• Title/Summary/Keyword: 동공

Search Result 398, Processing Time 0.033 seconds

Dental anomalies associated with Axenfeld-Rieger syndrome (Axenfeld-Rieger 증후군과 연관된 치과적 이상)

  • Kim, Ki-Rim;Lee, Doo-Young;Kim, Seung-Hye;Lee, Sang-Hui;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.6 no.2
    • /
    • pp.94-98
    • /
    • 2010
  • Axenfeld-Rieger syndrome is a rare autosomal dominant disorder characterized by various ocular and extraocular malformations. The incidence of Axenfeld-Rieger syndrome has been estimated to be 1 per 200,000. The syndrome is characterized by short body stature, delayed bone age, and deficient or arrested development of neural crest cells involving the anterior chamber of the eyes, facial bones, teeth, periumbilical skin, and cardiovascular system. This is a case of a 6 year-old girl, who came to the department of the pediatric dentistry, Yonsei University Dental Hospital, for evaluation and treatment of multiple congenital missing permanent teeth. The patient presented typical dental, craniofacial, and systemic features of Axenfeld-Rieger syndrome, such as glaucoma, oval pupil, heterochromatic iris, umbilical hernia, and delayed bone age. On the panoramic view, 3 primary teeth were missing and 13 permanent tooth germs were absent. On the lateral cephalograph, underdevelopment of the maxilla and normal growth pattern of the mandible were confirmed. Periodic dental follow-up is planned for evaluation and interceptive treatment of her dental and craniofacial problems. Denture or removable space maintainer with a pontic is considered for esthetic and functional restoration. In addition, orthognathic surgery is also planned in future to prevent further midfacial skeletal deformation. Early diagnosis of Axenfeld-Rieger syndrome is very important to prevent exacerbation of complications, such as glaucoma and skeletal deformities.

  • PDF

Immunocytochemical Localization of Melanopsin-immunoreactive Neurons in the Mouse Visual Cortex (생쥐 시각피질에서 melanopsin을 가지는 신경세포의 면역조직화학적 위치)

  • Lee, Won-Sig;Noh, Eun-Jong;Seo, Yoon-Dam;Jeong, Se-Jin;Lee, Eun-Shil;Jeon, Chang-Jin
    • Journal of Life Science
    • /
    • v.23 no.6
    • /
    • pp.804-811
    • /
    • 2013
  • Melanopsin is an opsin-like photopigment found in the small proportion of photosensitive ganglion cells of the retina. It is involved in the regulation of the synchronization of the circadian cycle as well as in the control of pupillary light reflex. The purpose of the present study is to investigate whether melanopsin is also expressed in the other areas of the central visual system outside the retina. We have studied the distribution and morphology of neurons containing melanopsin in the mouse visual cortex with antibody immunocytochemistry. Melanopsin immunoreactivity was mostly present in neuronal soma, but not in nuclei. We found that melanopsin was present in a large subset of neurons within the adult mouse visual cortex with the highest density in layer II/III. In layer I of the visual cortex, melanopsin-immunoreactive (IR) neurons were rarely encountered. In the mouse visual cortex, the majority of the melanopsin-IR neurons consisted of round/oval cells, but was varied in morphology. Vertical fusiform and pyramidal cells were also rarely labeled with the anti-melanopsin antibody. The labeled cells did not show any distinctive distributional pattern. Some melanopsin-IR neurons in mouse visual cortex co-localized with nitricoxide synthase, calbindin and parvalbumin. Our data indicate that melanopsin is located in specific neurons and surprisingly widespread in visual cortex. This finding raises the need of the functional study of melanopsin in central visual areas outside the retina.

Precision Improvement Methodology of Geotechnical Information through Outlier Analysis (이상치 분석을 통한 3차원 지반정보 정밀도 향상 방안)

  • Lee, Boyoung;Hwang, Bumsik;Kim, Hansaem;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.2
    • /
    • pp.23-35
    • /
    • 2018
  • Recently, ground disasters such as road collapses and cavities have been frequently occurred in Seoul and downtown areas. As a result, studies on the integrated underground space map is underway as a government's solution. On the other hand, the geotechnical information underlying the integrated underground space map has been being built with more than 220 thousands borehole DB informations through the Integrated DB Center of National Geotechnical Information. To build a three-dimensional integrated underground space map based on the geotechnical information, the reliability of the geotechnical information should be verified by analyzing and evaluating the precision of the geotechnical information. Thereby, studies were conducted on the precision verification and evaluation of the constructed geotechnical information. Thereafter, it has been reviewed how to utilize geotechnical information in addition to analyzing the precision of the geotechnical information in order to visualize three dimensions in geotechnical information. As a further step to the practical DB application, a module is suggested in this study to improve the precision of geotechnical information for establishing reliable three dimensional integrated underground space maps based on the previous research results.

