• Title/Summary/Keyword: 동공

Search Result 398, Processing Time 0.029 seconds

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

Macrocyclic Complexes of Actinide and Lanthanide Metals (Ⅰ). Formation and Properties of Cation Complexes with Macrocyclic Ligands (악틴 및 란탄족금속의 거대고리 착물 (제 1 보). 거대고리 리간드의 금속착물의 형성과 성질)

  • Jeong, O Jin;Choe, Chil Nam;Yun, Seok Jin;Son, Yeon Su
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.143-158
    • /
    • 1990
  • Metal complexes were prepared by reacting uranium (Ⅵ), thorium (Ⅳ) and rare earth metal (Ⅲ) ions including Nd (Ⅲ), Sm (Ⅲ) and Ho (Ⅲ) with macrocyclic ligands including five crown ethers, nine crownands and one cryptand ligands, and subjected to NMR studies in order to examine coordination sites of the ligands and compositions of the complexes formed. Among the marcocyclic ligands, crown ethers and crownand ligands have shown down-field shifts of the methylene protons of the lcigands by forming stable complexes with all the metal ions and the differences of chemical shifts were decreased as increasing of the cavity-size of crown ethers for the same metal ions and decreasing of the atomic number of the rare earth metals for the same ligands. It has been found that crownand 22 gave a stable complex with uranium(Ⅵ) ion by the coordination through both oxygen and nitrogen atoms of the ligand whereas no complex was formed with the rare earth metal(Ⅲ) ions, which on the other hand were found to form stable complexes with cryptand 221. The rest of the crowand ligands have also been found to form stable complexes with uranium(Ⅵ) ion by coordinating through all the oxygen and nitrogen atoms of the ligands whereas no complexes were formed with the rare earth metal(Ⅲ) ions. It has also been shown by 1H-NMR study that uranium(Ⅵ), thorium(Ⅳ) and rare earth metal(Ⅲ) ions formed 1:1 complexes with the macrocyclic ligands except for thorium(Ⅳ) complex of 12C4 in which the mole ratio of metal to ligand is 1:2. More stable metal complexes show larger changes in chemical shifts of the coordinated ligand protons. Finally, the rare earth metal(Ⅲ) complexes of 18C6 have shown ligand exchange reaction with the solvent molecules in acetylacetone solution, which was not observed for the uranium (Ⅵ) complexes.

  • PDF

Assessment of Dynamic Stereoacuity of Adults in their 20s' with Howard-Dolman Test (하워드-돌먼 입체검사를 이용한 20대 성인의 동적 입체시 평가)

  • Shim, Hyun-Suk;Choi, Sun-Mi;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.61-66
    • /
    • 2015
  • Purpose: In this study, dynamic stereoacuity of 20s' adults were measured by using the Howard-Dolman test(H-D TEST, Bernell, U.S.A), and compared of male and female. And the correlation between dynamic stereoacuity and PD(pupillary distance), and between dynamic stereoacuity and anisometropia caused by difference in the spherical refractive power of the left and right eyes were analyzed. Methods: The mean age of $22.68{\pm}0.50$(20~29)years old, 20s' 63 adults (30 male, 33 female) were conducted for this experiments. After the full correction of subject's refractive error, dynamic stereoacuity was measured 5 times for 1 subject at 2.5 m distance using the H-D test. at 2.5 distance. Results: The mean of dynamic stereoacuity was $28.44{\pm}25.03$ sec of arc for total subjects, $28.23{\pm}23.34$ sec of arc for male, and $28.63{\pm}26.83$ sec of arc for female. In the dynamic stereoacuity classified by the range of inter-pupil distance (IPD), the dynamic stereoacuity was $33.87{\pm}18.53$ sec for the IPD being under 59.80 mm, $26.24{\pm}25.26$ sec of arc for 59.81~66.15 mm, $34.60{\pm}25.65$ sec of arc for over 66.15 mm. However, there were no significant differences between 3 groups (P=0.73, r=0.03). In dynamic stereoacuity classified by the refractive error difference between two eyes, dynamic stereoacuity was $26.81{\pm}24.86$ sec of arc for the under 1 D, $41.45{\pm}24.18$ sec of arc for over 1 D, and there was no significant difference between two groups (P=0.15, r=0.15). Conclusions: Dynamic stereacuity by the H-D test in 20s adults showed that there was no significant differences between male and female, and PD and anisometropia did not have a significant impact upon the dynamic stereoacuity.

