• Title/Summary/Keyword: 동공

Search Result 398, Processing Time 0.033 seconds

A Comparison of the Movements of Circle Contact Lens and Soft Contact Lens with Identical Material on Cornea (써클 콘택트렌즈와 동일 재질 소프트 콘택트렌즈의 각막에서의 움직임 비교)

  • Kim, So Ra;Park, Sang Hee;Joo, Seon-Ok;Lee, Hye Rim;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2012
  • Purpose: The present study was conducted to compare any difference caused by pigmentation in the centrations and movement patterns on the cornea between circle and soft contact lens with identical material and parameters during lens wearing. Methods: Soft and circle contact lenses with identical material and parameters were applied to twenty eyes with normal tear volume for 3 hrs a day during a total of 5 days and then their lens centrations, the moving distances and rotations by repeat blinking were compared. Results: The lens centration beyond the fitting criteria was shown in initial wears of both soft contact lens and circle contact lens. However, the centration of soft contact lens was changed to the pupil center for being suitable to the fitting criteria with longer wearing time. On the other hand, the decentration of circle contact lens in the horizontal direction was still presented even with longer wearing time. The moving distances of soft contact lens and circle contact lens decreased with the expand of lens wearing but were not significantly different between total wearing period and daily wearing time. The rotation of circle contact lens by repeat blinking was significantly different from that of soft contact lens even when the wearing period was extended. Conclusions: We revealed that the lens centration and movement of circle contact lens on cornea were different from those of regular soft contact lens resulting in bigger difference with the expand of wearing period in the study.

The Performance Analysis and Design of Selling Spectacle Lenses in Domestic Market (국내 시판 안경렌즈의 성능 분석 및 설계)

  • Kim, Se-Jin;Lim, Hyeon-Seon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.355-360
    • /
    • 2010
  • Purpose: Analysis performance for spectacle lens which sales in domestic market and optimization design a spectacle lens which is corrected aberration. Methods: Measured center thickness, radius and aspherical surface coefficient for spherical and aspherical lenses which were ${\pm}$5.00D. Refractive index for every lens was 1.6 and they came from 4 different companies. I used 3 types of equipment to measure lenses. ID-F150 (Mitutoyo) : Center Thickness, FOCOVISION (SR-2, Automation Robotics) : Radius, PGI 1240S (Taylor Hobson) : Aspherical surface coefficient. Designed a lens which had 27 mm of distance from lens rear surface to center of eye, 4 mm of pupil diameter and small aberration on center vision $30^{\circ}C$. To shorten axial distance compared with the measured lens rise merits for cosmetic. Lens Design tool was CODE V (Optical Research Associates). Results: -5.00D aspherical lens had somewhat high astigmatism and distortion compared with the spherical lens. But it had a merit for cosmetic because of short axial height and decrease edge thickness. Improved a performance of distortion and ascertain merits for cosmetic due to short axial height and decrease edge thickness same as (-) lens in case of +5.00 aspherical lens. Though an optimization process front surface aspherical lens had a good performance for astigmatism and distortion and the merit for beauty compared with measured spherical lens. Conclusions: Design trend for domestic aspherical lens is decrease axial height and thickness to increase a merit for cosmetic not but increase performance of aberration. From design theory for optimization design front surface aspherical spectacle lens which has improved performance of aberration and merit for cosmetic at the same time compared with the measured lens. Expect an improved performance from design back aspherical lens compared with front aspherical lens.

