• Title/Summary/Keyword: 도플러효과

Search Result 227, Processing Time 0.034 seconds

ICI and Compensation Algorithm against Frequency Offset and Phase Noise in SC-FDMA System with Comb Type Pilot (Comb Type 파일럿을 갖는 SC-FDMA에서 주파수 옵셋과 위상 잡음에 의한 ICI와 보상 알고리즘)

  • Ryu, Sang-Burm;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.399-407
    • /
    • 2010
  • SC-FDMA system uses DFT-spreading method for reducing the PAPR of OFDM signal, which improves the power efficiency. Block type pilot is used in SC-FDMA system. However, there are ICI due to the inevitable phase noise and frequency offset that can be generated from the Doppler frequency and inaccuracy between the transceiver oscillators. This ICI definitely degrades the BER performance. To overcome this problem and estimate the channel efficiently, we like to propose ICI compensation algorithm for the SC-FDMA system with comb type pilot. SLM method is additionally included for the PAPR reduction when pilot is assigned in comb type. Finally, it is confirmed that the ICI due to the phase noise and frequency offset is efficiently compensated by the suggested algorithm.

The Effect of Ginkgo Biloba Extract on the Fractionsted Radiation Therapy in C3H Mouse Fibrosarcoma (Ginkgo Biloba Extract가 C3H 마우스 섬유육종의 분할 방사선치료에 미치는 영향)

  • Kim, Jong-Hoon;Ha, Sung-Whan;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 2002
  • Purpose : A ginkgo biloba extract (GBE) has been known as a hypoxic cell radiosensitizer. Its mechanisms of action are increase of the red blood cell deformability, decrease the blood viscosity, and decrease the hypoxic cell fraction in the tumor. The aims of this study were to estimate the effect of GBE on fractionated radiotherapy and to clarify the mechanism of action of the GBE by estimating the blood flow in tumor and normal muscle. Materials and Methods : Fibrosarcoma (FSall) growing in a C3H mouse leg muscle was used as the tumor model. When the tumor size reached 7 mm in diameter, the GBE was given intraperitoneally at 1 and 25 hours prior to irradiation. The tumor growth delay was measured according to the various doses of radiation (3, 6, 9, 12 Gy and 15 Gy) and to the fractionation (single and fractionated irradiation) with and without the GBE injection. The radiation dose to the tumor the response relationships and the enhancement ratio of the GBE were measured. In addition, the blood flow of a normal muscle and a tumor was compared by laser Doppler flowmetry according to the GBE treatment. Results : When the GBE was used with single fraction irradiation with doses ranging from 3 to 12 Gy, GBE increased the tumor growth delay significantly (p<0.05) and the enhancement ratio of the GBE was 1.16. In fractionated irradiation with 3 Gy per day, the relationships between the radiation dose (D) and the tumor growth delay (TGD) were TGD $(days)=0.26{\times}D$ (Gy)+0.13 in the radiation alone group, and the TGD $(days)=0.30{\times}D$ (Gy)+0.13 in the radiation with GBE group. As a result, the enhancement ratio was 1.19 ($95\%$ confidence interval; $1.13\~1.27$). Laser Doppler flowmetry was used to measure the blood flow. The mean blood flow was higher in the muscle (7.78 mL/100 g/min in tumor and the 10.15 mL/100 g/min in muscle, p=0.005) and the low blood flow fraction (less than 2 mL/100 g/min) was higher in the tumor $(0.5\%\;vs.\;5.2\%,\;p=0.005)$. The blood flow was not changed with the GBE in normal muscle, but was increased by $23.5\%$ ( p=0.0004) in the tumor. Conclusion : Based on these results, it can be concluded that the GBE enhanced the radiation effect significantly when used with fractionated radiotherapy as well as with single fraction irradiation. Furthermore, the GBE increased the blood flow of the tumor selectively.

