• Title/Summary/Keyword: 데이터 논문

Search Result 41,256, Processing Time 0.064 seconds

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

Preliminary Diagnosis of Fishing Ground Environment for Establishing the Management System in Fisheries Resources Protection Area (수산자원보호구역 관리체제 구축을 위한 어장환경 예비진단)

  • Lee, Dae-In;Park, Dal-Soo;Jeon, Kyeong-Am;Eom, Ki-Hyuk;Park, Jong-Soo;Kim, Gui-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.79-89
    • /
    • 2009
  • For preliminary diagnosis on current fishing ground environment and basic information for establishment of effective and rational management policy in fisheries resources protection area, water and sediment quality and changes of total area in the 10 marine protection areas designated for fisheries resources management in Korea were assessed. Results showed that environmental quality in these areas has been degraded by pollution sources, coastal utilization and development stress, etc. The pattern and degree of contamination differed by protection areas, suggesting that it is necessary for optimum environmental management plan considering the regional characteristics. The total designated area of protection areas in 2003 changed by $-22.9{\sim}2.4%$, on average -6.4%, compared with the first year of designation; Wando-Doam Bay showd the highest increase rate (2.4%), and Hansan Bay has the highest decrease rate (-22.9%) Decrease rate of land and sea in total area showd 6.1% and 6.6%. An integrated management of environmental data in protection areas is required for systematic assessment. Therefore, the suitable environmental and information management is needed specifically considering the environment characteristics such as development and utilization conditions of land and sea area Furthermore, bemuse urbanization and industrialization threats the junctions of the protection areas, authorized ministry (MIFAFF) should develope and establish monitoring and management procedures based on the related laws.

  • PDF

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

Radiographic Status of the Visited Patients at University Hospital Emergency Room (한 대학병원 응급실 내원환자의 방사선촬영 실태)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distriution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 1270 emergency outpatients who visit during JAN, 2009at ER of the general hospital in Gwang city. The results is as follows : Emergency radiography rate of simple radiography was 56.6%, special radiography 2. 5%, CT 34.2%, and ultrasonography 6.7%, In simple radiography rate. a high rate was distributed on male(63.6%), thoracicsurgery part(90.0%), admission patient(77.9%), and long stayed patient at ER. In special raiography rate, a high rate was obsurved in urologic part(28.6%), and in CT rate, observed neurosurgerty part(49.2%) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8%) and internal medicine part(15.9%). There are distributed regional radiography rate in radio-graphic type that chest(55.3%) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0%) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neuro surgery, chest(90.0%) in thoracic surgery, abdomen(58.0%) in general surgery, spine(40.0%) in neuro surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiopraphic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transferred patient(2.7) in patient type, and on nurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional party was highly distributed on chest(998 case number.) Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography. Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always sitted with CT room and monitoring patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiopraphy should be established in ER area, and the radioprapher of this room should be stationed radiologic technician who is career and can implement emergency patient care and The disposition of men which is appropriate with emergency patient increase is necessary.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Effect of Patient Size on Image Quality and Dose Reduction after Added Filtration in Digital Chest Tomosynthesis (부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과)

  • Bok, Geun-Seong;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • To evaluate the effect of patient size on effective dose and image quality for Digital Chest Tomosynthesis(DTS) using additional 0.3 mm copper filtration. Eighty artificial nodules were placed in the thorax phantom("Lungman," Kyoto Kagaku, Japan), and Digital Chest Tomosynthesis(DTS) images of the phantom were acquired both with and without added 0.3 mm Cu filtration. To simulate patients of three sizes: small, average size and oversize, one or two 20-mm-thick layer of PMMA(polymethyl methacrylatek) blocks were placed on the phantom. The Effective dose was calculated using Monte Carlo simulations. Two evaluations of image quality methods have been employed. Three readers counted the number of nodules detected in the lung, and the measured contrast-to-noise ratios(CNRs) were used. Data were analyzed statistically. The ED reduced $26{\mu}Sv$ in a phantom, $33{\mu}Sv$ in one 20-mm-thick layer of PMMA block placed on the phantom, and $48{\mu}Sv$ in two 20-mm-thick layer of PMMA blocks placed on the phantom. The Effective dose(ED) differences between DTS with and without filtration were significant(p<0.05). In particular, when we used two 20-mm-thick layer of PMMA blocks placed on the phantom, the ED was significantly reduced by 36% compared with those without additional filtration. Nodule detection sensitivities were not different between with and without added filtration. Differences of CNRs were statistically insignificant(p>0.05). Use of additional filtration allows a considerable dose reduction during Digital Chest Tomosynthesis(DTS) without loss of image quality. In particular, additional filtration showed outstanding result for effective dose reduction on two 20-mm-thick layer of PMMA blocks placed on the phantom. It applies to overweight patients.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Comparative Study on the Estimation of CO2 absorption Equilibrium in Methanol using PC-SAFT equation of state and Two-model approach. (메탄올의 이산화탄소 흡수평형 추산에 대한 PC-SAFT모델식과 Two-model approach 모델식의 비교연구)