Gaze Tracking System Using Feature Points of Pupil and Glints Center (동공과 글린트의 특징점 관계를 이용한 시선 추적 시스템)

  • Park Jin-Woo;Kwon Yong-Moo;Sohn Kwang-Hoon
    • Journal of Broadcast Engineering
    • /
    • v.11 no.1 s.30
    • /
    • pp.80-90
    • /
    • 2006
  • A simple 2D gaze tracking method using single camera and Purkinje image is proposed. This method employs single camera with infrared filter to capture one eye and two infrared light sources to make reflection points for estimating corresponding gaze point on the screen from user's eyes. Single camera, infrared light sources and user's head can be slightly moved. Thus, it renders simple and flexible system without using any inconvenient fixed equipments or assuming fixed head. The system also includes a simple and accurate personal calibration procedure. Before using the system, each user only has to stare at two target points for a few seconds so that the system can initiate user's individual factors of estimating algorithm. The proposed system has been developed to work in real-time providing over 10 frames per second with XGA $(1024{\times}768)$ resolution. The test results of nine objects of three subjects show that the system is achieving an average estimation error less than I degree.

Convergence study of Comparison of prognosis between Adult and Elderly patients with Traumatic Acute Subdural Hematoma: Retrospective survey research (성인과 노인에서 외상성 급성 경막하 혈종의 예후 비교에 대한 융합적 연구: 후향적 조사 연구)

  • Lee, Seung-Woo;Woo, Sang-Jun;Kim, Eun-A
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.6
    • /
    • pp.411-422
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the prognosis of traumatic acute subdural hematoma between adults and the elderly to provide appropriate nursing according to age. Methods: A retrospective medical records research study was conducted on 239 patients(adults 104, elderly 135) at Gwangju C university hospital. For data analysis, χ2 test, independent sample t-test, one-way ANOVA were used. Results: There was no difference between GCS at discharge(t=-0.03, p=.978) and GOS at discharge(t=0.17, p=.863). But there were differences in gender(χ2=4.19, p=.041), history(χ2=20.78, p<.001), GCS at admission(t=-2.22, p=.028), pupil reflection at admission(t=8.04, p=.005), pH(t=-3.30, p=.001), serum blood glucose(t=-0.85, p=.040), complications(χ2=6.450, p=.011) between adults and elderly. Conculsion: When nursing patients with traumatic acute subdural hematoma, it is thought that patients assessment and nursing care considering the clinical characteristics according to age can be provided. Future research needs to develop educational materials for medical staff.

Development for Multi-modal Realistic Experience I/O Interaction System (멀티모달 실감 경험 I/O 인터랙션 시스템 개발)

  • Park, Jae-Un;Whang, Min-Cheol;Lee, Jung-Nyun;Heo, Hwan;Jeong, Yong-Mu
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.627-636
    • /
    • 2011
  • The purpose of this study is to develop the multi-modal interaction system. This system provides realistic and an immersive experience through multi-modal interaction. The system recognizes user behavior, intention, and attention, which overcomes the limitations of uni-modal interaction. The multi-modal interaction system is based upon gesture interaction methods, intuitive gesture interaction and attention evaluation technology. The gesture interaction methods were based on the sensors that were selected to analyze the accuracy of the 3-D gesture recognition technology using meta-analysis. The elements of intuitive gesture interaction were reflected through the results of experiments. The attention evaluation technology was developed by the physiological signal analysis. This system is divided into 3 modules; a motion cognitive system, an eye gaze detecting system, and a bio-reaction sensing system. The first module is the motion cognitive system which uses the accelerator sensor and flexible sensors to recognize hand and finger movements of the user. The second module is an eye gaze detecting system that detects pupil movements and reactions. The final module consists of a bio-reaction sensing system or attention evaluating system which tracks cardiovascular and skin temperature reactions. This study will be used for the development of realistic digital entertainment technology.

  • PDF

The Character Factor of Myopia by the Living Styles (생활 환경에서 오는 후천적 근시의 성격요인)

  • Kim, Jeong-Sik;Kang, Hywang-Yoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.129-133
    • /
    • 1999
  • For the myopia eyes of the people which are ametropia, the classified distribution has showed % for the simple myopic, 50% for the compound myopic astigmatism, 15% for the simple myopic astigmatism and 19% for the mixed astigmatism. The myopic ametropia for the both eyes has the distribution of 35% for -0.50D~-2.00Dptr, 54% for -2.00~6.00Dptr, and 11% for over -6.00Dptr. The classifying distribution for the age for the myopic ametropia was 54% for 15~20, 22% for 21~40, 14% for 41~60 and 10% for 61. The occupational distribution for the myopic ametropia has showed 61.5% for the student(Middle, High, College), 13.5% for the office worker, and 15% for the house wives as well as the small business. The hour affecting the refraction most for a day was after P.M. 7 which recorded 45% as the highest value. The reason is that the myopia degree decreases in the morning as the cornea flats and the situation is reversed in the afternoon so that there is a difference of Sph -0.50D and as getting darker the refraction degree of the light coming through the enlarged pupil refraction around the cornea is high. For the seasons the highest myopic degree has been recorded for 68% in the summer due to the shortage of nutrition and the climination inside the body by the exhaustion of sweat. In the blood types A and B are distributed closely as 34% and more active man with O has recorded higher myopic degree than woman. However woman showed higher accommodation power than man regardless the blood types. In the characteristic factors of myopic eye, the character feels fatigue easily has showed the distribution for 42% which is the highest and it could be classified largely by two the.