Myocardial Perfusion after Transmyocardial Mechanical Revascularization in Rat Heart Transplant Model, Acute Model (백서 동종이식 심장모델에서 기계적 경심근 혈관재형성의 심근 혈류 개선 효과 : 급성기 모델)

  • Shinn Sung Ho;Chung Won Sand;Kang Jung Ho;Jeon Yang-Bin
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.468-475
    • /
    • 2005
  • Transmyocardial revascularization (TMR) in end stage ischemic heart disease results in variable clinical responses. We investigated the acute effect of early reperfusion and the angiogenesis after formation of the transmyocardial channel in a transplanted rat heart model with acute myocardial infarction. Material and Method: In the 30 transplanted hearts we induced acute myocardial infarction by ligating the proximal left coronary artery and inserted a porous 22G intravenous cannula into the left ventricle. After ten minutes of reperfusion, we removed the cannula. At every stage, we recorded the heart rate, QRS size, and left coronary arterial blood flow using the electrocardiogram and Doppler. One week later the rats were sacrificed and evaluated for the patency of intramyocardial channels and the angiogenesis. Result: The heart rates after ligation and after cannula insertion were $239.1\pm61.7,\;235.8\pm58.0bpm$ respectively, and they were statistically significantly slower than that of before ligation, $277.6\pm40.3bpm\;(p=0.017,\;p=0.007\;respectively)$. QRS sizes before ligation, after ligation, and after cannula insertion were $3.6\pm3.3mm,\;2.8\pm3.3 mm,\;and\;2.4\pm2.2mm,$respectively, and there was no significant difference in the three groups. Doppler findings after ligation showed that average peak and mean values of coronary perfusion were significantly decreased from $2.11\pm0.17kHz,\;1.25\pm0.22kHz\;to\;0.83\pm0.15kHz,\;0.38\pm0.11kHz$(p<0.05 respectively). After insertion of the porous cannula, the average peak and mean values of coronary perfusion were $0.61\pm0.05kHz\;and\;0.33\pm0.05 kHz$ respectively, but there was no statistically significant change compared to values after ligation. In all cases except one, pathologic findings showed no patent channels in the acute stage, however, one case showed the angiogenesis. Conclusion: We confirmed that TMR in a rat heart transplant model did not show blood flow through the channel in the acute stage. However, reperfusion effect in some cases had a potential for angiogenesis.

A Real Time 6 DoF Spatial Audio Rendering System based on MPEG-I AEP (MPEG-I AEP 기반 실시간 6 자유도 공간음향 렌더링 시스템)

  • Kyeongok Kang;Jae-hyoun Yoo;Daeyoung Jang;Yong Ju Lee;Taejin Lee
    • Journal of Broadcast Engineering
    • /
    • v.28 no.2
    • /
    • pp.213-229
    • /
    • 2023
  • In this paper, we introduce a spatial sound rendering system that provides 6DoF spatial sound in real time in response to the movement of a listener located in a virtual environment. This system was implemented using MPEG-I AEP as a development environment for the CfP response of MPEG-I Immersive Audio and consists of an encoder and a renderer including a decoder. The encoder serves to offline encode metadata such as the spatial audio parameters of the virtual space scene included in EIF and the directivity information of the sound source provided in the SOFA file and deliver them to the bitstream. The renderer receives the transmitted bitstream and performs 6DoF spatial sound rendering in real time according to the position of the listener. The main spatial sound processing technologies applied to the rendering system include sound source effect and obstacle effect, and other ones for the system processing include Doppler effect, sound field effect and etc. The results of self-subjective evaluation of the developed system are introduced.

