• Title/Summary/Keyword: 대형 기둥

Search Result 65, Processing Time 0.064 seconds

Seismic Performance of RC Column-Steel Beam Connections for Large Columns (대형기둥 적용을 위한 철근콘크리트기둥-강재보 접합부의 내진성능)

  • Park, Hong Gun;Lee, Ho Jun;Kim, Chang Soo;Hwang, Hyeon Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.231-242
    • /
    • 2016
  • Earthquake resistance of RC column-steel beam (RCS) joints with simplified details were studied. Simplified details are necessary for large columns to improve the productivity and constructability. To strengthen the beam-column joint, the effects of transverse beams, studs, and U-cross ties were used. Four 2/3 scale interior RCS connections were tested under cyclic lateral loading. The specimens generally exhibited good deformation capacity exceeding 4.0% story drift ratio after yielding of both beam and beam-column joint. Ultimately, the specimens failed by shear mechanism of the joint panel. The test strengths were compared with the predictions of existing design methods.

Cyclic Lateral Loading Test for Cast-In-Place Concrete-Filled Hollow PC Columns Using Permanent Inner form (영구 내부거푸집을 이용한 현장타설 콘크리트 채움중공 PC기둥의 반복횡가력실험)

  • Lee, Ho-Jun;Park, Hong-Gun;Kim, Chang-Soo;Hwang, Hyeon-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.129-139
    • /
    • 2016
  • Cast-in-place concrete-filled hollow PC (HPC) columns are used to reduce lifting load of heavy-weight PC columns and to improve the structural integrity of joints. In the present study, a new type of HPC column was proposed to improve the productivity and structural integrity of the concrete. To form the hollow PC columns, a permanent inner form was prefabricated using structural deck plates and penetrated lateral bars. Half-scale specimens of four HPC columns were tested under combined axial compression and lateral cyclic loading to evaluate the seismic resistance. In the design of test specimens, various parameters such as the spacing of lateral re-bars, the use of steel fiber, and the thickness of PC cover were considered. The test results showed that the proposed HPC columns generally exhibited satisfactory load-carrying capacity and deformation capacity without brittle failure of PC. If closely spaced hoops or fiber reinforcements are used for PC, the deformation capacity can be improved further by restraining PC spalling.

Performance Evaluation of Junctions between Multi-Tubular and Cylindrical Sections for Steel Wind Tower (멀티기둥-강관 풍력타워 연결부 성능 평가)

  • Kim, Jongmin;Park, Hyun-Yong;Kim, Kyungsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1764-1769
    • /
    • 2014
  • Numerical investigations have been conducted on the junction that connect the multi-tubular section and the single shell section in order to evaluate applicability of hybrid sections in wind turbine towers instead of conventional single shell towers. Major characteristics in structural details include extension of multi-tubular member into shell end section, installation of wing stiffeners, and different layout of floor beams. Elastic and nonlinear incremental analyses were conducted to examine stress concentration patterns and ultimate behaviors, respectively. Based on evaluation of structural performance due to vertical and horizontal forces, it has been confirmed that installation of floor beams and wing stiffeners sensitively affect ultimate strength of global wind tower.

Finite Element Analyses on Local Buckling Strength of Polygonal-Section Shell Towers (축방향 압축을 받는 다각형 단면 쉘 기둥구조의 국부좌굴강도에 관한 해석적 연구)

  • Park, Seong-Mi;Choi, Byung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1900-1907
    • /
    • 2012
  • Since the subpanels of polygonal-section shell have the corners of an obtuse angle larger than 90 degree unlike general plate or box-section structures, this could have an influence on forming nodal lines against local plate buckling or stress distributions. However, there is not sufficient material in the relevant study results or design recommendations. The very feasible models of the initial imperfections were acquired through the literature studies and then the parametric studies were conducted along with the initial imperfection models by using the finite element method. The parameters like the size of residual stresses, the portion of compressive residual stresses, and steel grades were considered. From the parametric studies, it was found that the maximum residual stress is more influential factor than the distribution pattern of residual stresses. In addition, The design strength equations for the simply supported plates can be applicable to the determination of the local buckling strength of the polygonal cross-section shell structures.

