow patterns of R-22 and R-410A were observed with a high speed camera through the sight-glass. The tests revealed that HTC of R-410A was higher than that of R-22 by maximum 5%. Annular pattern was observed for the most cases but stratified flow was also detected when x<0.2. The pressure drop in 3.36 mm ID pipe was higher than that of 5.35 mm by $30{\sim}50%$. Comparing with previous correlations such as Shah, Fujii and Soliman's, Fujii' showed the best good agreement with my data with a maximum deviation of 40%.

  • PDF

A study on the explosion proof by the electric discharge on voltage application type (전압인가식 제전기의 방폭화에 관한 연구)

  • Lee Chun Ha;Kim Jum Ho;Park Min Young
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.4 s.25
    • /
    • pp.62-69
    • /
    • 2004
  • It is necessary to eliminate the electric static for the prevention of disasters by electric static discharge, the improvement of production efficiency, the protection of a sensitive electronic devices in the variable manufacturing processes. Then it is handled for elimination of electric static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the ideal condition of electric static elimination efficiency by changing of the length of voltage input type eliminator's bar, the length of copper pipe and the gap of electrode and the existence of explosion by inflammable gas with that conditions. As the result, the electric static elimination efficiency has the most ideal value at the 8-11(mm) gap of the earth electrode and needle type electrode each elimination bar and there is not explode at the explosive experiment of inflammable gas with the ideal elimination bar. We can consider that there are some data which are needed for elimination efficiency and it will be able to protect the occurrence of explosion accident inflammable nas in the industrial fields.

  • PDF

A Study on The Construction of Choryang-Waegwan (초량왜관의 조영활동에 관한 연구)

  • Chung Ye-Jung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.195-216
    • /
    • 2005
  • This study concerns especially Choryang-Weagwan which was the largest Japanese House left in Pusan through Chosun Dynasty.Choryang-Waegwan was known to have been jointly constructed by Korean and Japanese carpenters. Therefore, Weagwan was a place for exchange of architectural tradition (special features such as sliding door and straw mat) between Korean and Japan. Judging from this point of view, It is certain that mutual influences helped to shape architecture of Choryang-Weagwan. After establishment Choryang-Weagwan was gradually extended, owing to the prosperity of trade with Japan. But since late 18th century government of Chosun did not give as much care to maintaining Choryang-Weagwan as a result of deteriorating condition of commercial and diplomatic relations with Japan. From the beginning of Choryang-Weagwan construction, Superintendents of the construction were called Hun-do and Byl-cha, who acted as official interpreters as well. And, during construction works, they were called Gamdong-gwan. At the start of construction, Weagwan was built partly in Japanese-style by the carpenters from Tokugawa Shogunate. But as time passed, the participation rate of Japanese carpenters diminished gradually. After 1831, Japanese technician vanished extremely and repairing construction was continued by the Korean

  • PDF

Structural Stability Analysis of One-Touch Insertion Type Pipe Joint for Refrigerant (냉매용 원터치 삽입식 파이프 조인트의 안전성 구조해석)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.542-549
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the structural stability of the 6.35 and 15.88 socket models, which are integrated insert type connectors developed by a company, using FEM. For structural analysis, HyperMesh as pre-processor, HYPER VIEW as post-processor, and LS-DYNA as solver were used. Result: In the case of 6.35 socket, the maximum stresses at hook, holder and hinge were 95.02MPa, 19.59MPa and 44.01MPa, respectively, and in case of 15.88 socket, it was 127.7 MPa, 40.09MPa and 45.23MPa, respectively. Conclusion: Comparing the stress distribution of the two socket models, the stress in the 15.88 socket, which has a relatively large outer diameter, appears to be large overall, but it is significantly lower than the yield stress of each material, indicating that there is no problem in structural safety in both models.

Flow Safety Assessment by CFD Analysis in One-Touch Insertion Type Pipe Joint for Refrigerant (CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 유동 안전성 평가)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.550-559
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the safety by flow analysis of the 6.35 inch socket model, which are integrated insert type connectors developed by a company, using CFD analysis technique. For CDF analysis, RAN model and LES model are used. Result: As results of the analysis, amplitude of the pressure fluctuation acting on the wall of the piping system is formed at a level of 3,780 Pa or less, which is a very small level of pressure compared with the operating pressure or design stress of the refrigerant piping. Conclusion: These results mean that the effect of vibration caused by turbulence on the structural safety of the pipe is negligible.

