• Title/Summary/Keyword: 동결 기온

Search Result 49, Processing Time 0.03 seconds

Experimental Study on Internal Temperature Change Induced by Heating Element Attached to Tunnel Lining Surface (터널 라이닝 표면에 부착된 발열체로 인한 내부 온도 변화의 실험적 연구)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.11
    • /
    • pp.35-40
    • /
    • 2017
  • The rearside of concrete lining of tunnels constructed in cold region might experience on freezing due to the low temperature. This causes damage of concrete lining resulting in adverse affect on the durability as well as integrity of tunnel structure by causing damage to the concrete lining. In order to prevent the rearside of tunnel lining from freeing, the temperature change inside the concrete lining was measured by attaching a heating element to the tunnel lining surface and generating heat for a certain period of time. A special freezing chamber was developed to conduct the experiments considering in-situ environment. The carbone nanotube (CNT) was used as a heating element in this study. The temperature distribution of the concrete lining was measured by applying the heat to the heating element. The effect of the outside temperature and heating duration were analyzed.

Field Test of Tunnel Lining Temperature Variation due to Heating Element Attached to Tunnel Lining Surface (터널라이닝 표면에 부착된 발열체로 인한 라이닝의 온도변화 현장실험)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.4
    • /
    • pp.17-21
    • /
    • 2019
  • In the cold region, the frozen damages in highway tunnels and regular road tunnels have widely been investigated and reported, but the measurement has not been sufficient made. The average temperature in cold region is below the zero, resulting in that the damage due to freezing at the entrance/exit of tunnel is more severe than in the middle of tunnel. In this study, a heating element was developed to prevent the tunnel lining from being frozen by enforcing to increase the temperature of tunnel lining. Then field tests using the developed heating element were performed and it was ensured that the temperature of tunnel lining increased after a certain time.

Development of an AI-based Early Warning System for Water Meter Freeze-Burst Detection Using AI Models (AI기반 물공급 시스템내 동파위험 조기경보를 위한 AI모델 개발 연구)

  • So Ryung Lee;Hyeon June Jang;Jin Wook Lee;Sung Hoon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.511-511
    • /
    • 2023
  • 기후변화로 동절기 기온 저하에 따른 수도계량기의 동파는 지속적으로 심화되고 있으며, 이는 계량기 교체 비용, 누수, 누수량 동결에 의한 2차 피해, 단수 등 사회적 문제를 야기한다. 이와같은 문제를 해결하고자 구조적 대책으로 개별 가정에서 동파 방지형 계량기를 설치할 수 있으나 이를 위한 비용발생이 상당하고, 비구조적 대책으로는 기상청의 동파 지도 알림 서비스를 활용하여 사전적으로 대응하고자 하나, 기상청자료는 대기 온도를 중심으로 제공하고 있기 때문에 해당서비스만으로는 계량기의 동파를 예측하는데 필요한 추가적인 다양한 변수를 활용하는데 한계가 있다. 최근 정부와 공공부문에서 22개 지역, 110개소 이상의 수도계량기함내 IoT 온도센서를 시범 설치하여 계량기 함내의 상태 등을 확인할 수 있는 사업을 수행했다. 전국적인 계량기 상태의 예측과 진단을 위해서는 추가적인 센서 설치가 필요할 것이나, IoT센서 설치 비용 등의 문제로 추가 설치가 더딘 실정이다. 본 연구에서는 겨울 동파 예방을 위해 실제 온도센서를 기반으로 가상센서를 구축하고, 이를 혼합한 하이브리드 방식으로 동파위험 기준에 따라 전국 동파위험 지도를 구축하였다. 가상센서 개발을 위해 독립변수로 위경도, 고도, 음·양지, 보온재 여부 및 기상정보(기온, 강수량, 풍속, 습도)를 활용하고, 종속변수로 실제 센서의 온도를 사용하여 기계학습 모델을 개발하였다. 지역 특성에 따라 정확한 모델을 구축하기 위해 위치정보 및 보온재여부 등의 변수를 활용하여 K-means 방법으로 군집화 하였으며, 각 군집별로 3가지의 기계학습 회귀모델을 적용하였다. 최적의 군집 수를 검토한 결과 4개가 적정한 것으로 판단되었다. 군집의 특성은 지역별 구분과 유사한 패턴을 보이며, 모든 군집에서 Gradient Boosting 회귀모델을 적용하는 것이 적합한 것으로 나타났다. 본 연구에서 개발한 모델을 바탕으로 조건에 따라 동파 예측 알람서비스에 실무적으로 활용할 수 있도록 양호·주의·위험·매우위험 총 4개의 기준을 설정하였다. 실제 본 연구에서 개발된 알고리즘을 국가상수도정보 시스템에 반영하여 테스트 수행중에 있으며, 향후 지속 검증을 할 예정에 있다. 이를 통해 동파 예방 및 피해 최소화, 물절약 등 직간접적 편익이 기대된다.