Behavior of CFT Column to H-Beam Full-Scale Connections with External T-Stiffeners (T-스티프너 보강 CFT 기둥 - H형강보 실대형 접합부의 거동)

  • Kim, Young Ju;Kang, Chang Hoon;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.715-723
    • /
    • 2001
  • This paper represents the behavior of CFT column to H-beam full-scale connection with external T-stiffener. 6 specimens whose T-stiffeners which are compounded of vertical element and horizontal element were made under the parameter of the strength ratio of each elements(vertical element and horizontal element in T-stiffener) to the beam full plastic moment. The analysis-parameters demonstrated in the base of the data that we get in experiment are strength stiffness, and plastic rotational capacity. All of specimen showed stable hysteretic behavior, and the horizontal element is more critical than vertical element in strength and stiffness. The mean beam plastic rotation of all specimen except the TS-2 specimen is 2.97% rad.

  • PDF

Finite element analysis on local buckling strength of hexagon columns with press-braked sections (절곡 제작한 6각형 단면 기둥 국부좌굴강도의 해석적 평가)

  • Park, Seong-Mi;Choi, Byung-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.461-464
    • /
    • 2011
  • 대형 다각형 단면 기둥부재의 제작은 용접이나 절곡 등의 다양한 혼합방식으로 이루어 질 수 있다. 이러한 제작방식의 차이에 따라 외력작용 이전의 초기상태에 상당한 차이가 발생한다. 그러나 절곡과 용접이 혼합된 다각형 단면 기둥의 초기 상태를 고려하는 방안에 대한 지침은 분명히 제시되고 있지 않다. 이에 본 연구에서는 다각형 단면 기둥 제작방식에 따른 초기상태가 국부좌굴강도에 미치는 영향을 6각형 단면 기둥모델을 대상으로 해석적으로 평가해 보고자 한다.

  • PDF

Inelastic Analysis of Steel-Concrete Composite Column with Non-Compact Steel Section (비조밀단면을 가진 SC 합성 기둥의 비선형 해석)

  • Oh, Myoung Ho;Jang, Tae Young;Kim, Myeong Han;Kim, Dae Joong;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.63-71
    • /
    • 2005
  • There were already several studies conducted on the steel-concrete (SC) composite column, which was developedcomplement the weaknesses and maintain the advantages of previous composite columns. The axial compressive capacity of the SC composite column was estimated by the tests in previous studies, but the experiments for the large-scale column could not be performed because of the limitation with the laboratory's capacity. In this study, the analytical study was performed using the general finite element analysis program to reflect the interaction of concrete and steel and the local buckling of steel flange composed of the non-compact section. The appropriateness of the analytical model was verified by the comparison between experimental and analytical results. The nonlinear behavior of full-scale SC composite column was analyzed using the verified analytical model. From these analytical studies, it was concluded that the width-to-thickness ratio of the steel cross-section of the SC composite column should not exceed 25:0. The section area of the link is best when it is over 0.025 dt, and the link distance is to be less than D/2 or 300mm.

A study on improved analytic method for the bond stress between concrete and steel tube in CFT column (CFT기둥에서 강관과 콘크리트 부착응럭의 해석기법 개선에 관한 연구)

  • Seok, Keun-Yung;Ju, Gi-Su;Choi, Joon-Young;Chae, Seoung-Hun;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.83-90
    • /
    • 2007
  • Buildings become high and large. CFT(Concrete Filled steel Tube) columns have been developed to manage effectively that loads which columns support and cross sections of columns are increased. Because CFT column is the composite structure made of two different materials, many researches have been performed to look into mechanical behaviors. This study is an analytic study about bond stress on interface between concrete core and steel tube in circular and rectangular CFT columns. ABAQUS/Standard Version 5.8 is used to analyze bond stress by bond form and position of shear-connector, and improved analystic method about mechanical characters on interface is suggested.

  • PDF

Safety Evaluataion of Mega-frame Systems (메가프레임 시스템의 구조 안전성 평가)

  • Jung, Min-Kang;Park, Jong-Yeol;Kim, Jin-Koo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.400-403
    • /
    • 2010
  • Mega-frame 시스템은 구조적으로 횡력에 가장 효율적으로 저항할 수 있는 구조시스템으로서 200층 이상의 극초고층 건물에 적용되고 있다. 소수의 대형 기둥에 의하여 지지되므로, 기둥의 파괴로 인한 연쇄붕괴의 가능성이 매우 높다. 본 논문에서는 비선형 정적해석을 통하여 다양한 Mega-frame 구조물의 연쇄붕괴 저항능력을 평가해 보았다. 그 결과, Mega-frame 구조물의 연쇄붕괴 거동을 이해하고 이에 합당한 연쇄붕괴 보강방안을 찾으려 한다.

  • PDF