  • Noh, Jaehyun;Park, Hoey Kyung;Kim, Dongsun;Cho, Jungho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.136-152
    • /
    • 2017
  • The thermodynamic models, PC-SAFT (Perturbed-Chain Statistical Associated Fluid Theory) state equation and the Two-model approach liquid activity coefficient model NRTL (Non Random Two Liquid) + Henry + Peng-Robinson, for modeling the Rectisol process using methanol aqueous solution as the $CO_2$ removal solvent were compared. In addition, to determine the new binary interaction parameters of the PC-SAFT state equations and the Henry's constant of the two-model approach, absorption equilibrium experiments between carbon dioxide and methanol at 273.25K and 262.35K were carried out and regression analysis was performed. The accuracy of the newly determined parameters was verified through the regression results of the experimental data. These model equations and validated parameters were used to model the carbon dioxide removal process. In the case of using the two-model approach, the methanol solvent flow rate required to remove 99.00% of $CO_2$ was estimated to be approximately 43.72% higher, the cooling water consumption in the distillation tower was 39.22% higher, and the steam consumption was 43.09% higher than that using PC-SAFT EOS. In conclusion, the Rectisol process operating under high pressure was designed to be larger than that using the PC-SAFT state equation when modeled using the liquid activity coefficient model equation with Henry's relation. For this reason, if the quantity of low-solubility gas components dissolved in a liquid at a constant temperature is proportional to the partial pressure of the gas phase, the carbon dioxide with high solubility in methanol does not predict the absorption characteristics between methanol and carbon dioxide.

Norm-referenced criteria for strength of the elbow joint for the korean high school baseball players using the isokinetic equipment: (Focusing on seoul and gyeonggi-do) (등속성 장비를 이용하여 한국고교야구선수 주관절 근력 평가기준치 설정: (서울 및 경기도 중심으로))

  • Kim, Su-Hyun;Lee, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.442-447
    • /
    • 2017
  • The purpose of this study was to establish norm-referenced criteria for the isokinetic strength of the elbow joint in Korean high school baseball players. Two hundred and one high school baseball players participated in this study, none of whom had any medical problem with their upper limbs. The elbow flexion/extension test was conducted four times at a speed of $60^{\circ}/sec$. The HUMAC NORM (CSMI, USA) system was used to obtain the values of the peak torque and peak torque per body weight. The results were presented as norm-referenced criterion valuesusing the 5-point scale of Cajori which consists of five stages (6.06%, 24.17%, 38.30%, 24.17%, and 6.06%). In the results of this study, the peak torques of the elbow (flexor and extensor?) at an angular velocity of $60^{\circ}/sec$ were $37.88{\pm}8.14Nm$ and $44.59{\pm}11.79Nm$, and the peak torque per body weight of the elbow (flexor and extensor?) were $50.06{\pm}8.66Nm$ and $58.28{\pm}12.84Nm$, respectively. The reference values of the peak torque and peak torque per body weight of the elbow flexor and extensor were setat an angular velocity of $60^{\circ}/sec$. On the basis of the results analyzed in this study, the following conclusions were drawn. There is a lack of proper studies on the elbow joint strength, even though the most common injury in baseball players occurs in the elbow joint. Therefore, we need to establish a standard muscle strength in order to prevent elbow joint injuries and improve their performance. The criteria for the peak torque and peak torque per body weight established here in will provide useful information for high school baseball players, baseball coaches, athletic trainers and sports injury rehabilitation specialists in injury recovery and return to rehabilitation, which can beutilized as objective clinical assessment data.