  • PDF

The Frost Heaving Susceptibility Evaluation of Subgrade Soils Using Laboratory Freezing System (실내 동상시스템을 이용한 노상토의 동상민감성 평가)

  • Shin, Eun Chul;Ryu, Byung Hyun;Park, Jeong Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.2
    • /
    • pp.13-23
    • /
    • 2013
  • The Korean Peninsula is considered as a seasonal frozen area that is thawed in the spring and frozen in the winter. The influence of fines of the frost susceptibility of subgrade soils were established by laboratory freezing tests simulating closely the thermal conditions in the field. During the winter season, the climate is heavily influenced by the cold and dry continental high pressure. Because of siberian air mass, the temperature of January is $-6{\sim}-7^{\circ}C$ on average. This chilly weather generate the frost heaving by freezing the moisture of soil and damage potential of the geotechnical structure. In the freezing soil, the ice lenses increase the freeze portion of soil by absorbing the ground water with capillary action. However, the capillary characteristics differ from the sort of soil on the state of freezing condition. In this study, ten soil samples are prepared. The basic physical property tests were performed by following the Korean Industrial Standard and the soil specimens were classified by the Unified Soil Classification System (USCS). These classified soils are used to perform the laboratory opened systems freezing test in order to determine the frost heaving characteristics of soils such as unfrozen water content, heaving amount, and freezing depth.

Change Projection of Extreme Indices using RCP Climate Change Scenario (RCP 기후변화시나리오를 이용한 극한지수 변화 전망)

  • Jeung, Se-Jin;Sung, Jang Hyun;Kim, Byung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1089-1101
    • /
    • 2013
  • The study uses a regional climate model to check future changes in extreme climate, to calculate extreme indexes presented by STARDEX, and to analyze the trends to predict the continuity and changes in the spatial distribution of extreme climate in the future. An analysis of extreme climate indices showed that they are likely to increase in the Seoul metropolitan area, in Gyeonggi-do, in Yongdong in Gangwon-do, and in the southern shore region of Korea. It is, however, forecasted to diminish in the central inland region. The analysis also showed that the average temperature in Korea will increase because of climate change. On the other hand, an analysis of extreme rainfall indexes showed that the trend of heavy rainfall threshold is 0.229 in Seogwipo, the greatest five-day rainfall is 5.692 in Seogwipo, and the longest dry period is 0.099 in Sokcho. Of extreme temperature indexes, the trend of Hotdays threshold is 0.777 in Incheon and the longest heat wave is 0.162 in Uljin. The Coldnight threshold is 0.075 in Inje and -0.193 in Tongyeong, according to the analysis.

On the Change of Extreme Weather Event using Extreme Indices (극한지수를 이용한 극한 기상사상의 변화 분석)

  • Kim, Bo Kyung;Kim, Byung Sik;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.41-53
    • /
    • 2008
  • Unprecedented weather phenomena are occurring because of climate change: extreme heavy rains, heat waves, and severe rain storms after the rainy season. Recently, the frequency of these abnormal phenomena has increased. However, regular pattern or cycles cannot be found. Analysis of annual data or annual average data, which has been established a research method of climate change, should be applied to find frequency and tendencies of extreme climate events. In this paper, extreme indicators of precipitation and temperature marked by objectivity and consistency were established to analyze data collected by 66 observatories throughout Korea operated by the Meteorological Administration. To assess the statistical significance of the data, linear regression and Kendall-Tau method were applied for statistical diagnosis. The indicators were analyzed to find tendencies. The analysis revealed that an increase of precipitation along with a decrease of the number of rainy days. A seasonal trend was also found: precipitation rate and the heavy rainfall threshold increased to a greater extent in the summer(June-August) than in the winter (September-November). In the meanwhile, a tendency of temperature increase was more prominent in the winter (December-February) than in the summer (June-August). In general, this phenomenon was more widespread in inland areas than in coastal areas. Furthermore, the number of winter frost days diminished throughout Korea. As was mentioned in the literature, the progression of climate change has influenced the increase of temperature in the winter.

Long-term Variation of the Freezing Climate near the Han River and Seoul in Korea (서울 관측소와 한강 결빙 기후의 장기 변동)

