• Title/Summary/Keyword: 데이터 전송 시스템

Search Result 4,243, Processing Time 0.034 seconds

Computer-guided implant surgery and immediate provisionalization by chair-side CAD-CAM: A case report (진료실 CAD-CAM에 의한 컴퓨터 가이드 임플란트 수술과 즉시 임시보철치료: 증례보고)

  • Hyun, Sang Woo;Lee, sungbok Richard;Lee, Suk Won;Cho, Young Eun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.478-486
    • /
    • 2021
  • This report demonstrates a method of generating a chair-side and computer-aided template for implant surgery based on the Top-Down and restoration-driven concept. Compared to the traditional CAD-CAM process which requires multiple steps to be taken between dental clinic and laboratory, this alternative procedure, VARO guide system (VARO Guide, CAD, Pre-Guide, VARO-mill, NeoBiotech, Seoul, South Korea) enables accurate and patient-friendly implant surgery as well as immediate provisional restoration in a single visit. First, bite-registration at centric jaw relation and CBCT were taken using the Pre-Guide. The CBCT data was then reorganized directly through the chair-side CAD, and we could determine the most appropriate 3-dimensional position of implant. The STL file was extracted and put into the chair-side CAM (VARO-mill) to fabricate a VARO. This surgical guide allowed the implants to be accurately positioned into the planned sites within an hour.

IPC Code Based Analysis of Technology Convergence of the IoT Patents in South Korea, China, and Japan : Focusing on PCT International Applications (한중일 사물인터넷(IoT) 관련 특허의 IPC 코드 기반 기술융복합 분석 : PCT 국제출원을 중심으로)

  • Shim, Jaeruen
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.7
    • /
    • pp.949-955
    • /
    • 2020
  • In this Study, Social Network Analysis of IoT related patents in South Korea, China, and Japan was conducted from the viewpoint of patent informatics. To this end, 2,526 patents filed by PCT until December 2019 were investigated up to the subclass level of the IPC code. As a result, in the case of South Korea, representative IPC codes are in the order of G06Q, H04L, G06F, H04W, and the highest frequency of interconnection is H04L→H04W, H04W→H04L, H04W→H04B. In China, the representative IPC codes are in the order of H04L, H04W, G05B, G06Q. South Korea has strong technological convergence centered on the G06Q, while China has strong convergence centered around H04L and H04W. Moreover, in China, H04L and H04W have more diverse combinations than in South Korea in Section A, B, G, and H. In the future, it is necessary to study the diversity of technology convergence of H04L and H04W in China.

The Impact of Blockchain Technology on Banks' Conventional Trade Settlements (블록체인기술이 무역결제방식에 미치는 영향에 관한 연구)

  • Zhao, Xiao;Hwang, Ki-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.3
    • /
    • pp.346-354
    • /
    • 2021
  • Since 2015, Blockchain has experienced rapid development throughout the world, institutions including Central Banks, Government Departments, Commercial Banks, IT Giants are all accelerating their exploration on Blockchain, and investment on Blockchain related R&D departments and start-up companies also shows explosive growth. This paper studies the impact of blockchain technology on banks' conventional trade settlement methods and describes blockchain technology in term of its concepts, advantages, and disadvantages. It also studies the application processes of blockchain technology combined with conventional trade settlement methods (remittance, collection, and L/C), and analyzes the positive and negative impacts of blockchain technology on the conventional trade settlement methods. In addition, this paper lists the blockchain application cases, analyzes the technology development status and existing problems, and puts forward suggestions and measures for the development of blockchain finance in China based on the case analysis and impact research.

Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module (고감도 보급형 방사선 측정센서 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.510-514
    • /
    • 2022
  • In this paper, we propose the development of high-sensitivity low-end radiation measuring sensor module. The proposed measurement sensor module is a scintillator + photomultiplier(SiPM) sensor optimization structure design, amplification and filter and control circuit design for sensor driver, control circuit design including short-distance communication, sensor mechanism design and manufacturing, and GUI development applied to prototypes consists of, etc. The scintillator + photomultiplier(SiPM) sensor optimization structure design is designed by checking the characteristics of the scintillator and the photomultiplier (SiPM) for the sensor structure design. Amplification, filter and control circuit design for sensor driver is designed to process fine scintillation signal generated by radiation with a scintillator using SiPM. Control circuit design including short-distance communication is designed to enable data transmission through MCU design to support short-range wireless communication function and wired communication support. The sensor mechanism design and manufacture is designed so that the glare generated by wrapping a reflective paper (mirroring) on the outside of the plastic scintillator is reflected to increase the efficiency in order to transmit the fine scintillation signal generated from the plastic scintillator to the photomultiplier(SiPM). The GUI development applied to the prototype expresses the date and time at the top according to each screen and allows the measurement unit and time, seconds, alarm level, communication status, battery capacity, etc. to be expressed. In order to evaluate the performance of the proposed system, the results of experiments conducted by an authorized testing institute showed that the radiation dose measurement range was 30 𝜇Sv/h ~ 10 mSv/h, so the results are the same as the highest level among products sold commercially at domestic and foreign. In addition, it was confirmed that the measurement uncertainty of ±7.4% was measured, and normal operation was performed under the international standard ±15%.