Treatment of giant iatrogenic pseudoaneurysm of the femoral artery (대퇴동맥에 발생한 의인성 거대 가성동맥류에 대한 치료)

  • Kang, Wu-Seong;Park, Chan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.423-428
    • /
    • 2019
  • The role of angioembolization has increased because of increases in nonoperative treatment for traumatic splenic injury. We report here a case of successful treatment of iatrogenic pseudoaneurysm of the femoral artery by thrombin injection with coil embolization. A 55-year-old female was admitted to our hospital because of blunt trauma. Computed tomography (CT) revealed a grade V splenic injury with contrast extravasation; therefore, angioembolization was performed. Three days after admission, follow-up CT scan revealed rebleeding from the spleen, and repeat angioembolization was performed. Seven days after admission, an approximately $7.0cm{\times}4.0cm-sized$ pseudoaneurysm was found on follow-up CT scan and there was no bleeding from the spleen. Although thrombin was injected into the aneurysmal sac, there was still inflow of blood, as observed on color-doppler ultrasound. Therefore, coil embolization to the neck of the aneurysm was performed. On angiography, there was no contrast filling into the sac. The size of the pseudoaneurysmal sac had decreased on follow-up CT scan, and the patient was discharged to home without complications. We successfully treated a giant pseudoaneurysm of the femoral artery using thrombin and coil embolization.

A Study on Visible Light Communication with Turbo Coded OFDM for Intelligent Transport Systems (지능형 교통 시스템을 위한 Turbo Code OFDM 적용한 가시광 통신 시스템에 관한 연구)

  • Koo, Sung-Wan;Kim, Jin-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.2
    • /
    • pp.60-67
    • /
    • 2010
  • In the ubiquitous age, applications of wireless personal area network (WPAN) technology using LEDs are in progress. However, visible light communications (VLC) using the LEDs have weakness which deteriorate performance of communication because of multi-path fading that occurs propagation delay by interior walls or other things in indoor environments. In this paper, orthogonal frequency division multiplexing (OFDM) scheme is adapted to decrease multi-path fading and multi-path dispersion and to provide high speed data transmission. Besides, to reduce information losses caused by optical noise (incandescent lamps, fluorescent lamps, sunbeam etc.) also proposed channel coding using turbo codes. The encoding and decoding of the proposed system is described, and simulation results are analyzed. We can know that performance of proposed system is increased about 4 [dB] through the simulation results. Also, when the system take doppler effect, the system performance worsened.

A Study on Optimizing the Clutter Rejection Capability for a High-Speed Scanning MTI-Pulse Radar (고속 스캔 MTI 펄스 레이더의 지형 클러터 제거 능력 최적화에 관한 연구)

  • Kim, Jong-Geon;Jang, Heon-Soon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1077-1083
    • /
    • 2009
  • To reject the Doppler frequency spectrum dispersion of clutter caused by high-speed antenna rotation of MTI radar system due to terrain characteristics, signal processing parameters(MTI filter constant, M/N detector ration, K-factor and offset of CFAR) are adjusted for the optimal elimination of the ground clutter. For this investigation, logging equipment is designed and utilized for the collection of classified ground clutter data. Test case is devised through Matlab simulation for the classified analysis and optimization of clutter rejection. Then indoor radar test and outside test in accordance with terrain characteristics are repeatedly performed for the verification of the test. This whole process is through the evolutional development model and repeated for the optimization. Final result is that ground-clutter rejection capability is 5.6 times(7.5 dB) better than that of existing radar system.

A method of discharge estimation based on probabilistic velocity distribution function (확률론적 유속분포 공식을 활용한 유량 산정 방법)