  • Oh, Su-Bin;Byun, Hi-Ryong
    • Journal of the Korean earth science society
    • /
    • v.32 no.7
    • /
    • pp.761-769
    • /
    • 2011
  • Daily minimum temperature and freezing data of the Seoul weather station ($37^{\circ}$34'N, $126^{\circ}$57'E, Songwol-dong Jongno-gu Seoul, hereinafter Songwol) and freezing data of the Han River station ($37^{\circ}$30'N, $126^{\circ}$57'E, hereinafter Han River) were used to study the long-term variation of the freezing climate for Seoul, Korea, for the period of 100 years from 1907 to 2006. 'Freezing' of Songwol is defined that the water in outdoor fields is frozen, and 'freezing' of the Han River located 6 km away from Songwol is defined as the region 100 meters upstream of the second and fourth piers in the south end of the Han River Bridge is fully frozen. The mean first freezing date for Songwol was October 28, and one for Han River was December 28; these showed a late tendency, with the rate of 0.78 days $decade^{-1}$ and 3.47 days $decade^{-1}$, respectively. The mean annual freezing days was 159.06 days for Songwol and 50.33 days for Han River; each showed a $decade^{-1}$shorter tendency, with rates of 2.01 days $decade^{-1}$ and 5.24 days $decade^{-1}$, respectively. All the seven no-freezing years (1960, 1971, 1972, 1978, 1988, 1991, and 2006) for Han River came after 1950. The mean daily minimum temperatures of the first freezing dates for Songwol and Han River were $0.55^{\circ}C$ and $-12.22^{\circ}C$. The first freezing occurred after 6.43 days for Songwol and after 8.94 days for Han River with daily minimum temperature below $0^{\circ}C$. The annual minimum temperatures of Songwol and Han River exhibited positive correlations with the first freezing date and negative correlations with freezing days. The result shows that the freezing climate change is relevant to temperature change and is a part of overall climate change. By conducting additional studies with various methods and wider region, we will be able to monitor the freezing climate.

Heat Transfer Test of Tunnel Lining with Heat Insulation (단열재 적용에 따른 터널 라이닝 열전달량 시험)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.7
    • /
    • pp.5-12
    • /
    • 2017
  • The surface of the tunnel lining issues various problems such as cracks due to the cold weather. It is necessary to reduce the recovery costs by means of developing new recovery techniques. However, the research on reducing the damage of road tunnel lining caused by cold weather has not actively been conducted. Hence, this paper analyzes the effectiveness of using insulating materials such as aerogel and heat insulating liquid in enhancing insulating capability. The results show that these materials are effective in reducing heat transfer, confirming damage reduction in cold weather.

An Experimental Study for the Effective Use Scheme of Snow Removal Materials on Road (도로 제설재의 효과적 사용방안에 관한 실험적 연구)

  • Do, Jongnam;Kim, Taesoo;Lee, Chanbok;Kim, Yeonjoong;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.2
    • /
    • pp.5-17
    • /
    • 2012
  • The amount of snow due to global warming and climate change has recently increased. The effective management of snow removal materials will be required. First, on the basis of domestic winter temperature, it is not necessary to get a baseline to less than the freezing point of $-52^{\circ}C$ for the calcium chloride($CaCl_2$) of 30%.. In terms of cost comparison between calcium chloride($CaCl_2$) and sodium chloride($NaCl$), the calcium chloride($CaCl_2$) is 2 to 3 times more expensive, and the supply of the calcium chloride($CaCl_2$) is not produced in domestic country and is in the conditions that have to imports all needed. Accordingly, the effective use scheme of snow removal materials should be considered to multifaceted ways. Thus, the objective of this study is to develop effective method and to replace from calcium choride($CaCl_2$) to sodium chloride($NaCl$) solution in the current snow removal operating system that uses a pre-wetted salt spreading method. The effective method that equals to the quality of the existing snow removal materials was developed in this study through performance tests for deicing chemicals, corrosion test of steel and freezing and thawing tests of concrete.

Deterioration and Microclimate in the Shelter for the Gaetaesajiseokbulibsang (Standing Triad Buddha Statues in Gaetaesaji Temple Site), Nonsan, Korea (논산 개태사지석불입상의 손상도와 보호각 내부의 미기후 환경)

  • Kim, Ji-Young;Park, Sun-Mi;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.179-196
    • /
    • 2009
  • The Gaetaesajiseokbulibsang (Treasure No. 219) consists of light gray and coarse to medium-grained granodiorite with feldspar phenocrysts in part. Magnetic susceptibility of the rock material was measured as 12.06(${\times}10^{-3}$ SI unit), being different from the granite($0.19{\times}10^{-3}$ SI unit) in the Mt. Cheonho. This indicates the raw material has been supplied from the outside. As a result of deterioration assessment, exfoliation of the Right Buddha, cement and dust of the Main Buddha were estimated as 35.2%, 21.1% and 25.0%. The ultrasonic velocity was measured as 2850.2m/s(Main Buddha), 2648.4m/s(Left Buddha) and 2644.5m/s(Right Buddha). The compressive strength calculated from the velocity showed low in the Right Buddha among three and the all pedestal parts which corresponds to the result of deterioration assessment. The indoor mean temperature and relative humidity of the shelter were $13.7^{\circ}C$ and 79.0%. It is evaluated that the indoor microclimate was stable and the shelter functioned to reduce climatic fluctuation of the outdoor. However, water condensation was occurred on the surface of the pedestal part during spring and summer, and freezing in winter season might also be done. These factors were probable to be a main cause of the surface exfoliation of the Triad Buddha Statues. Therefore, dehumidification and heating system in the shelter should be applied to prevent further deterioration.

  • PDF