Comparison between Response AC/A and CA/C Ratio according to Additional Spherical Powers and Prism Powers (가입렌즈 도수와 프리즘 굴절력 변화에 따른 반응 AC/A비와 CA/C비 비교)

  • Roh, Byeong-Ho;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.341-347
    • /
    • 2015
  • Purpose : This study was to examine a correlation of response AC/A ratio by additional spherical powers with PD(Pupilary distance) and relative accommodation, and was to investigate correlation of CA/C ratio by prism powers. The mean differences between a reciprocal response AC/A ratio and a CA/C ratio were compared, and were suggested to be used as data in the refractive power and prism prescriptions in the clinical. Methods: The open field autorefractometer (Nvision-K 5001, Shin nippon) and Howell target at 40 cm fixation distance to 62 persons with average $22.62{\pm}2.84$ ages were used to measure the response AC/A ratio according to additional Spherical powers. The CA/C ratios were measured using the DOG card at 40cm according to prism powers. Results: When the response accommodation according to Additional Spherical power changes and the response accommodation according to prism power changes were compared, it was larger than the response accommodation according prism power change. These were significant differences statistically. The correlation of response AC/A ratio and PD is showed as r = -0.158, the CA / C ratio is shown as r = 0.093. The correlation of response AC/A ratio and relative accommodation showed as r = -0.253, the CA/C ratio showed as r = 0.566 that is predictable correlation. The correlation of response AC/A ratio and CA/C ratio showed as r = -0.355 that is low minus correlation (p = 0.000). The difference between a reciprocal response AC/A ratio and a CA/C ratio showed $0.12{\pm}0.06D/{\Delta}$ with a significant difference statistically (p=0.000). Conclusions: The correlation of relative accommodation and CA/C ratio showed that depend on the individual, The more a relative accommodation is, the higher a response accommodation of convergence by convergence stimulus is. The reciprocal response AC/A and CA/C ratio showed significant differences statistically. This can have higher CA/C ratio in patients with low AC/A ratio in clinical as an independent variable. Thus when the abnormal binocular vision was prescribed in the clinical, it is necessary to consider the accommodative response even if the AC/A ratio is a normal range.

A Study on Wafer-Level 3D Integration Including Wafer Bonding using Low-k Polymeric Adhesive (저유전체 고분자 접착 물질을 이용한 웨이퍼 본딩을 포함하는 웨이퍼 레벨 3차원 집적회로 구현에 관한 연구)

  • Kwon, Yongchai;Seok, Jongwon;Lu, Jian-Qiang;Cale, Timothy;Gutmann, Ronald
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.466-472
    • /
    • 2007
  • A technology platform for wafer-level three-dimensional integration circuits (3D-ICs) is presented, and that uses wafer bonding with low-k polymeric adhesives and Cu damascene inter-wafer interconnects. In this work, one of such technical platforms is explained and characterized using a test vehicle of inter-wafer 3D via-chain structures. Electrical and mechanical characterizations of the structure are performed using continuously connected 3D via-chains. Evaluation results of the wafer bonding, which is a necessary process for stacking the wafers and uses low-k dielectrics as polymeric adhesive, are also presented through the wafer bonding between a glass wafer and a silicon wafer. After wafer bonding, three evaluations are conducted; (1) the fraction of bonded area is measured through the optical inspection, (2) the qualitative bond strength test to inspect the separation of the bonded wafers is taken by a razor blade, and (3) the quantitative bond strength is measured by a four point bending. To date, benzocyclobutene (BCB), $Flare^{TM}$, methylsilsesquioxane (MSSQ) and parylene-N were considered as bonding adhesives. Of the candidates, BCB and $Flare^{TM}$ were determined as adhesives after screening tests. By comparing BCB and $Flare^{TM}$, it was deduced that BCB is better as a baseline adhesive. It was because although wafer pairs bonded using $Flare^{TM}$ has a higher bond strength than those using BCB, wafer pairs bonded using BCB is still higher than that at the interface between Cu and porous low-k interlevel dielectrics (ILD), indicating almost 100% of bonded area routinely.

