• Title/Summary/Keyword: 동공중심간거리

Search Result 13, Processing Time 0.024 seconds

A Study on Improvement and Problem of Ready-made Reading Spectacles (상품화된 근용안경의 문제점 및 개선 방안에 관한 연구)

  • Lee, Hark Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.85-91
    • /
    • 1996
  • This is a study of the measurement of inter papillary constance (P.D) in 702 old aged farmers (aged over 45) and the comparision of frame size and distance space of optical center (O.C) from 240 Ready-made Reading spectacles. The average of P.D in male (62.83mm) is greater than in female (61.18mm), and the O.C of Ready-made Reading spectacles of Plastic lens (71.2mm) longer than glass lens (70.8mm). The correction prism power by wearing Reading spectacles in male was 0.7prism to 3.6prism and in female was 0.9prism to 4.4prism. So the prism power in female is greater than in male.

  • PDF

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center (안경 광학중심과 동공중심의 불일치에 의한 수평, 수직 유발프리즘의 측정)

  • Kim, Hyojin;Park, Jee-Hyun;Park, Seon-A;Baek, Ji-Seon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Measurement of the horizontal and vertical prism diopter was investigated which was occurred due to distance differences between the optical inter-centeral distance (OC) and the interpupillary distance (PD) of the prescribed glasses. Methods: We surveyed 96 subjects (192 eyes) at the average age of 21.56 years old. The PD was measured by using the PD measurement system (DONGYANG PD-85, Korea), and the OC of the glasses was measured by using the projective peak refractive power measurement system (TOPCON CL-200, Japan). The OH value was measured by using Penlight and the PD ruler. Results: The PD which had been measured by the PD system and the OC of the glasses revealed 78.1% of differences. 62.5% of the objects were base-in value prescribed glasses; 58.3% were out of permissible error. Only 8 subject showed concurrence between the prescribed glasses and the OH value, and 82.3% of the objects were induced vertical prism of over 1 (prism diopter). Conclusions: In order to improve the vision function of people who wear glasses, it is necessary to advance the accuracy of PD, OH measurement and making glasses as well.

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

Eye Detection Method Using Geometrical Features Between Eyebrows and Eyes in Smart Phone (스마트 폰에서 눈썹과 눈 간의 기하학적 특성을 이용한 눈 검출 방법)

  • Oh, Woongchun;Kang, Teaho;Kwak, Noyoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.11a
    • /
    • pp.41-44
    • /
    • 2014
  • 본 논문은 안드로이드 스마트 폰 환경에서 정중앙 블록과 주변 블록들 간의 블록 대비도를 이용해 눈썹을 검출한 후, 눈썹과 눈 간의 기하학적 특성을 이용해 눈의 위치를 찾는 눈 검출 방법에 관한 것이다. 제안된 방법은 Haar-like 특징과 AdaBoost 알고리즘 그리고 적응형 템플릿 정합을 이용해 입력 영상에서 얼굴 영역을 검출한 후, 이를 이용해 좌측 및 우측 눈썹과 눈 탐색 영역을 산정한다. 눈썹 영역의 Integral Image에서 눈썹에 해당하는 부분이 주변 블록들에 비해 상대적으로 어둡다는 특성을 이용해 눈썹을 추출한다. 이와 동시에 각 눈 탐색 영역의 Integral Image에서 동공 블록이 나머지 주변 블록들에 비해 상대적으로 어둡고 대칭성이 양호하다는 특성을 이용해 눈 후보 영역들을 추출한 후 최대 블록 대비도를 갖는 블록의 중심화소를 동공 후보점으로 삼는다. 이후 눈의 위치는 항상 눈썹 하단에 위치하며 그 떨어진 정도가 사람마다 크게 다르지 않다는 기하학적 특성을 이용해 눈 후보 영역에서 나온 동공 후보 점들을 검증한다. 제안된 방법은 거리 및 조명 변화 그리고 안경 착용에 강인한 것이 장점이다. 눈썹을 먼저 찾은 후 기하학적 특성을 이용해 좌우 동공 후보점 쌍의 적합성을 검증함으로써 안경과 눈을 효과적으로 구분할 수 있고 눈이 감겨 동공이 가려진 상태에도 감긴 눈의 위치를 검출할 수 있다.

