• Title/Summary/Keyword: 동공크기

Search Result 108, Processing Time 0.031 seconds

Studies on the New Analytical Methods for Separation and Recovery of Rare Earth Metals (I) : Adsorption Characteristics of U(VI) Ion by New Synthetic Resins with Macrocyclic Compounds (희토류금속 분리 및 회수를 위한 분석화학적 연구 (제1보) : 우라늄(VI)의 분리회수를 위한 선택이온교환수지 합성과 우라늄(VI) 금속이온의 흡착특성)

  • Jung Oh Jin;Hak Jin Jung;Joon Tea Kim
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.358-370
    • /
    • 1988
  • Several new ion exchange resins have been synthesized from chloromethyl styrene-1,4-divinylbenzene(DVB) with 1%, 2%, 4%, and 10%-crosslinking and macrocyclic ligands of cryptand type by interpolymerization method. The adsorption characteristics and the pH, time, solvents and concentration dependence of the adsorption of metal ions by this resin were studied. The correlation between the separation characteristics of uranium, rare earths and transition metal on the resins and the stability constants of complexes with macrocyclic ligands have been examined. The resins were very stable in both acidic and basic media and have good resistance to heat at $280^{\circ}C$. The $UO_2^{+2}$ aqueous solution are not adsorbed on the resins below pH 3.0, but the power of adsorption of $UO_2^{2+}$ increased rapidly above pH 4.0. The optimum equilibrium time for adsorption of metallic ions was twenty minutes and adsorptive power decreased in proportion to crosslinking size of the resins and order of dielectric constants of solvents used and the selective sequence for metal cations is in the order of $UO_2^{2+},\;Cu^{2+}\;and\;Nd^{3+}$.

  • PDF

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Optical Performance Analysis of the Eye which it Follows in Iris Eccentricity (홍채 편심에 따른 눈의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.31-34
    • /
    • 2009
  • Purpose: We are to analyze optically how to affect the eye related with movement of the iris. Methods: Using the schematic eye to have the crystalline lens of the radial GRIN and the spherical GRIN forms that come to be planned in existing, the iris centre was moved 0.5 mm with nasal direction in order to be identical with the real eye. Also, considering that the iris centre move according to increase of the pupil size, the iris centre was moved 0.4 mm with temporal direction to analyze the optical performance change of the eye respectively. Results: Because of decrease in the spherical aberration, the schematic eye with nasal direction 0.5 mm eccentricity of the iris showed a different consequence plentifully compared with the performance of the real eye. Besides, the schematic eye with temporal direction 0.4 mm eccentricity of the iris showed that the spherical aberration somewhat increased. Conclusions: In case of design of the schematic eye with the similar real eye performance which the iris centre was moved 0.5 mm with nasal direction, we need to research about aspheric coefficient of optical constants of each refracting surface considering the performance change of a spherical aberration, a peripheral power error and astigmatism etc, owing to change of the real eye hence to be affected by the iris movement.

  • PDF

Macrocyclic Complexes of Actinide and Lanthanide Metals (Ⅰ). Formation and Properties of Cation Complexes with Macrocyclic Ligands (악틴 및 란탄족금속의 거대고리 착물 (제 1 보). 거대고리 리간드의 금속착물의 형성과 성질)

  • Jeong, O Jin;Choe, Chil Nam;Yun, Seok Jin;Son, Yeon Su
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.143-158
    • /
    • 1990
  • Metal complexes were prepared by reacting uranium (Ⅵ), thorium (Ⅳ) and rare earth metal (Ⅲ) ions including Nd (Ⅲ), Sm (Ⅲ) and Ho (Ⅲ) with macrocyclic ligands including five crown ethers, nine crownands and one cryptand ligands, and subjected to NMR studies in order to examine coordination sites of the ligands and compositions of the complexes formed. Among the marcocyclic ligands, crown ethers and crownand ligands have shown down-field shifts of the methylene protons of the lcigands by forming stable complexes with all the metal ions and the differences of chemical shifts were decreased as increasing of the cavity-size of crown ethers for the same metal ions and decreasing of the atomic number of the rare earth metals for the same ligands. It has been found that crownand 22 gave a stable complex with uranium(Ⅵ) ion by the coordination through both oxygen and nitrogen atoms of the ligand whereas no complex was formed with the rare earth metal(Ⅲ) ions, which on the other hand were found to form stable complexes with cryptand 221. The rest of the crowand ligands have also been found to form stable complexes with uranium(Ⅵ) ion by coordinating through all the oxygen and nitrogen atoms of the ligands whereas no complexes were formed with the rare earth metal(Ⅲ) ions. It has also been shown by 1H-NMR study that uranium(Ⅵ), thorium(Ⅳ) and rare earth metal(Ⅲ) ions formed 1:1 complexes with the macrocyclic ligands except for thorium(Ⅳ) complex of 12C4 in which the mole ratio of metal to ligand is 1:2. More stable metal complexes show larger changes in chemical shifts of the coordinated ligand protons. Finally, the rare earth metal(Ⅲ) complexes of 18C6 have shown ligand exchange reaction with the solvent molecules in acetylacetone solution, which was not observed for the uranium (Ⅵ) complexes.