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

On the Histopathological Changes and Methemoglobinemia to Nitrite Toxicity in the Culture Farms of Eel, Anguilla japonica (참장어(뱀장어) Anguilla japonica 양어장(養魚場)에서의 아질산(亞窒酸) 중독(中毒)에 의한 Methemoglobin증(症)과 병리조직학적(病理組織學的) 변성(變性))

  • Yang, Han-Choon;Chun, Seh-Kyu
    • Journal of fish pathology
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 1991
  • Histopathological changes and methemoglobinemia of the eels (Anguilla japonica) reared at six culture farms in the vicinity of Y$\check{o}$su city were investigated under the conditions of $22.0{\sim}29^{\circ}C$, 4.33~7.33ppm of D.O., pH 6.1~8.2 and 0.03~10.1ppm of nitrite from December, 1989 to June, 1990. All of the eels showed no any abnormal state in action, color and blood, but the eels reared in pH 6.0 had planty of mucus and stickiness on their body surface. Methemoglobin levels were 1.03~9.86% of total erythrocyes in Dec. and 5.05~25.69% in June, and poikilocyte levels were 5.8~30.17% in Dec. and 8.67~74.45% in June. These results indicate the fact that the water management of the culture farms was worse in summer than in winter, even though not good in winter. Hypertrophy was found in the gill, hepatic and kidney tissue of the eels in all the culture farms. In March and June, Fish of all culture farms appeared the detachment of gill lamella epithelium cells, pyknosis and sinusoids of nucleus in the hepatic tissue and hemosiderosis in the kidney tissue. The trend of increase in methemoglobin levels appeared in the fish of culture farms with high nitrite concentration, which didn't appear equally in all the culture farms. However, in the culture farms of pH 6.0, methemoglobin and poikilocyte levels were increased independently of concentration of nitrite, and degeneration in the tissue of the gill, liver and kidney was also appeared.

  • PDF

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Robust Eye Localization using Multi-Scale Gabor Feature Vectors (다중 해상도 가버 특징 벡터를 이용한 강인한 눈 검출)

  • Kim, Sang-Hoon;Jung, Sou-Hwan;Cho, Seong-Won;Chung, Sun-Tae
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.1
    • /
    • pp.25-36
    • /
    • 2008
  • Eye localization means localization of the center of the pupils, and is necessary for face recognition and related applications. Most of eye localization methods reported so far still need to be improved about robustness as well as precision for successful applications. In this paper, we propose a robust eye localization method using multi-scale Gabor feature vectors without big computational burden. The eye localization method using Gabor feature vectors is already employed in fuck as EBGM, but the method employed in EBGM is known not to be robust with respect to initial values, illumination, and pose, and may need extensive search range for achieving the required performance, which may cause big computational burden. The proposed method utilizes multi-scale approach. The proposed method first tries to localize eyes in the lower resolution face image by utilizing Gabor Jet similarity between Gabor feature vector at an estimated initial eye coordinates and the Gabor feature vectors in the eye model of the corresponding scale. Then the method localizes eyes in the next scale resolution face image in the same way but with initial eye points estimated from the eye coordinates localized in the lower resolution images. After repeating this process in the same way recursively, the proposed method funally localizes eyes in the original resolution face image. Also, the proposed method provides an effective illumination normalization to make the proposed multi-scale approach more robust to illumination, and additionally applies the illumination normalization technique in the preprocessing stage of the multi-scale approach so that the proposed method enhances the eye detection success rate. Experiment results verify that the proposed eye localization method improves the precision rate without causing big computational overhead compared to other eye localization methods reported in the previous researches and is robust to the variation of post: and illumination.