  • PDF

A Comparative Study on the Ametropias of Philippines and Koreans (한국인과 필리핀인의 굴절이상에 대한 연구)

  • Lee, Hark-Jun;Kwen, Man-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.477-482
    • /
    • 2012
  • Purpose: This study is aimed at finding the conditions of ametropia of adults in the Philippines and the South Korean. Methods: The study objects were 7,695(15,390 eyes) Koreans and 2,256(4,512 eyes) Philippines who visited optic clinics and took refraction test. The distributions of their hypermetropias and myopias about astigmatisms were examined, using the method of equivalent spherical power. When astigmatisms were marked in S-C, cylinder lens diopter and astigmatism axis, presbyopic additions and pupillary distances were analyzed by comparison respectively. Results: Among ametropias of Koreans myopias and hypermetropias were 93.69% and 6.31% respectively and about ametropias of Philippines myopia and hypermetropias were 73.43% and 26.57% respectively. As for spherical equivalent power about Koreans, the results showed that Koreans marked -3.352 D about myopia and Philippines marked -2.213 D about it. There is a gap of -1.139 D between them. About hypermetropia Koreans marked 1.147 D and Philippines, 1.251 D and their gap is 0.104 D. As for ametropia of Koreans there is 49.86% in middle myopia, 32.28% about low myopia, 11.55% about high myopia, and 5.54% about low hypermetropia, 0.75% about middle hypermetropia. As for it about Philippines there is 44.53% in low myopia, 25.11% about middle myopia, 3.79% high myopia and 23.03% low hypermetropia, and 3.51% low hypermetropia respectively. As for cylinder lens there is differences of 0.194 D and 0.22 D between Korean and Philippine for both sexes. Totally Koreans have higher cylinders of 0.175 D than Philippines. As for astigmatism, Koreans have direct astigmatism, inverse astigmatism, and oblique astigmatism in their suffering sequence. As for Philippines, they have direct astigmatism, inverse stigmatism, and oblique astigmatism in their abnormal sequence, and they have higher oblique stigmatism than Koreans. As for presbyopic addition, Philippines have higher distributions than Koreans, and 0.296 D is higher in average. As for pupillary distance, Koreans have longer distance of 0.97 mm in man and 0.63 mm in women than Philippines. Conclusions: As for ametropia, Koreans and Philippines have more myopias than hypermetropias, but Philippines have more rates of hypermetropias than Koreans. And Philippines have more presbyopic additions. Koreans have higher morbidity of inverse astigmatism, and Philippines have higher morbidity of oblique astigmatism comparatively. As for pupillary distance, Koreans have longer length in the body characteristics. This shows that geographical circumstances have much to do with refraction conditions of eyes.

Comparative Study on Growth Stage Aging Changes of The Right and Left Eye Size in Korean (성장기 연령 변화에 따른 좌우안 크기 변화 비교 연구)

  • Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.209-216
    • /
    • 1998
  • The purpose of this study was to compare the right and left eye size, distance between two eyes, interpupillary distance on growth stage aging changes in Korean. The author divided into 5 groups according to subject's age(group A : 7~12 years, group B : 13~15 years, group C : 16~18 years, group D : 19~24 years, group E : 25~30 years). The high values of inter outer canthal distance(T) and distance between two eyes(G) were 94.30 mm, 36.66 mm at group B respectively. The ratio of identical eye size was about 10.0% in A, B, C group but 22.7% in E group. P[T-(right eye size + left eye size) / 2] was wider than IPD. Data showed that the difference was 5.72 mm in group B and 1.13 mm in group E. The reason for this is that the pupils are displaced nasally from the center of the limbal ring. This has significant meaning in ophthalmic procedures.

  • PDF

A Study on the Ametropia in Asian Population (아시아 동양인들의 비정시에 관한 연구)

  • Lee, Young-Il;Hong, Jin Seok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2008
  • Purpose: This study was to investigate the refractive state of an asian population (male: 39, female: 53) from 21 to 30 years old who visited the A optical shop at jongnogu in seoul. Methods: The visual acuity test was performed by the object and subject method. Results: Among the 184 eyes, myopia is 83.16% and emmetropia is 16.84%, respectively. As for the equivalent spheric power of myopic abnormal refractive eyes, the -m0.5Dt < spheric equivalent ${\leq}$ -2.00Dt was 40.53%, the -2.00Dt < spheric equivalent ${\leq}$ -6.00Dt was 51.63% and anything over the -6.00Dt was 7.85%. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 46.67%, 35.56% and 7.77%, respectively. The average of pupillary distance in male (64.5${\pm}$2.9 mm) was greater than that in female (61.9${\pm}$2.3 mm). Conclusions: Korean opticians were provided some useful information about making up a prescription by this research.

  • PDF

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.