• Title/Summary/Keyword: 데이터 감소

Search Result 4,320, Processing Time 0.032 seconds

Research on Changing of Renal Relative Uptake Depending on the Setting of Background ROI in Kidney MAG3 Study of Hydronephrosis Patients (Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구)

  • Noh, Ik Sang;Ahn, Byung Ho;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • Purpose: To evaluate kidney function, renal relative uptake is very important and is affected by kidney and the setting of background region of interest (ROI). In particular, in the case of patients with hydronephrosis to the naked eyes, such as size, position and shape etc. can be difficult to identify. So according to ROI to be set by user, the results are many differences. This study assumes the ROI of a constant kidney. According to the change of background ROI by analyzing renal relative uptake affect how the results are intended to study. Materials and Methods: From January 2012 to February 2013, we analyzed 27 patients with hydronephrosis who were examined MAG3 test in nuclear medicine department of Samsung medical center. After patients were received intravenous injection of $^{99m}Tc-MAG3$ 185 MBq (5 mCi) data were obtained. While we reconstructed images of patients, we've changed background ROI in the process of setting up ROI. First, in the process of renal processing, automatic ROI which set automatically and background ROI which needed to set manually were compared. Second, we set the ROI position separated by above, lateral and bottom of kidney. Third, background setting time were compared with 1-2 min and 2-3 min. Results: The relative uptake occurred in 3.7%p of the errors on average in Automatic & Manual ROI study. And comparison of background ROI position study, located in the lower position was more accurate results. Above, lateral, bottom each of the values 74.6%, 67.6% and 62.0% showed respectively. The standard value was 59.9%. finally, split function range test doesn't show significant difference. Conclusion: The study shows that relative uptake of kidney is affected in the background ROI. Therefore, it should be set by considering various dependent factors.

  • PDF

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Occurrence Pattern of Intussusception according to the Introduction of Rotavirus Vaccine: An Observational Study at a University Hospital (로타바이러스 백신 도입에 따른 장겹침증 발생 경향: 한 대학병원 관찰 연구)

  • Nam, Hye Na;Lim, Kyung In;Tchah, Hann;Ryoo, Eell;Sun, Yong Han;Cho, Hye-Kyung
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.3
    • /
    • pp.202-208
    • /
    • 2016
  • Purpose: Rotavirus vaccine (RV) was introduced in Korea since 2007, and intussusception (IS) remains an important safety concern. This study investigated the trend of IS occurrence related to RV as well as the temporal relevance between vaccination and IS in children. Methods: We collected data of the patient aged ${\leq}18$ years with IS admitted to Gachon University Gil Medical Center, 2003 to 2015. For the patients that have occurred since 2008, the immunization records of RV were collected. The proportion of cases <1 year was calculated by the year and the temporal relationship between vaccination and IS occurrence was analyzed. Results: A total of 696 IS cases were noted. The cases <1 year were 30.7% (214/696). Although the incidence of all IS has increased over the 13-year period (from 74.1 in 2003 to 89.5 in 2015, linear by linear association, P=0.003), the incidence of IS <1 year has not increased (from 56.9 in 2003 to 53.3 in 2015, P=0.910), and the proportion of cases <1 year has decreased (from 35.4 in 2003 to 18.8 in 2015, P=0.000). Of 128 cases <1 year since 2008, 53.9% received RV. In the vaccinated group, 10 cases of IS occurred within 30 days, and eight cases did within 31 to 60 days. Numbers of IS after first, second, and third dose were three, 10, and five cases, respectively. Conclusions: Occurrence of IS in children <1 year of age did not increase since the introduction of RV. Further monitoring is essential for evaluation of vaccine safety.

Analysis of Systems Thinking Level of Pre-service Teachers about Carbon Cycle in Earth Systems using Rubrics of Evaluating Systems Thinking (시스템 사고 평가 루브릭을 활용한 예비교사들의 지구 시스템 내 탄소 순환에 대한 시스템 사고 수준 분석)

  • Park, Kyungsuk;Lee, Hyundong;Lee, Hyonyong;Jeon, Jaedon
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.5
    • /
    • pp.599-611
    • /
    • 2019
  • The purpose of this study is to analyze the systems thinking level of pre-service teachers using rubrics of evaluating systems thinking. For this purpose, systems thinking level model, which can be applied to education or science education, was selected through literature analysis. Eight pre-service teachers' systems thinking were investigated through the systems thinking analysis tool used in domestic research. The systems thinking presented by the pre-service teachers were transformed into the box type causal map using Sibley et al. (2007). Two researchers analyzed the systems thinking using rubrics of evaluating systems thinking. For data analysis, quantitative analysis was performed through correlation analysis using SPSS. In addition, the qualitative analysis of the box type causal map was conducted and the consistency with the quantitative analysis results was verified. The results indicated that the correlation between the 5-Likert systems thinking measurement instrument and the rubrics score was highly correlated with the Pearson product-moment of .762 (p <.05). In the hierarchical correlation of the systems thinking level, the STH model was analyzed with a very high correlation with the Pearson product-moment of .722~.791, and 4-step model was analyzed .381~.730. The qualitative analysis suggested the concept to be included in the low level of system thinking, the higher the level, the less the concept that is presented properly. In conclusion, the level of systems thinking can be derived as a result of research that there is clearly, a hierarchical part. Based on the results of this study, it is necessary to develop a systems thinking level model applicable to science education and develop and validate items that can measure the level of systems thinking.