  • PDF

A Study on Wafer-Level 3D Integration Including Wafer Bonding using Low-k Polymeric Adhesive (저유전체 고분자 접착 물질을 이용한 웨이퍼 본딩을 포함하는 웨이퍼 레벨 3차원 집적회로 구현에 관한 연구)

  • Kwon, Yongchai;Seok, Jongwon;Lu, Jian-Qiang;Cale, Timothy;Gutmann, Ronald
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.466-472
    • /
    • 2007
  • A technology platform for wafer-level three-dimensional integration circuits (3D-ICs) is presented, and that uses wafer bonding with low-k polymeric adhesives and Cu damascene inter-wafer interconnects. In this work, one of such technical platforms is explained and characterized using a test vehicle of inter-wafer 3D via-chain structures. Electrical and mechanical characterizations of the structure are performed using continuously connected 3D via-chains. Evaluation results of the wafer bonding, which is a necessary process for stacking the wafers and uses low-k dielectrics as polymeric adhesive, are also presented through the wafer bonding between a glass wafer and a silicon wafer. After wafer bonding, three evaluations are conducted; (1) the fraction of bonded area is measured through the optical inspection, (2) the qualitative bond strength test to inspect the separation of the bonded wafers is taken by a razor blade, and (3) the quantitative bond strength is measured by a four point bending. To date, benzocyclobutene (BCB), $Flare^{TM}$, methylsilsesquioxane (MSSQ) and parylene-N were considered as bonding adhesives. Of the candidates, BCB and $Flare^{TM}$ were determined as adhesives after screening tests. By comparing BCB and $Flare^{TM}$, it was deduced that BCB is better as a baseline adhesive. It was because although wafer pairs bonded using $Flare^{TM}$ has a higher bond strength than those using BCB, wafer pairs bonded using BCB is still higher than that at the interface between Cu and porous low-k interlevel dielectrics (ILD), indicating almost 100% of bonded area routinely.

Application Strategies of Eye-tracking Method in Nightscape Evaluation (야간경관 평가에서의 아이트래킹 분석 적용 연구)

  • Kang, Youngeun;Kim, Mintai
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.87-97
    • /
    • 2015
  • There's a trend towards vitalization of nightscape planning businesses nationally and locally as well for city image making and activation of regional economy, but there is still no systematic nightscape planning going on for lack of relevant researches and objective evaluations. This study aims to suggest the guideline for nightscape planning by conducting an eye tracking experiment and survey for recognizing the characteristics of a nightscape. Furthermore, the authors intended to verify the eye-tracking method as a tool for landscape evaluation. The research site was restricted in the campus of Virginia Tech, VA, and those were selected by experts' survey among various types of nightscape images. The variables for analyzing the characteristics of nightscape images selected were 'preference', 'safety(fear)' and 'clearness'. 'Fixation duration', 'saccade duration', 'scan path length', and 'pupil size' were selected as the eye movement measurements. The results of this study are as follows: The first outcome found was that there were significant differences among the characteristics(preference, safety and clearness) of a nightscape by MANOVA, and these variables were correlated positively by Pearson's correlation. Secondly, there were differences on fixation duration, saccade duration and scan path depending on the nightscape setting statistically. Also, the eye tracking measurement in an open setting was recorded lower than enclosed settings. In the result of a heat map, we found the meaning of the fixated areas on both viewing without intention and viewing intentionally. It turned out that the fixated areas were consistent with the areas the subjects felt preferred and clarity in all of the nightscape images, which means people usually focus on what they prefer and see clearly in a certain nightscape. Based on this result and previous studies, the authors could make a conclusion that eye tracking method can apply to evaluate nightscape settings in terms of analyzing the whole characteristics and finding specific points for the detailed analysis as well. Therefore, these results can contribute by suggesting nightscape planning, implication of the landscape evaluation, and implication of the eye tracking study.

Clinicoradiologic Characteristics of Intradural Extramedullary Conventional Spinal Ependymoma (경막내 척수외 뇌실막세포종의 임상 영상의학적 특징)

  • Seung Hyun Lee;Yoon Jin Cha;Yong Eun Cho;Mina Park;Bio Joo;Sang Hyun Suh;Sung Jun Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1066-1079
    • /
    • 2023
  • Purpose Distinguishing intradural extramedullary (IDEM) spinal ependymoma from myxopapillary ependymoma is challenging due to the location of IDEM spinal ependymoma. This study aimed to investigate the utility of clinical and MR imaging features for differentiating between IDEM spinal and myxopapillary ependymomas. Materials and Methods We compared tumor size, longitudinal/axial location, enhancement degree/pattern, tumor margin, signal intensity (SI) of the tumor on T2-weighted images and T1-weighted image (T1WI), increased cerebrospinal fluid (CSF) SI caudal to the tumor on T1WI, and CSF dissemination of pathologically confirmed 12 IDEM spinal and 10 myxopapillary ependymomas. Furthermore, classification and regression tree (CART) was performed to identify the clinical and MR features for differentiating between IDEM spinal and myxopapillary ependymomas. Results Patients with IDEM spinal ependymomas were older than those with myxopapillary ependymomas (48 years vs. 29.5 years, p < 0.05). A high SI of the tumor on T1W1 was more frequently observed in IDEM spinal ependymomas than in myxopapillary ependymomas (p = 0.02). Conversely, myxopapillary ependymomas show CSF dissemination. Increased CSF SI caudal to the tumor on T1WI was observed more frequently in myxopapillary ependymomas than in IDEM spinal ependymomas (p < 0.05). Dissemination to the CSF space and increased CSF SI caudal to the tumor on T1WI were the most important variables in CART analysis. Conclusion Clinical and radiological variables may help differentiate between IDEM spinal and myxopapillary ependymomas.