Dynamic Channel Management Scheme for Device-to-device Communication in Next Generation Downlink Cellular Networks (차세대 하향링크 셀룰러 네트워크에서 단말 간 직접 통신을 위한 유동적 채널관리 방법)

  • Se-Jin Kim
    • Journal of Internet Computing and Services
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2023
  • Recently, the technology of device-to-device(D2D) communication has been receiving big attention to improve the system performance since the amount of high quality/large capacity data traffic from smart phones and various devices of Internet of Things increase rapidly in 5G/6G based next generation cellular networks. However, even though the system performance of macro cells increase by reusing the frequency, the performance of macro user equipments(MUEs) decrease because of the strong interference from D2D user equipments(DUEs). Therefore, this paper proposes a dynamic channel management(DCM) scheme for DUEs to guarantee the performance of MUEs as the number of DUEs increases in next generation downlink cellular networks. In the proposed D2D DCM scheme, macro base stations dynamically assign subchannels to DUEs based on the interference information and signal to interference and noise ratio(SINR) of MUEs. Simulation results show that the proposed D2D DCM scheme outperforms other schemes in terms of the mean MUE capacity as the threshold of the SINR of MUEs incareases.

LAN Based MFD Interface for Integrated Operation of Radio Facilities using Fishery Vessel (어선용 무선설비의 통합운용을 위한 LAN 기반 MFD 인터페이스)

  • In-ung Ju;In-suk Kang;Jeong-yeon Kim;Seong-Real Lee;Jo-cheon Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.496-503
    • /
    • 2022
  • In the reality that the fishing population is decreasing and the single-man fishing vessels is increasing, mandatory equipment for navigation and radio equipments for the safety of fishing boats has continued to be added. Therefore, many equipment such as navigation, communication and fishing are installed in the narrow steering room, so it is very confusing and a number of monitors are placed in the front, which is a factor that degrades the function of maritime observation. To solve this problem, we studied an interface that integrates and operates to major radio facilities such as very high frequency-digital selective calling equipment (VHF-DSC), automatic identification system (AIS) and fishing boat location transmission device (V-pass) into one multi function display (MFD) based on LAN. In addition, IEC61162-450 UDP packets and IEC61162 sentence were applied to exchange data through link between MFD and radio equipments, and additional messages needed for each equipment and function were defined. The integrated MFD monitor is easily operated by the menu method, and the performance of the interface was evaluated by checking the distress and emergency communication functions related to maritime safety and the message transmission status by equipment.

A Study on Termite Monitoring Method Using Magnetic Sensors and IoT(Internet of Things) (자력센서와 IoT(사물인터넷)를 활용한 흰개미 모니터링 방법 연구)

  • Go, Hyeongsun;Choe, Byunghak
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.206-219
    • /
    • 2021
  • The warming of the climate is increasing the damage caused by termites to wooden buildings, cultural properties and houses. A group removal system can be installed around the building to detect and remove termite damage; however, if the site is not visited regularly, every one to two months, you cannot observe whether termites have spread within, and it is difficult to take prompt effective action. In addition, since the system is installed and operated in an exposed state for a long period of time, it may be ineffective or damaged, resulting in a loss of function. Furthermore if the system is installed near a cultural site, it may affect the aesthetic environment of the site. In this study, we created a detection system that uses wood, cellulose, magnets, and magnetic sensors to determine whether termites have entered the area. The data was then transferred to a low power LoRa Network which displayed the results without the necessity of visiting the site. The wood was made in the shape of a pile, and holes were made from the top to the bottom to make it easier for termites to enter and produce a cellulose sample. The cellulose sample was made in a cylindrical shape with a magnet wrapped in cellulose and inserted into the top of a hole in the wood. Then, the upper part of the wood pile was covered with a stopper to prevent foreign matter from entering. It also served to block external factors such as light and rainfall, and to create an environment where termites could add cellulose samples. When the cellulose was added by the termites, a space was created around the magnet, causing the magnet to either fall or tilt. The magnetic sensor inside the stopper was fixed on the top of the cellulose sample and measured the change in the distance between the magnet and the sensor according to the movement of the magnet. In outdoor experiments, 11 cellulose samples were inserted into the wood detection system and the termite inflow was confirmed through the movement of the magnet without visiting the site within 5 to 17 days. When making further improvements to the function and operation of the system it in the future, it is possible to confirm that termites have invaded without visiting the site. Then it is also possible to reduce damage and fruiting due to product exposure, and which would improve the condition and appearance of cultural properties.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Improvement Way for Mobile X-ray Examinations by Rule Revision about Safety Management of Diagnosis Radiation Occurrence System (진단용방사선발생장치의 안전관리에 관한 규칙 개정에 따른 이동형 방사선검사의 개선방안)

  • Choi, Jun-Gu;Kim, Gyeong-Su;Kim, Byeong-Gi;Ahn, Nam-Jun;Kim, Hyeong-Sun;Kim, Sang-Geon;Lim, Si-Eun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A safety management rule of the diagnosis radiation system which opened a court 2006 February 10th was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this study is to minimize injury by radiation that can happen to patients and people around a sick ward when managing mobile X-ray system. This study analyzed sickroom environment of mobile X-ray examination and the statistical data of the Konkuk medical Information System(KIS) and the Picture Archiving Communication System(PACS). This study also investigated patient conditions, infection, relation information and related data, when the sickroom mobile X-ray examination is used. Through data analysis, many problems were expected such as restriction of space side, manpower and expense of business side, satisfaction degree decline of patient and protector of operation side. Therefore, we tried to restrict examination of multi bed sickroom, and to use treatment room in each ward to solve problem mentioned. As a result, the whole sickroom mobile X-ray examination rate decreased to near 50%, and mobile X-ray examination rate for inpatients decreased to more than 85%. This study shows that several attempts we did should be helpful for manpower, patients satisfaction and expenses. Also, they should protect patients in sickroom from unnecessary radiation exposure and could minimize inconvenience of patients and their family members from x-ray examination.

  • PDF

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.