The Road Subsidence Status and Safety Improvement Plans (도로함몰 실태와 안전관리 개선 방안)

  • Bae, Yoon-Shin;Kim, Kyoon-Tai;Lee, Sang-Yum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.545-552
    • /
    • 2017
  • Ground subsidence can result in the formation of sinkholes, potholes, settlement of structures, and road subsidence. Road subsidence is described as the sudden collapse of the road surface into subsurface cavities caused by the loss of bearing capacity in the ground, such as the dissolution of limestone by fluid flow in the surface causing the formation of voids leading to subsidence at the surface. Road subsidence occurs about 665 times annually, and this incidence has been increasing until 2013. Damaged underground facilities, management negligence, and lowering of the ground water table have been the causes of road subsidence in Seoul. Seoul metropolitan government announced special management counter plans to relieve the anxieties and make the roads safe for passing. Construction sites, such as excavation works, need to be managed properly because they have strong potential to induce road subsidence. The aim of this study was to identify the main causes of road subsidence and suggest management plans. First, life cycle cost analysis revealed the daytime construction to be more appropriate than nighttime. In addition, by analyzing the limitations of using sand as a backfill material, it is proposed to use a flowable backfill material instead of sand. Finally, to reduce the blind spots, which is a problem in surveying the road pavement conditions of local governments, the road to be managed is divided into several zones, and a specialized agency is selected for each zone and a method of surveying the blind spots through collaboration is suggested.

Preparation and properties of antibacterial activated carbon fiber (항균성 탄소섬유의 제조와 특성)

  • 오원춘;김범수;임창성;장원철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.4
    • /
    • pp.165-171
    • /
    • 2002
  • The study on the adsorption, the surface properties and the antibacterial effects of the metal-treated pitch based activated carbon fibers was carried out. From the adsorption studies on the series of metal-treated activated carbon fiber, the specific surface areas of the metal treated activated carbon fiber obtained from BET equation were in the range of 113.2~1574 $m^2$/g for the Ag-ACFs. And that of Cu treated ACF are distributed to 688.2-887.8 $\m^2$/g. And, the specific surface areas of the Ni-treated pitch based ACFs were in the range of 692.6~895.2 $\m^2$/g. From the ${\alpha}_s$- method, 0.06~1.1 cm^3/g of the micropore volumes were obtained from Ag-ACFs. And, 0.1~0.2 cm^3/ and 0.2~0.6 cm^3/g of the micropore volumes were obtained from Cu and Ni-ACFs, respectively. And, from the SEM morphology results, it was observed that the surface of activated carbon fiber are partially blocked and coated by metal after the treatment. Finally, from the antibacterial effects of metal-treated activated carbon fiber against E. coli, the areas of antibacterial effect become larger with the increase in mole ratio of metal treated. And, from the antibacterial effects using Shake flask method against E. coli, the percentage of the effects was 92.5~100 % and the antibacterial effect was increased with the increase in mole concentration of metal treated.

Synthesis of Ti-SBA-15 Doped with Lanthanide Ions and Their Photocatalytic Activity (란탄족 이온이 도핑된 Ti-SBA-15의 합성 및 그들의 광촉매 활성)

  • Hong, Seong-Soo
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • Ti-SBA-15 catalysts doped with lanthanide ions (Ln/Ti-SBA-15) were successfully synthesized using conventional hydrothermal method. In addition, they were characterized by XRD, FT-IR, DRS, BET, and PL. The activity of these materials on the photocatalytic decomposition of methylene blue under ultraviolet light irradiation was also examined. Ti-SBA-15 catalysts doped with various lanthanide ions maintained their mesoporous structure. The pore size and pore volume of Ln/Ti-SBA-15 materials decreased but their surface area increased upon the doping of lanthanide ion. Ln/Ti-SBA-15 materials exhibited the type IV nitrogen isotherm with desorption hysteresis loop type H2, which was characteristic of mesoporous materials. The size of hysteresis increased in the doping of lanthanide ions on Ti-SBA-15 material. There was no absorption in the visible region (> 400 nm) regardless of the doping of lanthanide ions to TiO2 particles, while the broad bands at 220 nm appeared at the Ln/Ti-SBA-15 samples, indicating the framework incorporation of titanium into SBA-15. 1 mol% Pr/ Ti-SBA-15 catalysts showed the highest photocatalytic activity on the decomposition of methylene blue but the Ti-SBA-15 catalysts doped with Eu, Er, and Nd ions showed lower activity compared to pure Ti-SBA-15 catalyst. The PL peaks appeared at about 410 nm at all catalysts while the excitonic PL signal was proportional to the photocatalytic activity for the decomposition of methylene blue.