Relation of Neoaortic Root Dilation and Aortic Insufficiency after Arterial Switch Operation (동맥전환술 후의 신생대동맥근부 확장과 대동맥판막폐쇄부전의 관계)

  • 박한기;김도균;홍유선;이종균;최재영;조범구;박영환
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.921-927
    • /
    • 2003
  • Arterial switch operation (ASO) has been the most effective surgical option for transposition of the great arteries. But, the inappropriate dilation of the neoaortic root has been reported and its effect on neoaortic valve function and growth of aorta has not been well documented. Material and Method: Forty-eight patients who underwent cardiac catheterization during follow up after arterial switch operation were included in this study. Arterial switch operation was performed at a median age of 18 days (range 1∼211 days). Preoperative cardiac catheterization was performed in 26 patients and postoperative catheterization was performed in all patients at 15.8$\pm$9.6 months after ASO. Postoperative ratios of the diameters of neoaortic annulus, root and aortic anastomosis against the descending aorta were compared to the size of preoperative pulmonary annular, root and sinotubular junction. Preoperative and operative parameters were analyzed for the risk factors of neoaortic insufficiency. Result: There were two clinically significant neoaortic insufficiencies (grade$\geq$II/IV) during follow up, one of which required aortic valve replacement. Another patient required reoperation due to aortic stenosis on the anastomosis site. Post-operatively, neoaortic annulus/DA ratio increased from 1.33$\pm$0.28 to 1.52$\pm$.033 (p=0.01) and neoaortic root/DA ratio increased form 2.02$\pm$0.40 to 2.56$\pm$0.38 (p<0.0001). However, the aortic anastomosis/DA ratio showed no statistically significant difference (p=0.06). There was no statistically significant correlation between the occurrence of neoaortic insufficiency and neoaortic annulus/DA ratio and neoaortic root/DA ratio. Non-neonatal repair (age>30days) (p=0.02), preopeative native pulmonaic valve stenosis (p=0.01), and bisuspid pulmonic valve (p=0.03) were the risk factors for neoaortic insufficiency in univariate risk factor analysis. Conclusion: After ASO, aortic anastomosis site showed normal growth pattern proportional to the descending aorta, but neoaortic valve annulus and root were disproportionally dilated. Significant neoaortic valve insufficiency rarely developed after ASO and neoaortic annulus and root size do not correlate with the presence of postoperative neoarotic insufficiency. ASO after neonatal period, preoperative native pulmonary valve stenosis, and bicuspid native pulmonic valve are risk factors for the development of neoaortic insufficiency.

Location and Construction Characteristics of Imdaejeong Wonlim based on Documentation (기문(記文)을 중심으로 고찰한 임대정원림(臨對亭園林)의 입지 및 조영 특성)

  • Rho, Jae-Hyun;Park, Tae-Hee;Shin, Sang-Sup;Kim, Hyoun-Wuk
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.4
    • /
    • pp.14-26
    • /
    • 2011
  • Imdaejeong Wonlim is located on the verge of Sangsa Village in Sapyeong-ri, Daepyeong-myeon, Hwasun-gun Gyeongsangnam-do toward Northwest. It was planned by Sa-ae, Minjuhyeon in 1862 on the basis of Gobanwon built by Nam Eongi in 16th century against the backdrop of Mt. Bongjeong and facing Sapyeong Stream. As water flows from west to east in the shape of crane, this area is a propitious site standing for prosperity and happiness. This area shows a distinct feature of Wonlim surrounding the Imdaejeong with multi layers as consisting of 5 districts - front yard where landmark stone with engraved letters of 'Janggujiso of Master Sa-ea' and junipers are harmoniously arranged, internal garden of upper pavilion ranging from a pavilion to square pond with a little island in the middle, Sugyeongwon of under pavilionu consisting of 2 ponds with a painting of three taoist hermits, forest of Mt. Bonggeong and external garden including Sapyeong Stream and farmland. According to documentation and the results of on-site investigation, it is certainly proved that Imdaejeong Wonlim was motivated by Byeoseo Wonlim which realized the idea of 'going back to hometown after resignation' following the motives of Janggujiso, a hideout aimed to accomplish the ideology, 'training mind and fostering innate nature,' on the peaceful site surrounded by water and mountain, as well as motives of Sesimcheo(洗心處) to be unified with morality of Mother Nature, etc. In addition, it implies various imaginary landscapes such as Pihangji, Eupcheongdang, square pond with an island and painting of three Taoist hermits based on a notion that 'the further scent flies away, the fresher it becomes,' which is originated from Aelyeonseol(愛蓮說). In terms of technique of natural landscape treatment, divers techniques are found in Imdaejeong Wonlim such as distant view of Mt. Bongjeong, pulling view with an intention of transparent beauty of moonlight, circle view of natural and cultural sceneries on every side, borrowed scenary of pastoral rural life adopted as an opposite view, looked view of Sulyundaero, over looked view of pond, static view in pavilion and paths, close view of water space such as stream and pond, mushroom-and-umbrella like view of Imdaejeong, vista of pond surrounded by willows, imaginary view of engraved letters meaning 'widen knowledge by studying objectives' and selected view to comprise sunrise and sunset at the same time. In the beginning of construction, various plants seemed to be planted, albeit different from now, such as Ginkgo biloba, Phyllostachys spp., Salix spp., Pinus densiflora, Abies holophylla, Morus bombycis, Juglans mandschurica, Paulownia coreana, Prunus mume, Nelumbo nucifera, etc. Generally, it reflected dignity of Confucianism or beared aspect of semantic landscape implying Taoist taste and idea of Phoenix wishing a prosperity in the future. Furthermore, a diversity of planting methods were pursued for such as liner planting for the periphery of pond, bosquet planting and circle planting adopted around the pavilion, spot planting using green trees, solitary planting of monumentally planted Paulownia coreana and opposite planting presenting the Abies holophylla into yin and yang.