  • PDF

CA/C Ratio of Adults in Their Early Twenties with Normal Binocular Vision (양안시가 정상인 20대 초반 성인의 CA/C비)

  • Lee, Mu-Hyuk;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.153-158
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the convergence accommodation to convergence (CA/C) ratio and to investigate relationships among age, accommodative amplitude and PD (interpupillary distance) of adults in their early twenties with normal binocular vision. Methods: 44 subjects (mean age, $21.75{\pm}1.16$ years) with healthy eyes were examined. The CA/C ratios were measured by using the difference of Gaussian (DOG) target with retinoscopy. Results: The mean CA/C ratio was $0.052{\pm}0.017$ D/$\Delta$. A moderate negative correction was present between CA/C ratio and age (r = -0.50, p = 0.0005), and a highly positive correction was found between CA/C ratio and accommodative amplitude (r = 0.79, p<0.0001). There was no relation between PD and CA/C ratio. Conclusions: The CA/C ratio presented was mean value for adults in their early twenties with healthy eye between 19 and 25 years of age. There was a high correlation between accommodative amplitude and CA/C ratio. Therefore, the CA/C ratio will be useful basic information for comparison in age, gender and binocular anomalies with similar data from other countries.

Micromorphological Characteristics of Buddhist Temple Woods Treated with Eire-retardant (방염 처리 고목재의 미생물 분해의 미시형태적 특징)

  • Wi, Seung Gon;Kim, Ik-Joo;Park, Young Man;Kim, Yoon Soo
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.27-34
    • /
    • 2001
  • Following the recommendations made by the cultural authorities the wooden cultural properties (WCP) had been treated with fire-retardants for fire protection. However, visual inspections of some of the WCPs treated with fire-retardants showed microbial decay. The work was extended to examine the micromorphological characteristics of the WCPs in a Buddhist temple which had been treated with fire-retardant. Microscopic examination showed the presence of typical soft rot cavities along the length of microfibrils in the secondary wall. Bacterial attack was also observed by scanning and transmission electron microscopy. It is interesting that the decay patterns observed in the Buddhist temple were very similar to those observed in the waterlogged woods. Presumably chemicals in the fire-retardants used rendered the wood susceptible to attack by soft-rot and bacterial decay by causing an increase in the moisture content of wood. Further studies are needed to investigate the effect of fire-retardants used currently on the hygroscopicity and the strength of wood materials in the WCPs. Microbial attacks caused degradation of the secondary cell walls and in some cases also of the middle lamella. In addition, the cell walls in the outer parts of wood were also degraded due to weathering, and cell separation occurred from total disintegration of the middle lamella.

  • PDF

The Accommodative Lag and Refractive Error in Early Adults (초년 성인의 굴절이상과 조절래그 분포의 연관성)

  • Baarg, Saang-Bai;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • Purpose: The purpose of this study was to determine the distribution and correlation of accommodative lag with refractive error. Method: We had tested the clinical refraction and the accommodative lag in clinically normal 49 young adults (total 98 eyes) aged 18 to 25 years without abnormal binocular function. Monocular and binocular accommodative lag were tested with 0.50 D cross-cylinder lens and near vision test chart which had cross-hairs after full correction of LogMAR visual acuity over 0.05. Results: There was no statistical differences in monocular accommodative lag between right ($0.64{\pm}0.64$ D) and left eye ($0.63{\pm}0.64$)(p=0.858). The accommodative lag of male was higher than female and the range of the value was broader than female in binocular accommodative lag (p=0.015). The wider the inter-pupillary distance was, the higher the accommodative lag was (p=0.003). However, there were no differences with age (p=0.800) and dominant eye (p=0.402). The ranges of accommodative lag of low, middle, and high myopia were 0.75 ~ -0.25 D, 1.25 ~ -0.50 D, and 1.50 ~ -0.75 D, respectively, and the regression was 'y = -0.03953x+0.09205'. Conclusions: These data suggest that clinically normal young adults with high amounts of refractive error have more variable accommodative lag and increased spherical equivalent refraction.