Investigation of Measurement Feasibility of Particulate Matter Concentration by Different Land-Use Types Using Drone (드론을 이용한 토지이용별 미세먼지 농도 측정 가능성 모색 연구)

  • Son, Seung-Woo;Yu, Jae-Jin;Kim, Dong-Woo;Kim, Tae-Hyun;Sung, Woong-Gi;Yoon, Jeong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.259-267
    • /
    • 2020
  • This study measured the Particulate Matter (PM) concentration according to altitude (30 m, 60 m, 90 m, 120 m, and 150 m) in three different environments: a construction site, natural environment (arboretum), and residential area. PM2.5 and PM10 values at 30 m above the construction site were 18.63 ㎍/㎥ and 24.23 ㎍/㎥ while values at 150 m were 10.89 ㎍/㎥ and 10.61 ㎍/㎥, respectively, indicating the average concentration decreased as altitude increased. PM2.5 and PM10 values at 30 m above the natural environment were 9.03 ㎍/㎥ and 11.21 ㎍/㎥ while those at 150 m were 3.42 ㎍/㎥ and 3.57 ㎍/㎥, respectively, showing lower average concentrations as altitude increased. PM2.5 and PM10 values at 30 m above the residential area were 10.65 ㎍/㎥ and 12.06 ㎍/㎥ while those at 150 m were 4.24 ㎍/㎥ and 5.17 ㎍/㎥, also demonstrating lower PM concentrations as altitude increased. The PM concentrations decreased as altitude increased at all tested sites and also decreased between environments in the following order: construction site, residential area, and natural environment. The results of this study are significant because PM concentrations were measured at various altitudes at different land-use sites. The results are expected to serve as basic data for decision-making in both regional and urban planning.

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Development of a New Terrain Type Classification to be used in Highway Design (도로설계 적정화를 위한 새로운 지형구분에 관한 연구)

  • Kim, Sang-Youp;Choi, Jai-Sung;Lee, Seung-Yong;Han, Hyung-Gwan
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.49-62
    • /
    • 2006
  • The republic of korea has put a great emphasis on the role of the road as widening a social infra-structural facility. Thus, vast amount of money has been invested on the road establishment. As a result, there has been fruitful outcomes in establishing the road system of the nation especially for the flat road with ease. However, in order to have more systematic and sustainable road system, we should turn our attention to more painful and high-cost regions such as mountainous districts and those are to be developed effectively. The configuration of the road is an important factor to be considered in making a decision for the road planning. Nevertheless, current road planning criterion has no such clarified and objective judging standard for figuring the configuration of the road out and, as a result, speed planning can be decided incorrectly. our research has acknowledged the necessity of estimating the configuration of the road and aimed to make it organized and sorted according to the height, slope, and the vehicle's speed. The results are as follows. First, our research made use of GIS data and classified the road into 9 different areas according to the height and the slope. Also, road classification being matched to the data of vehicle's speed, it has been shown that those characteristics of different areas have made an influence on vehicle's speed. Secondly, based on the results of the similarity between geographical classification and, vehicle's speed of sorted groups according to the height and the slope, conclusively we have classified as flat, rolling region and mountain. Since our research has made use of vehicle's speed for National Highway, it is not applicable to different functional highways. However, for the highway to be established hereafter, it can be a standard for reflection geographical characteristics.

  • PDF

Quantitative Measurement of Carbon Dioxide Consumption of a Whole Paprika Plant (Capsicum annumm L.) Using a Large Sealed Chamber (대형 밀폐 챔버를 이용한 파프리카(Capsicum annumm L.) 개체의 이산화탄소 소비량 측정 및 정량화)

  • Shin, Jong-Hwa;Ahn, Tae-In;Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.29 no.3
    • /
    • pp.211-216
    • /
    • 2011
  • This study was carried out to clarify precise $CO_2$ demands of paprika plants (Capsicum annumm L.) by measuring photosynthesis rates of the leaves in high, low positions, and the $CO_2$ consumption of a whole plant in a large sealed chamber. A photosynthesis measuring system (LI-6400) was used to measure the photosynthetic rates of the leaves located in different positions. A large sealed chamber that can control inside environmental factors was developed for measuring $CO_2$ consumption by a whole paprika plant. With increase of radiation, photosynthetic rates of the leaves in higher position became larger than those in lower position. The $CO_2$ consumption by the plant was estimated by using decrement of $CO_2$ concentration from initial level of 1500 ${\mu}mol{\cdot}mol^{-1}$ in the chamber with increase of integrated radiation. A regression model for estimating $CO_2$ consumption by the plant (leaf area = 7,533.4 $cm^2$) was expressed with integrated radiation (x) and was suggested as $y=-0.06234+3.671^*x/(2.589+x)$ ($R^2=0.9966^{***}$). The photosynthetic rate of the whole plant measured in the chamber was 3.4 ${\mu}mol\;CO_2{\cdot}m^{-2}{\cdot}s^{-1}$ under 300 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ light intensity, which is in-between photosynthetic rates of the leaves in high and low positions. For this reason, some differences between required and supplied $CO_2$ amounts in greenhouses might occur when depending too much on photosynthetic rates of leaves. Therefore, we can estimate more accurately $CO_2$ amount required in commercial greenhouses by using $CO_2$ consumption model of a whole plant obtained in this study in addition to leaf photosynthetic rate.

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.