Multi-Strata Lexikon vs. Constraintranking: Degemination im Deutschen (다층어휘부와 어휘부 대 제약우위도)

  • Yu Si-Taek
    • Koreanishche Zeitschrift fur Deutsche Sprachwissenschaft
    • /
    • v.1
    • /
    • pp.313-348
    • /
    • 1999
  • 이 논문은 독일어의 겹자음회피현상을 설명함에 있어 어휘음운론에서의 분석이 보이는 문제들을 지적하고, 이 문제들이 제약에 바탕을 둔 이론에서는 어떻게 해결될 수 있는가를 보인다. 제약들간의 상호작용에서 특히 중요한 역할을 하는 것이 단일형태실현제약 (Uniform Exponence)으로서, 이 제약을 통해 독일어 동사의 현재시제, 단수, 2인칭 형태와 3인칭형태에서 나타나는 겹자음회피현상이 동사의 어형변화표 (Verbparadigma)와 밀접한 관련이 있음을 알 수 있다. 이는 규칙들을 통해 2인칭과 3인칭의 올바른 형태를 각각 개별적으로 찾아내는 어휘음운론의 분석과는 근본적으로 다르다. 왜냐하면 어휘음운론의 분석에 따를 때, 예를 들어 3인칭 동사 arbeitet에서 Schwa 모음의 삽입은 겹자음회피를 위해 일어난다고 설명되지만 겹자음이 없음에도 불구하고 Schwa 모음이 마찬가지로 삽입되는 2인칭동사 arbeitest는 설명되지 않기 때문이다. 이런 분석에서는 2인칭 형태와 3인칭 형태가 서로 아무런 관련 없이 각기 따로 존재하게된다. 이에 반해 단일형태제약은 이 두개의 형태를 동시에 비교하므로, 동사 굴절형태에서 마치 불필요한 것으로 보이는 모음삽입이나 자음탈락의 원인에 대해 이론적인 근거를 제시할 수 있다. 즉 2인칭 형태와 3인칭 형태는 보다 상위의 제약들이 막지 않는 한 서로 최대한 비슷한 형태를 가지려고 한다. 이 논문은 겹자음 회피를 위한 수단으로서 모음삽입이나 자음탈락은 오로지 이를 통해 동사의 어형변화표가 좋아질 때만 가능하다는 것을 보여줌으로써 규칙이론이 포착하지 못하고 있는 중요한 일반화를 제시하고 있다. 단일형태 실현제약의 중요성은 접두사 in- 과 un- 이 어간과 결합할 때 보이는 대조를 통해서도 확인된다. 여기서도 어휘음운론의 다층어휘부 구조에 의한 설명이 갖는 문제점이 제약들간의 상호작용을 통해 해결될 수 있음을 알 수 있다.VII-1 및 VII-2공의 3600 m 하부층은 건성 가스 생성 단계에까지 도달한 것으로 나타났다. JDZ VII-1, VII-2 시추공의 3500 m 하위 구간의 올리고세 퇴적층에서 유기물 함량 및 수소 지수가 급격히 감소하는 것은 매몰 심도가 깊어지면서 유기물이 열 분해되어 이미 탄화수소를 생성한 것으로 해석된다. JDZ VII-1 및 VII-2 시추공의 가스징후 및 길소나이트 (gilsonite)는 탄화수소가 생성되어 이동한 흔적을 시사한다.을 해석할 수 있음을 보여주는 것으로 평가된다. 다만 PLAYMAKER2가 보다 신뢰할 만한 퇴적환경 해석을 위한 전문가 시스템으로 구축되기 위해서는 향후 많은 퇴적학 전문가들이 추가로 참여하여 기존 규칙들을 재검증하고 새로운 규칙들을 첨가함으로써 보디 세련된 지식베이스를 개발하여야 할 것으로 판단된다.이며 세 개의 산소가 이루는 평면에서 $1.68{\AA}$ 소다라이트내로 이동하여 위치한다. 32개의 $Tl^{+}$ 이온은 결정학적 자리 II에 존재하고 있으며 산소와의 결합거리를 $2.70(1){\AA}$을 유지하면서 큰 동공속으로 $1.48{\AA}$ 이동하여 위치한다. 약 18개의 $Tl^+$ 이온은 결정학적 자리III에, 또 다른 10개의 $Tl^+$ 이온은 결정학적 자리III'에 존재하고 골조 산소와 각각 $2.86(2){\AA},\;2.96(4){\AA}$의 결합거리를 이룬다.