  • Lee, Chan-Joo;Kim, Dong-Gu;Kwon, Seong-Il;Kim, Yong-Jeon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1781-1786
    • /
    • 2009
  • 최근 들어 하천의 자동유량측정에 많이 활용되고 있는 고정식 음파도플러유속계는 여러 개의 셀 유속 자료를 제공한다. 이러한 유속 자료들은 단면의 특정 위치에 고정되어 있어 수심 변화에 따라 변화하는 최대유속 구역을 직접 측정할 수 없으므로 최대유속과 평균유속 사이의 단순한 관계를 활용하여 유량 산정을 하기는 곤란하다. 다만, 단면상의 여러 지점에 대한 유속 측정치를 얻을 수 있다는 점을 이용하여 모의된 유속분포와 결부하면 유량을 산정하는데 활용 가능하다. 본 연구에서는 Chiu(1988)가 제안한 단면의 무차원적 유속분포를 모의하는 확률론적 유속분포 공식과 고정식 ADVM의 유속자료를 활용하여 유량을 산정하는 방법을 검토하였다. 유속분포 공식의 주요 매개변수 중에서 최대유속과 평균유속의 관계를 나타내는 �� 은 ADVM이 설치된 단면 및 인접 단면에서 ADCP로 측정한 자료를 이용하여 도출하였으며, $\beta$와 h는 국내 하천에 대한 자료 분석을 통해 얻어진 값을 사용하였다. 2006년부터 2007년까지의 유량이 비교적 안정된 11개 케이스의 댐 방류량 조건 및 동일한 지점에서 개발된 유속지수법 유량과 상호 비교하였으며, 그 결과 댐방류량 대비 상대오차가 평균 6.44%로 유속지수법의 7.43%에 비해 약간 크지만 유량 산정이 비교적 정확하게 이루어짐을 확인할 수 있었다. 또한 연속 유량 측정 결과 여수로 방류량에 대해서 약 10.6%의 오차를 나타내고 있었다. 한편, 보다 고유속 구역을 측정할 목적으로 2008년에 기존의 ADVM에 추가로 1.25m 높은 위치에 홍수 측정을 위한 저주파 ADVM을 설치하여 운영할 경우 2008년의 4개 케이스에 대해 댐방류량 대비 2.1%의 상대오차를 나타내어 3.9%의 유속지수법에 비해 약간의 개선효과가 있었으며, 이 역시 유량을 비교적 잘 산정하는 것으로 나타났다.

  • PDF

Efficient Acquisition of High-Quality ISAR Images Using the Discrete Gabor Representation in an Oversampling Scheme (Oversampling 형태를 갖는 Discrete Gabor Representation을 이용한 고품질 표적 ISAR 영상의 효율적인 획득)

  • Park, Ji-Hoon;Yang, Woo-Yong;Bae, Jun-Woo;Kang, Seong-Cheol;Myung, Noh-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.566-573
    • /
    • 2013
  • Inverse synthetic aperture radar(ISAR) images have been widely used in non-cooperative target recognition(NCTR). One of the most important issues in ISAR imaging is the improvement of the image smeared by target motion. In this paper, we propose the discrete Gabor representation(DGR) in an oversampling scheme for efficient acquisition of high-quality ISAR images. The DGR compartmentally assigns the Gabor coefficients to unit cells of the time-frequency grid related to the given Gabor logons. Thus, it can show an excellent time-frequency concentration and effectively discriminates the Doppler components from point-scatterers. The simulation results demonstrated that the DGR not only obtained high-quality ISAR images but also retained computational efficiency.

A Study on Analysis of Beat Spectra in a Radar System (레이다 시스템에서의 비트 스펙트럼 분석에 관한 연구)

  • Lee, Jong-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2187-2193
    • /
    • 2010
  • A specific radar system can be implemented more easily using the frequency modulated continuous wave comparing with the pulse Doppler radar. It also has the advantage of LPI (low probability of interception) because of the low power and wide bandwidth characteristics. These radars are usually used to cover the short range area and to obtain the high resolution measurements of the target range and velocity information. The transmitted waveform is used in the mixer to demodulate the received echo signal and the resulting beat signal can be obtained. This beat signal is analyzed using the FFT method for the purpose of clutter removal, detection of a target, extraction of velocity and range information, etc. However, for the case of short signal acquisition time, this FFT method can cause the serious leakage effect which disables the detection of weaker echo signals masked by strong side lobes of the clutter. Therefore, in this paper, the weighting window method is analyzed to suppress the strong side lobes while maintaining the proper main lobe width. Also, the results of FFT beat spectrum analysis are shown under various environments.