  • PDF

Studies on Ion-Selective Crown Ether Dyes (이온선택성 크라운 에테르 염료에 관한 연구)

  • Sam-Woo Kang;Chong-Min Park;Won-Fae Koo;Keun-Jae Kim;Soo-Min Lee;Choo-Hwan Chang
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.443-451
    • /
    • 1988
  • New crown ether dye-Ⅰ and dye-Ⅱ having an azo group(-N=N-) were synthesized from monobenzo-15-crown-5 and dibenzo-18-crown-6. These dyes showed ${\lambda}_{max}$ of 377 and 383nm respectively. The complexes of alkali metal ions ($Na^+$, $K^+$, $Cs^+$) with dye ligands showed band shift (390~400nm) and intensity increased. For a given anion, the extraction constants are in the order of $K^+$ < $Cs^+$ < $Na^+$ for dye-Ⅰ and $Cs^+$ < $Na^+$ < $K^+$ for dye-Ⅱ. These results show that the selectivity of crown ethers toward the alkali metal ions is dependant on the charge density of cation and the size of crown ether cavity. For a given cation, the order of the extraction constant is $Cl^-$ < $Br^-$ < $I^-$ < picrate. This order coincides with the degree of anion solvation effect.

  • PDF

A study of myopia progression status for a diverse school group (초·중·고 학생들의 근시진행정도에 대한 고찰)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Jung, Ju-Hyun;Ju, Seok-Hui
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • There are reports that the myopia progression have been difference according to myopia degree and age. In this studies, we divided into three investigated groups. The A group is the lower elementary school(50), the B group is the high elementary school(50), the C group is the junior high school(50) and the D group is the high school students(50). The myopia progression have been compared with each group and most variable terms have been investigated. We have analyzed the refraction inspection record that were investigated to put on spectacles in three years(visiting three times or more). The subject of study were 200 persons(men 100, women 100), 1. The distribution of equivalence with ages : A group -2.72D, B group -2.90D, C group -3.53D, D group -3.96D. 2. The pupillary distance have been 57.4mm(A), 59.9mm(B), 61.6mm(C), 63.4mm(D). 3. On a monthly variation : -0.02D(A), -0.045(B), -0.050D(C), -0.025(D) in men, and -0.06D(A), -0.06D(B), -0.045(C), -0.04D(D) in women. 4. After due considering monthly variation and suppose that the variatting times of spectacles degress were time of refracting inspection. The result : 3.6 month for A group, 4.8 month for B group, 5.3 month for C group and 7.7 month for D group.

  • PDF

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

The Study of the Abnormal Refraction Eye of the Primary School Children in Daegu (대구지역 초등학생 굴절이상안에 대한 연구)

  • Kim, Dae Nyoun;Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. the visual acuity test wan performed the object and subject method. The results were follows. 1. The eye types were 94.8% positive for myopia, 1.2% for emmetropia and 4.0% hyperopia, respectively. 2. The abnormal refraction eyes were 71.3% positive for simple myopia, 17.9% for myopic compound astigmatism, 6.9% for myopic simple astigmatism, and 2.5% for simple hyperopia, 0.6%for hyperopic compound astigmatism, 0.8%for hyperopic simple astigmatism, respectively. 3. The axis of astigmatism were 72.8% for astigmatism with-the-rule, 23.2% for astigmatism against-the-rule, 4.0% for astigmatism oblique, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF